Liebert AF3
Next Generation Active Harmonic Filter
Ratings Available
30, 60, 100, 150, 300 A
Harmonics - An Overview
You Need To Be Aware Of Harmonics
During the last few years industries has witnessed an increasing awareness of clean power, power system harmonics and
associated problems in low-voltage systems, both in power utilities and consumer segment. Harmonics being one of the
major contributors of poor power quality, a better understanding is essential to minimize its effects.
What are Harmonics?
Harmonics are periodic, sinusoidal & integer multiples of fundamental
frequency (50 or 60Hz), current or voltage components, present in
nonsinusoidal waveform.
It distorts pure sinusoidal waveform and turns it to a non-sinusoidal
waveform.
Current Harmonics are Load generated components and usually have effect
on Voltage waveform and make it non-sinusoidal.
Voltage Harmonics are predominantly by-products of current harmonics
except for few occasions, where a power is generated out of DC voltages or
low capacity generators.
Harmonics can only be measured by electronic measurement devices
Effect of Harmonics:
Overheating of Generator, motor, transformer.
Overvoltage conditions on supply system.
Increased transformer losses (need to over-size)
Nuisance tripping of circuit breakers
Improper operation of microprocessor-based equipment
Overheating and possible resonance with capacitors
Re-injection of harmonic currents into the utility network.
Neutral burnout.
Insulation breakdown.
Does Your Facility Have A Harmonics Problem?
Todays Modern Offices, Data centers and Manufacturing plants often faces unique problems which leads to loss of
Business Critical Continuity. Some of commonly faced problems are:
Transformers getting overheated while supplying seemingly average loads
Audible noise / hum in transformers.
Significant Transient activity in supply system
Decreasing distribution capacity due to hot cables
Excessive N-G voltages
Neutral conductors in 3-Phase balanced circuits getting overheated and / or burnt
Circuit breakers are tripping for no apparent reason
Failure of PF improvement capacitors
Interference in telecommunication equipments
Generator Hunting
Electronic Control Clock errors
Quivering Monitors and CRT displays
Supply Voltage distortion and lagging power factor.
And many more
Yet, the standard trouble shooting procedures show everything to be normal !
Which Equipment in your facility is responsible?
Harmonics are the by-products of Modern facilities and Electronic equipment.
These are called often called non-linear loads. Examples of such loads are:
Servers, Computers, PCs, Printers and other IT Equipment
(Having Switch Mode Power Supplies)
Controlled Rectifiers, Battery Chargers, Uninterrupted Power Supply
(UPS) systems
Phase controlled AC voltage regulators
Compact Fluorescent Lamps, Fan regulators
Traction Equipment
Arc Furnaces or Induction Furnaces, Welding Machines
Adjustable Speed AC and DC Variable speed motor drives
PLC, DCS and SCADA systems (SMPS)
Solid State Heater Controls
HVDC sending and receiving end equipment
Flow of Harmonics
In an electrical system, the harmonics are not typically generated in the generator except in case of small generators.
If by chance the supply system has harmonics, then on a linear load (purely resistive, capacitive & inductive load),
there will be harmonic currents produced in the load. Under these conditions, direction of flow of the harmonic
power is then downstream.
On the contrary, even if the supply voltage is purely sinusoidal and of fundamental frequency (50 Hz or 60Hz) and
the load is nonlinear, harmonic currents are generated and due to the line impedance harmonic voltages are
developed at the distribution end. Under these conditions the harmonic power flows upstream.
AF3 - Next Generation Active Filter
OPERATING PRINCIPLE
Without Active Filter
THDi = 27.4% PF = 0.87
Only Harmonic Correction
THDi = 4.0% PF = 0.92
PF + Harmonic Correction
THDi = 3.9% PF = 1.00
Features:
Synchronous Rotating Reference Frame principle
32 bit, DSP control
PF compensation, leading as well as lagging
Load Balancing
Employees high speed IGBTs in power circuit
Internal CAN Communication
Closed loop active filter with source current sensing
High attenuation up to 96 % of individual harmonics
Programmable selective harmonic elimination
Required PF can be set from 0.7 to unity
Selection between PF and harmonic compensation
Remote monitoring and diagnosis
Self current limiting, under overloading condition
Automatic current limit modification with respect to
ambient temperature
Alarm log with date and time stamp for fault diagnosis.
User friendly PC Interface
CE Marking
Value to customer
Improves reliability of the electrical system, reduces
cable and transformer losses.
Better utilization of distribution Transformer &
Generator
Increases efficiency, capacitor life, PF, uptime.
Freedom From Harmonic Pollution
Application area
At the input side of Rectifier, AC Drive, UPS Harmonic & PF Compensation
To reduce harmonics and improve power
factor of UPS, rectifiers, AC & DC drives etc.
To improve PF of motor loads
(i.e. inductive loads)
Can be used at the output of UPS,to reduce
harmonic effects on UPS and increase
available capacity. UPS will supply only
fundamental and active power.
Can be used as Hybrid filter
I.e. it can be used along with Passive filter &
capacitor filter, resulting in reduction of
cost and rating of active filter.
PF Compensation
A single unit can be used
at the input of multiple UPS
E.g.60 A filter is sufficient
for 160 KVA Hipulse UPS
and the same can be used for
4 nos of 40 KVA.
At the source input
Intuitive HMI & Communication
Connectivity Diagram
OLED based graphic display showing
Harmonic spectrum upto 64 th harmonic of load & line current.
True measurement of Input/output voltage ,current,Kva,kw,pf.
Waveform-Showing real time display visual of input current,
load current & Input voltage.
Harmonics & pf configuration.
Load Current Remote monitoring & Diagnosis
All front display parameters including waveforms can be monitored
through PC.
Supports MODBUS protocol.
Potential free contacts for monitoring the status of filter.
Inbuilt SNMP & HTTP support*
*optional
Harmonic Spectrum
SPECIFICATION
Model AF3 30 AF3 60 AF3 100 AF3 150 AF3 300
Note: Specification & designs change from time to time, please ask for confirmation of the information given in the brochure.
Country Office Toll Free No 18002096070