Wuy 1.43 KN/M

The document calculates design load combinations and bending moments for a structural member. It then calculates the bending capacity of the member (ΦbMpx and ΦbMpy) and verifies that the calculated bending moments are less than the bending capacity, indicating the member is safe. It also lists bar forces calculated from a roof truss analysis to design the top, bottom and web members using L50x50x5 sections.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as DOCX, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
103 views3 pages

Wuy 1.43 KN/M

The document calculates design load combinations and bending moments for a structural member. It then calculates the bending capacity of the member (ΦbMpx and ΦbMpy) and verifies that the calculated bending moments are less than the bending capacity, indicating the member is safe. It also lists bar forces calculated from a roof truss analysis to design the top, bottom and web members using L50x50x5 sections.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as DOCX, PDF, TXT or read online on Scribd
You are on page 1/ 3

Design Load Combination

Wuy = 1.2 DL + 1.6 LL+ 0.5W

= 1.2 (0.2424 kN/m) + 1.6 (0.75 kN/m) + 0.5(-0.13 kN/m)

Wuy =1.43 kN/m

Wux = 1.2 DL + 1.6 LL

= 1.2 (0.07kN/m) + 1.6 (0.22 kN/m) + 0.5(-0.42 kN/m)

Wuy =0.23 kN/m

Normal Bending Moments

Maximum Moment about X- axis


𝑊𝑢𝑥𝐿2 )
𝑀𝑢𝑥 = 8

(0.23𝑘𝑁/𝑚)(5𝑚)2 )
𝑀𝑢𝑥 = 8

Mux = 0.72 kN.m

Maximum Moment about Y- axis


𝑊𝑢𝑥𝐿2 )
𝑀𝑢𝑦 = 8

(1.43 𝑘𝑁/𝑚)(5𝑚)2 )
𝑀𝑢𝑦 = 8

Muy = 1.12 kN.m

Compute for ΦbMpx:

ΦbMpx = (0.90) (248 x) (45 x 103 mm3)

ΦbMpx = 10.044 kN-m

Compute for ΦbMpx:

Since the load is applied at the top flange, use only half of the capacity to
account for torsional effects.

ΦbMpx = (0.90) (248MPa) (3.50 x 10-5 m3)


ΦbMpy = 7.812 kN-m

Compute for ΦbMpy:

Since the load is applied at the top flange, use only half of the capacity to
account for torsional effects.

ΦbMpy = (0.90) (248MPa) (4.40x 10-5 m3)

ΦbMpy = 4.91 kN-m

Using expression:

Mux/ ΦbMpx + Muy /ΦbMpy < 1.0

0.72𝑘𝑁.𝑚 1.12𝑘𝑁.𝑚
+ = 0.32 < 1.0 − 𝑺𝑨𝑭𝑬
7.812 𝑘𝑁.𝑚 4.91𝑘𝑁.𝑚

Therefore use LC 100x50x2 Purlins


b. Design of the Top, Bottom, and Web members

Bar Forces from Roof Truss Analysis

TRUSS MEMBER FORCE


AC = BG 68.11 kN (T)
AD = BF 19.09 kN (T)
AI = BH 46.88 kN (C)
DI = FH -
DJ = FJ 8.09 kN (C)
DE = FE 8.19 kN(C)
IJ = HJ 46.88 kN (C)
EJ -

Using L50x50x5 Top, Bottom Chord and Web Members

Properties L90x90x6
Weight (kg/m) 8.30
Area (mm2) 1056.98
Depth (mm) 90
Width (mm) 90
Thickness (mm) 6
I (103 mm4) 803.2
S (103 mm3) 12.2
r (mm) 27.57
x or y (mm) 24.05

𝑘𝐿 0.5 (5.025𝑚)(1000𝑚𝑚)
= = 91.13
𝑟 27.57𝑚𝑚

2𝜋𝐸 2𝜋(200𝑥109 )
𝐶𝑐 = √ = √ = 126.17
𝐹𝑦 248𝑥106

You might also like