The Woodbridge LED post-top luminaire integrates LED technology with a proven post-top design. It has a die-cast aluminum housing and spun aluminum top that is completely removable without tools. It comes in grey or custom colors. It uses LEDs with a minimum 70 CRI and 4000K CCT standard. It has dimming and photocontrol options. It mounts to a 3" diameter tenon and is IP66 rated.

Uploaded by

Bob York
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
100% found this document useful (1 vote)
196 views2 pages

Eaton Strworks MPW Woodbridge Led Spec

The Woodbridge LED post-top luminaire integrates LED technology with a proven post-top design. It has a die-cast aluminum housing and spun aluminum top that is completely removable without tools. It comes in grey or custom colors. It uses LEDs with a minimum 70 CRI and 4000K CCT standard. It has dimming and photocontrol options. It mounts to a 3" diameter tenon and is IP66 rated.

Uploaded by

Bob York
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

D ES C R IPTION

Streetworks
The Woodbridge LED integrates energy saving LED technology with a Type
Catalog #
proven post-top design.

Project

Date
Comments

Prepared by

SPE C IFIC A TION FEA T U R E S

C on s t r u c t i o n El e c tri c a l Co n tro ls
Die-cast aluminum housing with 120-277V 50/60Hz operation 0-10V dimming driver standard.
spun and stamped aluminum top. standard. 480V and 347V available Photocontrol and After Hours Dim
Overcenter latch for relamping as options. 10kV /10kA common options available. Refer to control
and power module access. Top and differential mode surge options section.
is completely removable without protection standard. Thermal
the use of tools. Standard color management transfers heat Mo u n ting
is grey. Other finish colors rapidly away from the LED Post top mount fits 3” O.D. tenons.
available; consult your Streetworks source for optimal efficiency and Secured by square head 3/8”
representative. ANSI wattage/ light output. Ambient operating stainless steel mounting bolts.
source label. temperature from -40°C to 40°C.
Standard three-position tunnel type Warran ty
Optical compression terminal block. 95% Five-year warranty.
Injection molded acrylic refractor lumen maintenance expected at
available in symmetric or 60,000 hours. Light square is IP66 MPW
asymmetric distributions. Offered enclosure rated.
standard in 4000K (+/- 275K) CCT WOODBRIDGE
and minimum 70 CRI. LED
LED

D IMENS IONS DECORATIVE POST TOP


LUMINAIRE

21-1/2"
[546mm]

22-1/4" [565mm]

EPA
Effective Projected Area:
1.7 Square Feet

SHIPPING DATA
Approximate Net Weight:
34 lbs. (14 kgs.)

TEM
YS
S
S

TD516016EN
ER
D

February 20, 2019 1:26 PM


C

TIFIE
M P W W O O D B R I G E L ED

CONTRO L OPTIONS

Photocontrol (4, 4N7 or 4N7E)


Optional photocontrol receptacles provide a flexible solution to enable "dusk-to-dawn" lighting by sensing light levels. Advanced control systems
compatible with NEMA 7-PIN standards can be utilized with the 4N7 receptacle.

After Hours Dim (AHD)


This feature allows photocontrol-enabled luminaires to achieve additional energy savings by dimming during scheduled portions of the night. The
dimming profile will automatically take effect after a "dusk-to-dawn" period has been calculated from the photocontrol input. Specify the desired
dimming profile for a simple, factory-shipped dimming solution requiring no external control wiring. Reference the After Hours Dim supplemental
guide for additional information.

POWER A ND LUM ENS L UME N MA INT E NA NCE

Drive Current 600mA 800mA 1A TM-21 Projected


Ambient
Lumen Maintenance L70
Temperature
Nominal Power @ 120-277V (Watts) 34 44 58 (60,000 Hours) (Hours)

Input Current @ 120V (Amps) 0.3 0.39 0.51 Up to 40°C >95% 416,000

Input Current @ 208V (Amps) 0.17 0.22 0.29

Input Current @ 240V (Amps) 0.15 0.19 0.26

Input Current @ 277V (Amps) 0.14 0.17 0.23

Input Current @ 347V (Amps) 0.11 0.15 0.17

Input Current @ 480V (Amps) 0.08 0.11 0.14

Distribution

4000K, 5000K, 6000K


3,025 3,709 4,591
Lumens

BUG Rating B1-U3-G2 B1-U3-G2 B2-U3-G2


SYM
3000K Lumens 2,859 3,507 4,341

BUG Rating B1-U3-G2 B1-U3-G2 B1-U3-G2

4000K, 5000K, 6000K


2,848 3,493 4,323
Lumens

BUG Rating B1-U3-G2 B1-U3-G2 B1-U3-G2


ASYM
3000K Lumens 2,693 3,303 4,087

BUG Rating B1-U3-G2 B1-U3-G2 B1-U3-G2

OR D ER ING INFOR M A TION


Sample Number: MPW-AF-D-U-SYM-4-AP

Product Family 1 Light Engine Driver Voltage Distribution Options (Add as Needed) Color Accessories (Order Separately)

MPW=Woodbridge AF=1A Drive D=Dimming U=Universal SYM=Symmetric 7027=70 CRI / 2700K 2 AP=Grey OA1223=10kV/10kA UL 1449
Current (120-277V) ASYM=Asymmetric 7030=70 CRI / 3000K 2 BK=Black Surge Module
8= 4 80V 7050=70 CRI / 5000K 2 BZ=Bronze Replacement
9=3 47V 7060=70 CRI / 6000K 2 WH=W hite OA/RA1013=Photocontrol
8030=80 CRI / 3000K 2 Shorting Cap
600=D rive Current Factory Set to OA/RA1014=NEMA
600mA (nominal) Photocontrol -
800=D rive Current Factory Set to 120V
800mA (nominal) OA/RA1016=NEMA
4=N EMA Photocontrol Receptacle Photocontrol -
4N7=N EMA 7-PIN Multi-Tap
Photocontrol Receptacle OA/RA1027=NEMA
(Internal Mount) 3 Photocontrol -
4N7E=N EMA 7-PIN 480V
Photocontrol Receptacle OA/RA1201=NEMA
(External Top Mount) Photocontrol -
AHD145=After Hours Dim, 5 Hours 4 347V
AHD245=After Hours Dim, 6 Hours 4
AHD255=After Hours Dim, 7 Hours 4
AHD355=After Hours Dim, 8 Hours 4

NOTES:
1. Customer is responsible for engineering analysis to confirm pole and fixture compatibility for all applications. Refer to our white paper WP513001EN for additional support information.
2. Use dedicated IES files for various CCTs and CRIs when performing layouts. These files are published on the Woodbridge LED luminaire product page on the website. Extended lead times apply.
3. Total height of photocontrol/node cannot exceed 4-9/32”.
4. Requires the use of Photocontrol (4, 4N7, or 4N7E) receptacle. See After Hours Dim supplemental guide for additional information.

Eaton
1121 Highway 74 South
Peachtree City, GA 30269 Specifications and
P: 770-486-4800 dimensions subject to TD516016EN
www.eaton.com/lighting change without notice. February 20, 2019 1:26 PM

You might also like