0% found this document useful (0 votes)
5K views9 pages

Concrete Mix Design Excel Software

1) The document provides a concrete mix design for grade M25 concrete with a target compressive strength of 25 MPa. 2) It specifies the materials required per 1 cubic meter of concrete including 422.73kg of cement, 565.72kg of fine aggregate, 709.71kg of 20mm coarse aggregate, and 473.14kg of 10mm coarse aggregate. 3) The water-cement ratio is 0.44 and the expected slump is 75-100mm.

Uploaded by

ramkrishna
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLSX, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
5K views9 pages

Concrete Mix Design Excel Software

1) The document provides a concrete mix design for grade M25 concrete with a target compressive strength of 25 MPa. 2) It specifies the materials required per 1 cubic meter of concrete including 422.73kg of cement, 565.72kg of fine aggregate, 709.71kg of 20mm coarse aggregate, and 473.14kg of 10mm coarse aggregate. 3) The water-cement ratio is 0.44 and the expected slump is 75-100mm.

Uploaded by

ramkrishna
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLSX, PDF, TXT or read online on Scribd
You are on page 1/ 9

Mix Design for Concrete Grade = M 25

C1.Design stipulation:
i Characteristic Compressive strength = 25 N/mm2
ii Maximum size of aggregate = 20 mm
iii Degree of workability = 0.8
iv Degree of quality = Good
v Type of Exposure = Mild

C2. Test data for materials


(i) Cement used = PPC
(ii) Specific gravity of Cement = 3
(iii) Specific gravity
Fine Aggregate = 2.8
Coarse Aggregate = 2.61
(iv) Water absorption
Fine Aggregate = 2.1 %
Coarse Aggregate = 0.78 %
(v) Free Surface Moisture
Fine Aggregate = 2.1 %
Coarse Aggregate = Nil %
(vi)
Fine Aggregate confirming the table 4, IS = 3 Zone
383- Zone

C3.Target mean strength


= 31.60 N/mm2

C4. Selection of Water Cement ratio


Water Cement ratio = 0.44 (From fig. 1, Is 10262)

C7. Determination of Fine & Coarse aggregate


Air entrapped in concrete = 2 % (From Table 3, IS 10262)
Actual quantity of concrete "V" = 0.98 Cum
Materials required for concrete
Grade M 25
Concrete quantity = 1 Cum
Sl. Material name Quantity Unit
No

1 Cement 422.73 kg
2 Fine Aggregate 565.72 kg
3 Coarse Aggregate 20mm 709.71 kg
4 Coarse Aggregate 10mm 473.14 kg
5 Water 183.63 ltr
6 Slump 75 - 100 mm
7 W/C ratio 0.44
Prepared by,

Sathiyaseela
+91 8894770272
Concrete Mix Design

1) Design Grade = 35
2) Target Mean Strength = 43.20

3) W/C Ratio = 0.48

4) Maximun Size of Aggregate = 20

5) Water Content per Cubic metre of Concrete = 186

6) Sand Content per Cubic metre of Concrete = 35

finenes Modulus = 3.5

Sand Confirming Zone = 4

Compaction Factor 0.9

7) Correction in water Content = 191.58

8) Correction in Sand Content = 29.6

9) Cement Content = 399.13

10) Specific Gravity of Cement = 3.15

11) Specific Gravity


1) Fine Aggregate = 2.65
2) Coarse Aggregate = 3.07

12) Moisture Content(%) 60


Axis Title

50

40
60
1) Fine Aggregate = 1.25

Axis Title
F.A
50
2) Coarse Aggregate = 0.85 C.A
40
13) Water absorption(%)
1) Fine Aggregate = 2 F.A 30
2) Coarse Aggregate = 0.65 C.A
20

10
14) Estimated Air Contain(%) = 2
0
0.3 0.35
15) Volume of Concretem^3) = 1 v
(c/Sc)
1/P
16)) Quantity of Fine Aggregate = 519.05 Kg 1/Fa

17) Quantity of Coarse Aggregate = 1430.15 Kg

18) Correction in Qty. of Fine Aggregate = 525.54 Kg

19) Correction in Qty. of coarse Aggregate = 1442.30 Kg

20) Correction in Qty. of Water = 192.61 Litre

Sr. No: Material Name Quantity(Kg)

1 Cement Content 399


2 Water 193
Fine Aggregate 526
3 1) White Sand 263
2) Black Sand 263
Coarse Aggregate 1442
4 1) Coarse Aggregate(20mm) 865
2) Coarse Aggregate(10mm Grit) 577
Slum of Concrete 50-100
CONCRETE MIX DESIGN AS PER IS : 10262 - 1982
w/c Strength w/c Strength
Grade Std. Deviation
0.42 48 0.49 29
M20 26.56 0.43 45 0.50 26
4
M25 31.56 0.44 43 0.51 25
M30 38.20 0.45 40 0.52 24
M35 43.20 0.46 38 0.53 23
5
M40 48.20 0.47 33 0.54 22
M45 53.20 0.48 31 0.55 21

w/c=0.60
Nominal max. Water ContentSand Content
Size of aggregate
10 208 40
20 186 35
40 165 30

Adjusted Required in
Change in Condition % of Sand
Water Content Content
For Sand Cofirming Zone 1
to grading zone- I, 0 zone 3 -3
II, or IV of IS : 383-
1970 Zone 4

Increase in
Compaction 3 W/C
Factor Ratio
0.3
0.35
Each 0.05 increase or 0.4
Decrease in free w/c -2.4
ratio(std=0.60) 0.45
0.5
Total 3 -5.4 0.55
0.6

Comp. Strength
60
Axis Title

50

40
Comp. Strength
60
Axis Title 6.488
50 18.644
12.16
40
Comp. Strength
30 10.38
19.68
9.30
20

10

0
0.3 0.35 0.4 0.45 0.5 0.55 0.6
980
126.7063492064
3.3783783784 1/(1-P) 1.4204545
0.3773584906 1/Sc 0.3257329

Mix Proportions By mass

Water Cement F.A C.A


192.613 399 526 1442
0.48 1 1.32 3.61

Quantities For 1 Bag of Cement

Water Cement F.A C.A


24.0 50 66 181

Quantity for 9 Cube

Water Cement F.A C.A


8.0 17 22 60

Prepared By: Mahaja Bhushan


AS PER IS : 10262 - 1982
Strength
10 54
20 46
30 37
40 31
50 26
60 21
70 18

You might also like