0% found this document useful (0 votes)
2K views7 pages

3 CFVV Vs VFVV PDF

This document discusses constant flux variable voltage (CFVV) and variable flux variable voltage (VFVV) control in transformers. CFVV control involves changing the number of turns on the primary winding to vary the secondary voltage while keeping flux constant. VFVV control involves changing the number of turns on the secondary winding, which causes flux to vary along with the secondary voltage. CFVV control maintains a constant ratio of voltage to turns, while this ratio does not remain constant under VFVV control. CFVV control is implemented using an on-load tap changer, while VFVV control uses an off-load tap changer.

Uploaded by

Pruthvi Krishna
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
2K views7 pages

3 CFVV Vs VFVV PDF

This document discusses constant flux variable voltage (CFVV) and variable flux variable voltage (VFVV) control in transformers. CFVV control involves changing the number of turns on the primary winding to vary the secondary voltage while keeping flux constant. VFVV control involves changing the number of turns on the secondary winding, which causes flux to vary along with the secondary voltage. CFVV control maintains a constant ratio of voltage to turns, while this ratio does not remain constant under VFVV control. CFVV control is implemented using an on-load tap changer, while VFVV control uses an off-load tap changer.

Uploaded by

Pruthvi Krishna
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 7

CFVV vs VFVV

Transformer action
 Transformer equation V= 4.44 Ø f N Eqn -1
• Where E= Induced voltage
• Ø = Max flux.
• F= frequency
• N = number of turns

 From eqn-1: Ø = V/4.44 f N


This means that flux is directly proportional to voltage
and inversely proportional to number of turns and
frequency.
Transformer Action

 Also N1/N2 = V1/V2 Eqn-2


 From this equation it can be equated that V1/N1
equals V2/N2.
 This means that the voltage per turn in a
transformer remains same throughout irrespective
of primary or secondary winding.
Voltage changing
 In order to vary the secondary voltage of
transformer we have two options
a) Change the number of turns of primary
b) Change the number of turns of secondary
 To increase the voltage on the secondary we
have to either increase the no of turns on
secondary side or decrease the number of turns
on primary side.
Changing the turns on primary side
On Load Tap Changer

 When the turns are changed on primary side, due


to variation of incoming voltage on primary side,
the control is called constant flux variable voltage
control.
 Because under this condition, due to decrease in
incoming voltage, the number of turns are on
primary side are decreased in order to increase
the secondary voltage.
 So in this case, (Ø = V/4.44 f N) the ratio of V/N
remains constant .
Changing the turns on Secondary
side
Off Load Tap Changer
 When the turns are changed on secondary side,
due to variation of incoming voltage on primary
side, the control is called variable flux variable
voltage control.
 Because under this condition, due to decrease in
incoming voltage, the number of turns are on
Secondary side are increased in order to increase
the secondary voltage.
 So in this case, (Ø = V/4.44 f N) the ratio of V/N
does not remain constant .
Thank you