CMP CTS (En)
CMP CTS (En)
Thank you
¥ Thank
• you for
for purchasing
purchasing COMMAX
COMMAX products.
products.
Please carefully
¥ Please
• carefully read
read this
this User’s
User’s Guide
Guide (in
(in particular,
particular, precautions
precautions for
for safety)
safety) before
before using
using aa product
product and
and follow
follow
instructions to
instructions to use
use aa product
product exactly.
exactly.
The company
company is is not
not responsible
responsible for
for any safety
¥ The
• any? 62 accidents
safety accidents
? caused
caused by
by abnormal
abnormal operation
operation of
of the
the product.
product.
Table of Contents
1. Greeting......................................................................................................................................1
2. Safety Warning & Caution ..........................................................................................................2
3. Parts ...........................................................................................................................................4
4. Password type ...........................................................................................................................8
5. How to input Password ..............................................................................................................9
6. Check house Password............................................................................................................12
7. Set building Number and ID to Lobby panel ...........................................................................13
8. Setting the Direct Call option....................................................................................................15
9. How to set the direct Call number ............................................................................................16
10. RF card key appliances..........................................................................................................17
11. Door release by internal information forwarding to SecuMAX way ........................................26
12. Door opening hours setting ....................................................................................................27
13. Line-by-line Call function Setting ...........................................................................................28
14. Call Tones selection ..............................................................................................................29
15. Setting the Number of Call Ring Repetitions..........................................................................30
16. Door release by external information forwarding to SecuMAX way ......................................31
17. Set to be forced opening the Main Entrance door by SecuMAX ............................................32
18. Selecting the Wiring Method .................................................................................................33
19. How to set the Video Floor Distributor(or CDV Converter) data ............................................34
20. Video Out Impedance Adjustment Setting ...........................................................................36
21. Registration of Household Unit Number ................................................................................37
22. Checking Videophone Status of Household Units ................................................................39
23. Setting the Keypad LED Option ..........................................................................................40
24. Activation of Electronic Key (Password) Function .................................................................41
25. Setting the Volume of Voice and Beep Sound .......................................................................42
26. Method of name data sending................................................................................................43
27. How to receive the name of the data......................................................................................44
28. How to set the Audio Floor Distributor data ...........................................................................46
29. Setting the door release by building password ....................................................................48
30. When you want to Call a household.......................................................................................50
31. When you want to Call a Guard Station ................................................................................52
32. Door Release by Unit Password ...........................................................................................53
33. Supplement (summary of various Programs) ........................................................................54
34. Wiring Information ..................................................................................................................56
35. Install Information ..................................................................................................................59
36. Part list ...................................................................................................................................59
37. Specifications and Features ..................................................................................................60
38. RF-ID Model (Optional) .........................................................................................................60
1. Greeting
* Thank you for purchasing a COMMAX product
* This product is a high tech Main Entrance interphone that supports electronic
Please read this manual carefully.
1
2. Safety Warning & Caution
Please follow the things described below in order to prevent any
danger or property damage.
Prohibition.
No touch
Caution
Shows plugging out the power cord
It may cause a minor damage or without an exception
injury if violated.
Shows the warning and caution for an electric shock.
Warning
Please don’t use several Please don’t bend the power Please don’t handle the power Please plug out the power
products at the same time on cable excessively or it may cable with a wet hand. cable from the socket when
one power socket. cause an electric shock. ·It may cause an electric not using it for a long period
·It may cause a fire due to an ·fire when using a damaged shock. of time.
abnormal overheating. power cable. ·It may shorten the product
lifespan or cause a fire.
Power & Installation
Please don’t install the Please don’t install the Please don’t use and connect When installing the product
product in the place where product with the lightening this product with other that generates heat, please
there is much oil, smoke or and thunder. products with different rated install the product away from
humidity. ·It may cause an electric voltage the wall (10cm) for the
·It may cause an electric shock or fire. ·It may cause a disorder or ventilation.
shock or fire. fire. ·It may cause a fire due to
the increased internal
temperature.
