0% found this document useful (0 votes)
348 views5 pages

Circular Column Design Based On ACI 318-19: Input Data & Design Summary

This document summarizes the design of a circular column with a diameter of 20 inches based on ACI 318-19. The column has a factored axial load of 300 kips and a factored magnified moment of 140 ft-kips. The design meets all requirements for flexural and axial capacity, shear capacity, and slenderness effects. Calculations are provided for the column's factored axial capacity, moment capacity, shear capacity, and magnified moment. The column design is determined to be adequate based on the ACI 318-19 code requirements.

Uploaded by

JEEVENDRAN
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLSX, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
348 views5 pages

Circular Column Design Based On ACI 318-19: Input Data & Design Summary

This document summarizes the design of a circular column with a diameter of 20 inches based on ACI 318-19. The column has a factored axial load of 300 kips and a factored magnified moment of 140 ft-kips. The design meets all requirements for flexural and axial capacity, shear capacity, and slenderness effects. Calculations are provided for the column's factored axial capacity, moment capacity, shear capacity, and magnified moment. The column design is determined to be adequate based on the ACI 318-19 code requirements.

Uploaded by

JEEVENDRAN
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLSX, PDF, TXT or read online on Scribd
You are on page 1/ 5

PROJECT : PAGE :

CLIENT : DESIGN BY :
JOB NO. : DATE : REVIEW BY :
Circular Column Design Based on ACI 318-19

INPUT DATA & DESIGN SUMMARY e

CONCRETE STRENGTH fc' = 5 ksi, (34 MPa)


e
REBAR YIELD STRESS fy = 60 ksi, (414 MPa)
SECTION SIZE D = 20 in, (508 mm)
FACTORED AXIAL LOAD Pu = 300 kips, (1334 kN) e
FACTORED MAGNIFIED MOMENT Mu = 140 ft-kips, (190 kN-m)
FACTORED SHEAR LOAD Vu = 20 kips, (89 kN)
COLUMN VERT. REINFORCEMENT 8 # 6
LATERAL REINF. OPTION (0=Spirals, 1=Ties) 1 Ties
LATERAL REINFORCEMENT # 4 @ 12 in. (305 mm), o.c. THE COLUMN DESIGN IS ADEQUATE.

ANALYSIS
1000      2
 b f C'  2  e c    e c   , for 0  e c  e o e s E s , for e s  e ty
e
fC   e o   e o   , fS
800
 f , for e s  e ty
'  y
 b e f C , for e c  e o
600
f Pn (k) 
2 b e f C'  fy e ty , for compression controlled
eo  , e ty  , et  
e ty  0.003 , for tension controlled
400
Ec Es
'
200 E c  57 f C , E s  29000ksi , b e  0.85 , e cu  0.003

0
0 20 40 60 80 100 120 140 160 180 200 Note:
1. Between compression & tension controlled is
-200
Transition, which the f should be by linear
interpolation. (ACI 318-19 Tab. 21.2.2 & Fig. R10.4.2.1)
-400 2. ACI 318-19 changed f (Fig.R21.2.2b) and keeps
f Mn (ft-k) Solid Black Line - Tension Controlled be (22.2.2.4.1) and ecu (Fig. R21.2.2a) the same.
Solid Red Line - Transition But AISC 360/341-16 has different f (0.9 only) and
Dash Line - Compression Controlled be (1.0 or 0.7).

CHECK FLEXURAL & AXIAL CAPACITY


f Pmax =F f [ 0.85 fc' (Ag - Ast) + fy Ast] = 796.34 kips., (at max axial load, ACI 318-19 22.4)
where f = 0.65 , (ACI 318-19 Fig. R21.2.2b) > Pu [Satisfactory]
F = 0.8 , (ACI 318-19 Tab. 22.4.2.1) Ag = 314 in2 Ast = 3.52 in2

f Mn = 172 ft-kips @ Pu = 300 kips > Mu = 140 ft-kips [Satisfactory]


rmax = 0.06 (ACI 318-19 18.7.4.1) rprovd = 0.011
rmin = 0.01 (ACI 318-19 18.7.4.1& 10.6.1.1) [Satisfactory]

