0% found this document useful (0 votes)
406 views3 pages

Catalog Recuperator de Caldura Teknogen Tevhr

This document provides a technical specification for a TEVHR heat recovery ventilator. It can operate from 1-230V 50Hz or 3-380V 50Hz. It has an operating temperature range of -12°C to 46°C. Air flow rates range from 865 to 6500 cubic meters per hour with sound levels from 44 to 57 dB(A). Fan motor power is 215 to 1800W. Dimensions and duct connections vary by model size.

Uploaded by

Richard Brady
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
406 views3 pages

Catalog Recuperator de Caldura Teknogen Tevhr

This document provides a technical specification for a TEVHR heat recovery ventilator. It can operate from 1-230V 50Hz or 3-380V 50Hz. It has an operating temperature range of -12°C to 46°C. Air flow rates range from 865 to 6500 cubic meters per hour with sound levels from 44 to 57 dB(A). Fan motor power is 215 to 1800W. Dimensions and duct connections vary by model size.

Uploaded by

Richard Brady
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 3

Technical Specification

TEVHR
800 1000 1500 2000 2500 3000 4000 5000 6500
Power Supply 1~230 V 50 Hz 3~380 V 50 Hz
Working Range - 12°C ~ 46°C
Performance Data
Air Flow Rate (1) m3/h 865 1112 1500 2000 2500 3000 4000 5000 6500
Sound Level (2) dB (A) 44 45 46 48 49 50 52 53 57
Electrical Data
Fan Motor Power W 215 330 445 650 1150 800 1050 1430 1800
Max. Current (A) 1,0 1,45 2,0 3,0 4,8 4,0 5,1 6,4 3,6
General Data
Duct Connection
mm 200 x 200 200 x 200 170 x 270 250 x 300 300 x 300 370 x 370 370 x 370 430 x 430 430 x 430
Dimensions
1 It is measured when external static pressure is 0 Pa.
2 Sound level data are measured at 250 Hz and 1.5 m away from the unit’s bottom.

5
Components

Heat Recovery Recuperator EA SA


Exhaust Air Supply Air
• Long-lasting recuperator
with aluminum plates
• High heat transfer efficiency
• Low pressure drop
• Eurovent certificate
• Easy detachment and
maintenance via service cover OA RA
• Washability Outdoor Air Return Air

Plug Fan

• Backward blades with high aerodynamic efficiency


• Flexible connection with monophase structure
• Low power consumption
• Low sound level
• Protection against overheating
• Easy detachment and maintenance with service door and quick connector
• Compatibility with international quality and performance standards

Filters

• G4 class according to EN 779


• Cleanable
• Leakproof slide design

Unit Casing

• Steel casing with their corrosion resistance enhanced by RAL 9002


• Easy access to all components with service doors
• Easy service
• Nonflammable sound and thermal isolation
• Simplified assembly

Speed adjustment key

• Airflow rate control of supply and exhaust fans


• Minimum flow rate setting
• On/off function
• Compact design
• Operation indicator light

6
Dimensions

Model Dimensions
D L C A B Weight
mm kg
800 778 1232 361 200 200 51
1000 778 1232 361 200 200 52
1500 910 1425 370 270 170 72
2000 910 1425 435 300 250 84

TEVHR
2500 1171 1785 435 300 300 103
3000 1171 1785 525 370 370 116
4000 1171 1885 525 370 370 125
5000 1338 1985 652 430 430 186
6500 1338 1985 652 430 430 205

Duct Connection Configuration


Alternative Alternative
Air Outlet Air Outlet

RIGHT HAND SIDE


INSTALLATION
Air Outlet Air Outlet
(Exhaust Air or Fresh Air) (Exhaust Air or Fresh Air)

Air Inlet Air Inlet


(Return Air or Outside Air) (Return Air or Outside Air)

LEFT HAND SIDE


INSTALLATION
Air Outlet Air Inlet
(Exhaust Air or Fresh Air) (Return Air or Outside Air)

Air Inlet Air Outlet


(Return Air or Outside Air) (Exhaust Air or Fresh Air)

Alternate Alternate
Air Outlet Air Outlet

You might also like