(1) This radiographic report summarizes the inspection of two welded carbon steel plates using non-destructive testing techniques. (2) The plates had thicknesses of 25mm and 12mm and weld thicknesses of 28mm and 15mm, with single V edge preparations. (3) The reports provide details on inspection parameters, film quality assessments, and notes any defects observed.

Uploaded by

mangalraj900
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as RTF, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
257 views5 pages

Set 1

(1) This radiographic report summarizes the inspection of two welded carbon steel plates using non-destructive testing techniques. (2) The plates had thicknesses of 25mm and 12mm and weld thicknesses of 28mm and 15mm, with single V edge preparations. (3) The reports provide details on inspection parameters, film quality assessments, and notes any defects observed.

Uploaded by

mangalraj900
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as RTF, PDF, TXT or read online on Scribd
You are on page 1/ 5

Set 1 A

RADIOGRAPHIC INTERPRETATION – REPORT

Radiographic Identification: - PLS 13 G 3

Inspector: -

Date: - Course: NDT 2B

Material: Carbon Steel Plate Thickness: 25 mm

Weld Thickness: 28 mm

Welding Process: MMA Edge Preparation: Single V

KV/ Source: 160Kv Screens: Pb

Film Type: D7 (AGFA) FFD/SFD: _____________

Type of IQI used: Technique:_____________

Number of wire visible:

Film Density: a) Weld Zone _______________________________________


b) Parent Plate _______________________________________

________________________________________________________________________

Report

1. Calculate the sensitivity level for this radiograph?

2. Calculate the geometric unsharpness (Ug) based on the parameters given?

Not Required
2. Comments on Radiographic Quality

a. Sensitivity: ________________ b. Density: ________________


c. Technique: __________________________________________________

RADIOGRPHIC REPORT

3. SINGLE WALL SINGLE IMAGE (SWSI)

Note: - 1. Scratch mark noted on weld


2. Datum is taken from the edge of the film
Set 1 B

RADIOGRAPHIC INTERPRETATION – REPORT

Radiographic Identification: - S30

Inspector: -

Date: - ______________ Course: NDT 2B

Material: Carbon Steel Plate Thickness: 12 mm

Weld Thickness: 15 mm

Welding Process: MMA Edge Preparation: Single V

KV/ Source: Ir 192 / (1.5mm x 1.5mm) Screens: Pb

Film Type: D7 (AGFA) FFD/SFD: 300 mm

Type of IQI used: _______________________ Technique: SWSI

Number of wire visible: ____________________________________________________

Film Density: a) Weld Zone _______________________________________


b) Parent Plate _______________________________________

________________________________________________________________________

Report
4. Calculate the sensitivity level for this radiograph?
5. Calculate the geometric unsharpness (Ug) based on the parameters given?

3.Comments on Radiographic Quality

a. Sensitivity: _________ b. Density: _________ c. Technique: __________

RADIOGRPHIC REPORT

SINGLE WALL SINGLE IMAGE (SWSI)


Note: - 1. Datum is taken from the edge of the radiograph

You might also like