CHECK SHEAR CAPACITY (ACI 318-19 10 & 22.5)


f Vn = f (Vs + Vc) (ACI 318-19 22.5)
> Vu [Satisfactory]
where f = 0.75 (ACI 318-19 21.2) fy = 60 ksi
d A0 Av Vc = 2 (fc') A0
0.5
Vs = MIN (d fy Av / s , 4Vc) f Vn
x 17.6 182.7 0.40 25.8 35.3 46

smax = 12 (ACI 318-19 25.7) sprovd = 12 in


smin = 1 [Satisfactory]
PROJECT :
CLIENT :
JOB NO. : DATE :
Magnified Moment Calculation for Circular Column Based on ACI 318-19

INPUT DATA & DESIGN SUMMARY


EFFECTIVE LENGTH FACTOR k =
COLUMN UNSUPPORTED LENGTH Lu =
LARGER FACTORED MOMENT M2 =
SMALLER FACTORED END MOMENT M1 =
CONCRETE STRENGTH fc ' =
COLUMN DIAMETER D =
FACTORED AXIAL LOAD Pu =
SUMMATION FOR ALL VERTICAL LOADS IN THE STORY S Pu =
SUMMATION FOR ALL CRITICAL LOADS IN THE STORY S Pc =

THE MAGNIFIED MOMENT: Mu = 200.0 ft-k

ANALYSIS
MAGNIFIED MOMENT - NONSWAY
r = 0.25 D = 5.0 in, ACI 6.2.5.1
k Lu / r = 28.8 < 34 - 12(M1 / M2) = 33.28 < = = Slenderness effect may be ignored. (ACI 6.2.5
Ec = 57000 (fc') 0.5
= 3605.0 ksi, ACI 19.2.2
Ig = p D / 64 =
4
7854 in4

0.4 E c I g 0.4 E c I g
EI    0.25 E c I g  7078394 k-in2 , ACI 6.6.4.4.4
1 b d 1  0.6

p 2EI 
Pc  3369.07 k-in2 , ACI 6.6.4.4.4
 k Lu 
2

M2,min = MAX[ M2 , Pu (0.6+0.03 D) ] = 200 ft-k, ACI 6.6.4


Cm = MAX[ 0.6 + 0.4 (M1 / M2, min) , 0.4 ] = 0.624 , ACI 6.6.4.5

 
 
Cm
d ns  MAX  , 1.0  
1.00 , ACI 6.6.4.5.2
 1  Pu 
 0.75 P 
 c 

Mu, ns = dns M2, min = 200.0 ft-k, ACI 6.6.4.5.1 < 1.05 M2 = 210.0
The column is nonsway. Ign
MAGNIFIED MOMENT - SWAY < = = Not apply
k Lu / r = 28.8 > 22 < = = Slenderness effect must be considered. (ACI 6.2.5)
   
   
1
d s  MIN  MAX  , 1.0  , 2.5 
  1  S Pu   1.13 , ACI 6.6.4
  0.75S Pc  
   

Ag = p D2 / 4 = 314 in2
Lu / r = 28.80 < 35 / [Pu / (fc' Ag)]0.5 = 62.04 [Satisfactory]
M2s = M2 = 200.0 ft-k, as given
M2ns = 5% M2s = 10.0 ft-k, assumed conservatively
Mu, s = M2ns + ds M2s = 236.7 ft-k, ACI 6.6.4.6
PAGE :
DESIGN BY :
REVIEW BY :
318-19

1 , (ACI 6.2.5)
12 ft
200 ft-k
12 ft-k, (positive if single curvature.)
4 ksi
20 in
400 k
1200 k
13600 k, (ACI 6.6.4)

, Nonsway

may be ignored. (ACI 6.2.5)

ft-k [Satisfactory] ,(ACI 6.6.4.3)


olumn is nonsway. Ignore following calculations.
d. (ACI 6.2.5)

You might also like