0% found this document useful (0 votes)
46 views

Sa Lien T Features: Seriescs 310 0

The document describes flow computing units that measure corrected flow by taking temperature and pressure into account. It summarizes: 1) The Series μCS 3000 flow integrators and computing units measure corrected flow using inputs from differential pressure, temperature, and gauge pressure transmitters. 2) The units use a formula to calculate corrected flow based on uncorrected flow, differential pressure, pressure, and temperature. 3) Flameproof versions of the flow integrators are also described.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
46 views

Sa Lien T Features: Seriescs 310 0

The document describes flow computing units that measure corrected flow by taking temperature and pressure into account. It summarizes: 1) The Series μCS 3000 flow integrators and computing units measure corrected flow using inputs from differential pressure, temperature, and gauge pressure transmitters. 2) The units use a formula to calculate corrected flow based on uncorrected flow, differential pressure, pressure, and temperature. 3) Flameproof versions of the flow integrators are also described.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

Series µCS

Flow Integrators Totalizers Series CS 3000


3000

Flow C om puting U nits SSerie


eriess µ
µCCSS 310
31000

SA LIENT FEATURE S
6P rogram m able M icrocontroller B ased U nit
6E ight / S ix digit counter w ith non-volatile m em ory
6Independent display for flow rate indication
6P rogram m able A larm (on flow rate) and B atching Facility
6S erial C om m unication P ort w ith M O D B U S RTU P rotocol
6Isolated 4 to 20 m A retransm ission output
6B uilt-in tw o-w ire transm itter supply
6Various C utouts and sizes
6S ingle C hip design for ruggedness and low cost
6B uilt-in TE M P E R ATU R E P R E S S U R E C O M P E N S ATIO N (optional)

Th e µC S 300 0 serie s F low Integra tor Tota lizers a re pre cision instru me nts used along w ith flow m ete rs,
flow tran sm itters to indicate th e instan tan eous flo w rate and carry out the tota lization of flow.
Tw o set-points a re pro vided w hich can be configured on flow rate or on batches a nd hence can be u sed
as batch controllers.

TECHN ICAL SPECIFICATIONS

Input : 1) 4 to 2 0 m A D C , 0 to 20 m A D C (In put Im p edance < 200 ohm )


2) 1 to 5 V D C , 0 to 5 V D C (In put Im p edance > 2K ohm )
3) F requency 0 to 1 / 10 K H z (option al)
Input Typ e : Linear / square root p rogram m a ble
R ang e : C alibrated as pe r custo m e rs require m e nt fro m fro nt key p ad
D isplay : 1) 4 digit, ½ ” re d L ED for F low R ate indicatio n
: 2) 6 / 8 dig it, 0.3 ” red LE D for Tota lized Flow (resettable)
M em ory B ack-up : N on-vola tile m em ory (EE P R O M) storage uptill 1 0 yea rs
S et P oin ts : 2 no s program m able o ve r flow rate or batching
O u tpu t R ela ys : 1 N O + 1 N C per se t-point / ba tch, rated at 2 30 V A C , 5 A resistive load
Transm itter S upply : 2 4 V D C , 30 m A
R etransm ission O u tput : 4 to 20 m A (Isolated) optional
P rogram m ing : A ll param eters program m ab le by splash pro of front key pad
A ccuracy : < +/- 0.2% of FS D
S upply : 23 0 V A C , 50 H z (o the rs on request)
M ounting : Flush o n pa nel
D im ensions : C utout B ezel
1) 92 m m X 92m m 1) 96m m X 96m m
2) 13 8m m (H ) X 68m m (W ) 2) 1 44m m (H ) X 7 2m m (W )
3) 92 m m (W ) X 45m m (H ) 3) 9 6m m (W ) X 4 8m m (H )
D epth : Less tha n 2 00m m
O p erating Tem p eratu re : 0 to 65 deg C
Tem perature C oefficient : 0.015% / deg C
H um idity : 90% m axim um (non -co ndensing)

Fo r Flow Com puting Unit havin g bu ilt-in Tem perature Pressure Com pensation , the re w ill be tw o
add itional in puts, one from pressure transm itter and other from tem pe ra ture sensor in addition to th e input
fro m Flow Tra nsm itter. A ll oth er specificatio ns w ill be as ab ove.
Series µCS
Flow Integrators Totalizers Series CS 3000
3000

Flow C om puting U nits SSerie


eriess µ
µCCSS 33100
100

Flow C om puting U nit is used for m easu ring co rre cted flow of ste am / ga ses. It is w ell kn ow n tha t th e flow of a ny ga s
varies substa ntially w ith the chang e in tem perature or p re ssu re . A s a result no rm al flow m easuring techniq ues d o n ot
give the proper flow m easu re m e nt. To obtain the proper / correcte d flow, o ne h as to take into conside ra tio n the change s
in tem perature a nd pressu re. It is spe cifically for this ap plication that ou r Flow C om puting U nit h as be en designe d.

The Flow Com puting Unit w ill accept three inputs :

1) F ro m D ifferential P ressure Transm itter (or a ny flow m eter) correspo nding to uncorrected flow
2) F ro m G au ge Pre ssure Transm itter corresponding to actual pressure
3) F ro m Tem perature S en sor or Tem perature Tran sm itter

Th e F low C om puting U nit utilizes the follow ing form ula fo r correction :
Q = Q ` X S q.rt.(D P * P /T )
W h ere,
Q = C o rre cted Flow
Q` = U n co rre cted Flow
D P = Input from D P Transm itter (4 to 20 m A D C )
P = Input from P ressure Tra nsm itter (4 to 2 0 m A D C )
T = Input from RTD , Th/C se nsor or Transm iiter (4 to 20 m A D C )

Flow I nteg rator Total ize r


FLAM EP RO O F FLO W INDICATING TO TALIZERS
S eries µC S 30 00-E X

Th e µC S 3000 -EX is suita ble for field m ounting in haza rd ous a re as an d


can be fu lly p rogram m e d w ith out ope ning the enclosure.
Th e d ouble com partm ent enclosure h aving separate co m p artm ent for
term inals is e asy for m oun ting a nd m ainte nance.

M ounting : F ield, w all


E nclosure : C ast A lum in ium
P rote ctio n : F lam eproof G r IIA, IIB (IIC on request),
w e ath erproof IP 65
D im ensions : 350 m m (H ) X 188m m (W ) X 120m m (D )
P rogram m ing : F ro m fro nt w ithout opening enclosure

FLO W INDICATO R TO TALIZERS (NO N-PR O GR AMM ABLE)


S eries 3300 (ele ctrom echanical co unter type)
S eries 3400 (dig ita l cou nte r type)