2
Warning
Please don’t disassemble, If an abnormal sound, burning Please don’t insert any Please use only the designated
repair or rebuild this product smell or smoke is coming out metallic or burnable materials batteries for the products of
arbitrarily (please contact the of the product, please plug out into the ventilation hole. using DC power.
Cleaning & Use
service center if a repair is the power cable and contact a ·It may cause an electric ·It may cause an electric
needed. service center. shock or fire. shock or fire.
·It may cause an electric ·It may cause an electric
shock or fire. shock or fire.
Caution
Please plug the power cable Please hold the plug tightly When connecting the power When installing the product,
firmly into the inner end when unplugging the power cables after cutting the cable, please fix it firmly while using
·It may cause a fire. cable (a part of the copper please install the product with the wall-mounting unit and
wire may be disconnected if power off screws.
the grabbing is only made on ·It may cause an electric ·It may cause an injury from
the cord when pulling out the shock or fire the falling object.
cable).
·It may cause an electric
shock or fire
Power & Installation
Please be careful when using Please check the use voltage Please avoid direct rays of the Please don’t install the
an AC circuit breaker since and current for the DC-only sun or heating devices at a product on an unstable place
there is a possibility of an products and use the time of installation. or small support board.
electric shock. appropriate rectifier. ·It may cause a fire. ·It may cause an injury if it
·It may cause a fire. falls down while in use.
When cleaning the product, Please don’t drop the product Please use the designated
please rub it with a soft and on the ground and don’t apply connection cable within the
dry cloth after plugging out a shock . maximum calling distance
Cleaning & Use
the power cable. (Please don’t ·It may cause a failure. designated for the product
use any chemical products ·It may reduce the product
such as wax, benzene, alcohol performance.
or cleanser.)
3
3. Parts
3-1. The name of parts
4
3-2. Important function
5
✽ Electric key & UP Button (K : Key)
1) Open door by Password Number.
(Deactivate Password LOCK function only.)
2) Move Up(In Program Mode)
6
✽ Reset Button
Reset security guard password or management office password.
When forgot password, press reset Button which is on back side of products 15
2) If password is forgotten,
2-1. Password for any household:
Use the identifying household password function (6-1) to confirm the
password (methods to confirm password shall be requested to the
Management office or Security Press).
2-2. Password for any building:
Reset the password by using Management password
2-3. Password for Management
Press "Reset Button".
The password will be reset to factory default.
3) Deleting All RF Card Keys function in "8-5" shall ONLY be used when the
product is initially installed.
7
4. Password type
4-1. Password for the Management Office ("Management Password")
A password for the Manager
Factory default for the Manager Password is 4321.
<Reference>
* "P": Program Button * "K": Electronic Key Button * "E": Call Button
※ Previous Password
Default password for Management Password is 4321
Building Password is 1234
Unit Password is 1234
※ New Password
The password newly set.
8
5. How to input Password
5-1. Press management Password
• P - old Password - E - 0 - E - New Password - E
• Password must be 4 digits.
•"0000", "1234", "4321" can't be used as Password
<Caution>
Please do not keep the factory default password. New password setting
after the installation is strongly recommended.
9
5-2. Press building Password
• P - old Password - E - 1 - E - New Password - E
• Password must be 4 digits.
• "0000", "1234", "4321" can't be used as Password
10
5-3. Press house (Unit) Password
• K - 20 - E- house Number - E- old Password - E - New Password - E
• Password must be 4 digits.
• "0000", "1234", "4321" can't be used as Password
• Unit Password no. may not be changed because of Interphone types.
(Some model of Interphone can change Password in house. Please, check manual of
interphone)
11
6. Check house Password
6-1. Check house Password
• P - management Password - E - 16 - E - Household Unit Number - E
12
7. Set building Number and ID to Lobby panel
• This setting is mandatory because building Number and ID automatically are set up
when lobby panel Call house and security guard.
• Max. 99 lobby panel can be installed for one building.
13
7-2. Set ID no. in Lobby Panel
• P - Management Password - E - 3 - E - ID - E
14
8. Setting the Direct Call option
• P - Management Password - E - 24 - E - 0 - E : Direct Call number only
• P- Management Password - E - 24 - E - 1 - E : Direct Call number + Call button
• This function is to set the option to call household using Direct Call number.
