100% found this document useful (2 votes)
3K views1 page

Horizontal Life Line Calculation

This document summarizes the specifications for a horizontal lifeline system with a single 40 meter span. It lists details of the 3/8 inch cable such as its weight, breaking strength, and construction. It also provides calculations for the initial and maximum tensions on the cable, maximum deflection, and horizontal and vertical reactions at the anchorage points. The maximum arresting force is specified as 10 kN.

Uploaded by

hasan_676489616
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
100% found this document useful (2 votes)
3K views1 page

Horizontal Life Line Calculation

This document summarizes the specifications for a horizontal lifeline system with a single 40 meter span. It lists details of the 3/8 inch cable such as its weight, breaking strength, and construction. It also provides calculations for the initial and maximum tensions on the cable, maximum deflection, and horizontal and vertical reactions at the anchorage points. The maximum arresting force is specified as 10 kN.

Uploaded by

hasan_676489616
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

Horizontal lifeline system (HLLS) - 1 span

Project:
Engineer's name:
Firm:
Validated by:
Date: 11 May 2017

Cable Anchorage
Cable Diameter 3/8 in (9.5 mm) Anchorage Type Rigid
Cable Weight w (N/m) 3.65 Post Length LA (m) -
Frupt (kN) 49 Mr (kN.m) -
E (Gpa) 64.8 Mfmax (kN.m) -
A (mm²) 41.9 Material -
Cable FS 1.5 Ea (Gpa) 0
Construction IWRC 7x19 IA (106.mm4) 0

Mƒmax=αA x LA x Rx avec αA = 1.5 (CAN/CSA Z259.16)


Mr calculated according to CSA S16-09 or CAN3-S157

HLL System

Span length L 40 m

Initial deflection ƒ1 0.01 m

Initial tension T1 73000 N

Maximum arresting force F 10 kN

Maximum tension T 32.57 kN

Maximum deflection ƒ2 3.09 m

Horizontal reaction Rx 32.19 kN

Vertical reaction Ry 5.05 kN

With:

L = 40 m

ƒ1 = 0.01 m Post

LA
Sa
ƒ2 = 3.09 m T = 32.57 kN

Rx = 32.19 kN

Ry = 5.05 kN

F = 10 kN

IRSST - 2016