15
9. How to set the direct Call number
• P - Management Password - E - 4 - E - Household number - E
• This function is to set the direct call number
16
10. RF card key appliances
10-1. RF card key test way
• P- Management Password - E - 9 - E - Card Test - X(Cancel)
• This function is only for the test of wireless card key
17
10-2. RF card key input way
• P- Management Password - E - 10 - E - Place card close to the RF/ID receiver - X(cancel)
<References>
Up to 2048 cards can be registered(if not to connect with SecuMAX)
18
10-3-1. RF card key separate deletion way
• P- Management Password - E - 12 - E - Delete cards - X(Cancel)
19
10-3-2. RF card key separate deletion way
• P - Management Password - E - 12 - E - Identification number - X(Cancel)
20
10-4. RF card key registration check way
• P - Management Password - E - 13 - E - Delete cards - X(Cancel)
21
10-5. RF card key all delete way
• P- Management password - E - 11 - E - E
• All deletion way is only useful when initially set up, unless all registered cards are to
be deleted.
<References>
All numbers can be deleted only if the mode"1" in the Program
number(23) is selected & executed the all delete process within 30
seconds.
22
10-6. RF card key capacity change way
• P- Management password - E - 19 - E - 0 - E : Up to 2048 RF Cards can be registered
• P- Management password - E - 19 - E - 1 - E : Unlimited RF Cards can be registered )
23
10-7. RF card key data transmission
• P - Management Passwords - E - 32 - E - Press destination lobby phone number - E
<References>
•Data can be sent only if the mode "99" in the Program number(23) is
selected & executed the process within 30 seconds.
•You cannot use any other function before it completes(It takes about 5
minutes).
If you want to complete more quickly, use the download Program.
24
10-8. RF card key data reception
• P - Management Passwords - E - 33 - E - Press source lobby phone number - E
<References>
•Data can be received only if the mode "99" in the Program number(23)
is selected & executed the process within 30 seconds.
•You cannot use any other function before it completes(It takes about 5
minutes).
If you want to complete more quickly, use the download Program.
25
11. Door release by internal information forwarding to
SecuMAX way
•P - Management password - E - 22 - E - 0 - E : Forwarding to SecuMAX disabled
•P - Management password - E - 22 - E - 1 - E : Forwarding to SecuMAX enabled
•This function is to set the door release by internal sensor information forwarding to
SecuMAX.
26
12. Door opening hours setting
•P- Management Passwords - E- 5 - E - Opening hours - E
•This function is to control the common entrance door opening hours.
27
13. Line-by-line Call function Setting
•P - Management password - E - 21 - E - 0 - E : available for entire house call
•P - Management password - E - 21 - E - Line number - E : Call only specified line ex) In
case 1 line ~ 2 line, input "0102".
•This function is only for specified line call, not for entire house call
28
14. Call Tones selection
•P - Management password - E - 7 - E - 0 - E : Melody sound
•P - Management password - E - 7 - E - 1 - E : Bell(Ringer sound)
•This function is to set the recall sound of house & guard station at the common entrance.
29
15. Setting the Number of Call Ring Repetitions
•P - Management Password - E - 25 - E - 0 - E : Continuous call ring enabled.
•P - Management Password - E - 25 - E - 1 - E : 1 time call ring enabled.
•This function sets number of call ring repetition when a call is made to any households or
security office.
30
16. Door release by external information forwarding
to SecuMAX way
•P - Management password - E - 18 - E - 0 - E : Forwarding to SecuMAX disabled
•P - Management password - E - 18 - E - 1 - E : Forwarding to SecuMAX enabled
•This function is to set door release by external sensor information forwarding to SecuMAX
31
17. Set to be forced opening the Main Entrance door
by SecuMAX
•P - Management password - E - 29 - E - 0 - E : Forced opening by SecuMAX disabled
•P - Management password - E - 29 - E - 1 - E : Forced opening by SecuMAX enabled
•This function is to set the opening the Main Entrance door forced opening by SecuMAX
32
18. Selecting the Wiring Method
•P - Management Password - E - 6 - E - 4 - E : common 4 wire method
•P - Management Password - E - 6 - E - 6 - E : common 6 wire method
•If common 6 wire method selected, there will be no video signal sent to all household
units.
33
19. How to set the Video Floor Distributor
(or CDV Converter) data
•P - Management Password - E - 36 - E - Module ID - E - Setting the data - P
•This function is to set household data of the video floor distributor or CDV converter when
it is installed.
•Please, Refer to the manual of the video floor distributor or CDV converter if you want to
know about more detailed functions.
34
① Press Program Button "P".
② Press Management password.
③ Press Call Button "E".
④ Press "36" (Program Number).
⑤ Press Call Button "E".
⑥ Enter the Module ID.
⑦ Enter the household number, password and Monitoring Lobby ID.
- If you want to move cursor, Press the Searching Button(S)
⑧ Press Call Button "E".
⑨ If you want to move page, Press the Up(K) & Down(G) Button.(Setting the other number)
- Repeat ⑦ & ⑧ procedures.
⑩ Press Program Button "P" after finish to set all number
- Please, wait to complete upload.
<References>
•Data can be received only if the mode "99" in the Program number(23)
is selected & executed the process within 30 seconds.
•You cannot use any other function before it completes(It takes about 1
minutes).
※ The following registration method is applicable to other systems EXCEPT the MODUM system,
for example Gateview System or RS-481 System.
35
20. Video Out Impedance Adjustment Setting
•P - Management Password - E - 8 - E - 0 - E : Short distance transmission.
•P - Management Password - E - 8 - E - 1 - E : Long distance transmission.
•Factory default is set as "short distance transmission".
36
21. Registration of Household Unit Number
•P - Management Password - E - 15 - E - Call Security from the monitor.- number of
household - E - serial number - E
•This method applies to the case that there is no security station installed. Calling security
from the monitor will direct the call to the lobby phone. Household Unit Number can be set
at the lobby phone.
37
① Press Program Button "P".
② Press Management password.
③ Press Call Button "E".
④ Press "15" (Program Number).
⑤ Press Call Button "E".
⑥ From a household unit, Call security. The factory default household unit number appears on
the OLED display of the lobby phone. Please Press the actual unit number.
⑦ Press the actual unit number and press Call Button "E".
⑧ Press "0" (0 is Master lobby phone number. If multiple lobby phones are installed, please
Press the corresponding lobby phone number) and press Call Button "E".
⑨ On the OLED display, the unit number input mode appears.
⑩ By repeating 6, 7, 8, 9 procedures, other unit numbers can be registered.
⑪ As unit number registration is done press Cancel Button "X" to exit.
<References>
•Master-videophone's "Multi Sub Number" is number 0 (zero).
•Sub-videophone's "Multi Sub Number" is given between 1 and 4.
•Up to 4 videophones can be installed in a single household unit and
the "Multi Sub Numbers" shall not be overlapped.
•"Multi Sub Numbers" for sub-videophones shall be registered in
numerical order.
•At least one Master-videophone with "Multi Sub Number 0" must be
installed and if only one videophone is installed, it is considered as
Master-videophone (set as Multi Sub Number 0).
•In case that ADT-481 is installed, it does not register as Master unit.
•If sub-videophone is 485 system, its Master-videophone's Multi Sub
Number is 1 (one) and those of sub-videophones are between 2 and 4.
38
22. Checking Videophone Status of Household Units
•P - Management password - E - 14 - Unit Number - E - serial number - E
•This function is to check the status of videophones installed in each household unit.
39
① Press Program Button "P".
② Press Management Password.
③ Press Call Button "E".
④ Press "14" (Program Number).
⑤ Press Call Button "E".
⑥ Press the Unit Number and press Call Button "E".
⑦ Press "0" (number zero as Master lobby phone or Press a corresponding lobby phone
number) and press Call Button "E". Status of the household unit appears (Please refer to
below for the status).
⑧ To check another unit status, repeat 6 & 7 procedures.
⑨ As the status check is done press Cancel Button "X" to exit.
40
23. Setting the Keypad LED Option
•P - Management Password - E - 20 - 0 - E : Keypad LED OFF?
•P - Management Password - E - 20 - 1 - E : Keypad LED ON
•This function is to set keypad LED ON/OFF.
41
24. Activation of Electronic Key (Password) Function
•P - Management Password - E - 31 - 1 - E : Electronic Key (Password) enabled.
•P - Management Password - E - 31 - 0 - E : Electronic Key (Password) disabled.
•This function is to enable or disable the password access.
42
25. Setting the Volume of Voice and Beep Sound
•P - Management Password - E - 30 - E - Beep Volume (1~2) - Voice Volume (1~7) - E
•This function enables the adjustment of Beep & Voice volume.
<References>
•Beep sound volume applies to paging tone and Button sound tone.
43
26. Method of name data sending
•P - Management Password - E - 34 - E - Press destination lobby phone number - E
<References>
•Data can be send only if the mode "99" in the Program number(23) is
selected & executed the process within 30 seconds.
•You cannot use any other function before it completes(It takes about 5
minutes). If you want to complete more quickly, use the download
Program.
44
27. How to receive the name of the data
•P - Management Password - E - 35 - E - Press source lobby phone number - E
<References>
•Data can be send only if the mode "99" in the Program number(23) is
selected & executed the process within 30 seconds.
•You cannot use any other function before it completes(It takes about 5
minutes). If you want to complete more quickly, use the download
Program.
45
28. How to set the Audio Floor Distributor data
•P - Management Password - E - 36 - E - Module ID - E - Setting the data - P
•This function is to set household data of the audio floor distributor when it is installed.
•Please, Refer to the manual of audio floor distributor if you want to know about more
detailed functions.
46
① Press Program Button "P".
② Press Management password.
③ Press Call Button "E".
④ Press "36" (Program Number).
⑤ Press Call Button "E".
⑥ Enter the Module ID.
⑦ Enter the household number, password and DTMF setting value.
- If you want to move cursor, Press the Searching Button(S).
⑧ Press Call Button "E".
⑨ If you want to move page, Press the Up(K) & Down(G) Button.(Setting the other number)
- Repeat ⑦ & ⑧ procedures.
⑩ Press Program Button "P" after finish to set all number
- Please, wait to complete upload.
<References>
•It's able to set the DTMF setting value when audio floor distributors
with DTMF function are installed.(ex. CCU-232AGF)
•DTMF setting value '0' : The function of DTMF is disabled.
DTMF setting value '1' : The function of DTMF is enabled.
<References>
•Data can be received only if the mode "99" in the Program number(23)
is selected & executed the process within 30 seconds.
•You cannot use any other function before it completes(It takes about 1
minutes).
47
29. Setting the door release by building password
29-1. Setting the Door Release by Building Password (Refer to 4-2)
• "P" - Management Password - "E" - 28 (number twenty-eight) - 1 (number one) -"E":
Door release by Building Password enabled.
•"P" - Management Password - "E" - 28 (number twenty-eight) - 0 (number zero) - "E" :
Door release by Building Password disabled.
•This function enables the door release by Building Password.
•This function provides least security to the access of the entrance since the password
is being shared among number of people. Please keep the security ilding Password
strictly and/or change the Building Password periodically.
48
29-2. Using a door release by Building Password function.
49
30. When you want to Call a household
1) Called to a household
50
If Program '24' is set by '1'
51
31. When you want to Call a Guard Station
1) Call by Searching name
52
32. Door Release by Unit Password
53
33. Supplement (summary of various Programs)
Setting Passwords
1. P–Previous Management Password–E–0–E– New Management Password–E: Management
Password Registration.
2. P-Previous Building Password-E-1-E-New Building Password-E : Building Password
Registration
3. K-20-E-Household Unit Number-E-Previous Unit Password-E-New Unit Password-E : Unit
Password Registration
4. P-Management Password-E-16-E-Unit Number-E : Retrieving Unit Password
Building number, Lobby phone number, and Door release function Settings
1. P-Management Password-E-2-E-Building Number-E : Building Number Registration
2. P-Management Password-E-3-E-Lobby Phone Number-E : Lobby Phone Number
Registration
3. P-Management Password-E-28-E : Door Release Function enabled/disabled (00: Disabled,
01: Enabled)
4. P-Management Password-E-31-E : Electronic Key (Password) enabled/disabled (00:
Disabled, 01: Enabled)
SecuMAX Management
1. P-Management Password-E-18-E : Set to Door release by external information forwarding to
SecuMAX.
2. P-Management Password-E-22-E : Set to Door release by internal information forwarding to
SecuMAX.
54
3. P-Management Password-E-29-E : Set to be forced opening the Main Entrance door by
SecuMAX.
How to make a unit Call and guard station Call from a lobby phone
1. Press house number-E : to Household
2. S-Name Search-E : to Household
3. Press Number ‘9999’-E : to Guard Station
4. Name search-Select Guard-E : to Guard Station
Other settings
1. P-Management Password -E-5-E : Door Release Duration Setting
2. P-Management Password -E-6-E : Selecting Wiring Methods
(04 : Common 4 wires, 06: Common 6 wires)
3. P-Management Password -E-7-E : Selecting Call Rings (00:MELODY, 01:BELL)
4. P-Management Password -E-8-E : Setting Video Out Impedance
(00: Short range, 01: Long range)
5. P-Management Password -E-20-E : Setting the Keypad LED Option
(00 : Only work when you used lobby phone)
(01 : Always On)
6. P-Management Password -E-20-E : Setting the Keypad LED Option
(00 : Only work when you used lobby phone)
(01 : Always On)
7. P-Management Password -E-21-E : Setting the Call by Unit Line
8. P-Management Password -E-25-E : Setting number of Call Rings
(00 : continuous, 01: once)
9. P-Management Password -E-30-Beep Volume-Voice Volume-E :
Setting the Volume of Voice and Beep Sound
10. P-Management Password -E-24-E : Setting the Direct Call Option
(00 : Press Direct Call number only)
(01 : Press Direct Call number + Call button)
11. P-Management Password-E-4-E-Household number-E : Setting the Direct Call number
12. P-Management Password-E-36-E-Module ID-E-Setting Data-P : Setting the CDV-Converter
55
34. Wiring Information
1) Guard interphone
① GateView Guard Station
56
③ Sensor connection method
④ Extension Panel
<Caution>
•You can use both 2 and 4 rows panel(CMP-2BX/4BX) for extending but
can’t use together. (MAX. 5 units)
57
⑤ Entrance interphone (CMP-CTS)
⑥ System schematic
58
35. Install Information
<Caution>
•1) If installed outdoor, it requires extra molding for water-proof and
rainshield.
2) Recommanded height is pertinent from 1450mm ~ 1500mm
59
37. Specifications and Features
Installation Flush Mount Type installation
Model CMP-CTS
Gateview System (UTP Cable)
Household unit monitor (8 wires-common 6
Wiring
wires+video 2 wires),
Security station phone (common 4 wires)
Power Source DC 12V, 1A
Power Consumption Standby : 82mA, Maximum : 276mA
Call Method Handsfree (one way)
Image Sensor Color CMOS(Pinhole Type)
Horizontal/Vertical 15,735KHz / 60Hz,
Scanning Frequency 15,625KHz / 50Hz
Imaging Angle Horizontal : 62 degrees, Vertical : 46 degrees
Lowest Intensity of
0.1 Lux (up to 300mm from the camera)
Illumination
Effective Call Range UTP CAT. 5e, 300m
RF Sensing Range 30mm
Lighting Built-in LED light for night use
Temperature -40°C(tested up to -40°C ) ~ 40°C
Dimensions 130 (W) x 249 (H) x 38 (D) mm
60
513-11, Sangdaewon-dong, Jungwon-gu, Seongnam-si, Gyeonggi-do, Korea
Int’l Business Dept. Tel. : +82-31-7393-540~550 Fax. : +82-31-745-2133
Web site : www.commax.com
PM98CTS00010 Printed In Korea / 2015.09.104