0% found this document useful (0 votes)
286 views4 pages

Leg Support

The document provides results from structural analysis of vessel legs in two load cases: operating and hydrotest (filled with water). It analyzes properties of square tubing legs, load calculations, stress levels, and checks that stresses are below allowable values. Anchor bolt sizing requirements are also provided for attaching the legs to baseplates.

Uploaded by

MukeshChopra
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as DOC, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
286 views4 pages

Leg Support

The document provides results from structural analysis of vessel legs in two load cases: operating and hydrotest (filled with water). It analyzes properties of square tubing legs, load calculations, stress levels, and checks that stresses are below allowable values. Anchor bolt sizing requirements are also provided for attaching the legs to baseplates.

Uploaded by

MukeshChopra
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as DOC, PDF, TXT or read online on Scribd
You are on page 1/ 4

PV Elite 2019 SP2 Licensee 1

FileName : Seal Pot --------------------------------------


Leg Check, (Operating Case): Step: 17 9:45am Jan 15,2020

RESULTS FOR LEGS : Operating Case Description: LEGS

Legs attached to: Shell

Section Properties : Sq/Rect Tubing BT50X50X6.3

European Structural Steel Data

Overall Leg Length 870.000 mm


Effective Leg Length Leglen 870.000 mm
Distance Leg Up Side of Vessel 0.000 mm
Number of Legs Nleg 2
Cross Sectional Area for BT50X50X6.3 Aleg 1101.238 mm²
Section Inertia ( strong axis ) 357787.219 mm**4
Section Inertia ( weak axis ) 357787.219 mm**4
Section Modulus ( strong axis ) 14311.658 mm ³
Section Modulus ( weak axis ) 14311.658 mm ³
Radius of Gyration ( strong axis ) 18.025 mm
Radius of Gyration ( weak axis ) 18.025 mm

Leg Orientation - Weak Axis

Overturning Moment at top of Legs 61.4 N-m


Total Weight Load at top of Legs W 680.7 N
Total Shear force at top of Legs 217.7 N
Additional force in Leg due to Bracing Fadd 0.0 N
Occasional Load Factor Occfac 1.333
Effective Leg End Condition Factor k 1.000

Note: The Legs are Not Cross Braced


The Leg Shear Force includes Wind and Seismic Effects

Maximum Shear at top of one Leg [Vleg]:


= ( max( Wind, Seismic ) + applied forces )( Imax / Itot )
= ( 217.7 )( 357791/715582 )
= 108.84 N

Axial Compression, Leg furthest from the Neutral Axis [Sma]:


= W/Nleg + (Mleg/(Nlegm*Rn))/Aleg
= 680.8/2 + (61412/( 1 * 109.1 ))/1101
= 8.36 kgf/cm²

Axial Compression, Leg closest to the Neutral Axis [Sva]:


= ( W / Nleg ) / Aleg
= ( 680.7/2 )/1101
= 3.15 kgf/cm²

Allowable Comp. for the Selected Leg (KL/r < Cc ) [Sa]:


= Occfac * ( 1-(kl/r)²/(2*Cc²))*Fy /
( 5/3+3*(Kl/r)/(8*Cc)-(Kl/r³)/(8*Cc³)
= 1.333 * ( 1-( 48.27 )²/(2 * 127.2² )) * 2531/
( 5/3+3*( 48.27 )/(8* 127.2 )-( 48.27³)/(8* 127.2³)
= 1737.33 kgf/cm²

Bending at the Bottom of the Leg closest to the N.A. [S]:


= ( Vleg * Leglen / Smdwa )
= ( 108.8 * 870/14312 )
= 67.47 kgf/cm²

Allowable Bending Stress[Sb]:


= ( 0.6 * Fy * Occfac )
= ( 0.6 * 2531 * 1.333 )
= 2024.33 kgf/cm²
PV Elite 2019 SP2 Licensee 2
FileName : Seal Pot --------------------------------------
Leg Check, (Operating Case): Step: 17 9:45am Jan 15,2020

AISC Unity Check [Sc]( must be < or = to 1.00 ) :


= (Sma/Sa)+(0.85*S)/((1-Sma/Spex)*Sb)
= (8.362/1737 )+( 0.85 *67.47 )/(( 1 -8.362/6111 ) *2024 )
= 0.0332

Bolting Size Requirement for Leg Baseplates :

Baseplate Material SA-240 304


Baseplate Allowable Stress SBA 1407.13 kgf/cm²
Baseplate Length B 120.0000 mm
Baseplate Width D 120.0000 mm
Baseplate Thickness BTHK 10.0000 mm
Leg Dimension Along Baseplate Length d 0.0000 mm
Leg Dimension Along Baseplate Width b 0.0000 mm
Dist. from the Leg Edge to Bolt Hole Center z 15.0000 mm
Bolt Material SA-193 B7
Bolt Allowable Tensile Stress STBA 1753.82 kgf/cm²
Bolt Allowable Shear Stress SBShear 800.00 kgf/cm²
Anchor Bolt Nominal Diameter BOD 12.0000 mm
Number of Anchor Bolts in Tension per Leg NB 2
Total Number of Anchors Bolt per Leg NBT 4
Ultimate 28-day Concrete Strength FCPRIME 210.921 kgf/cm²

Baseplate analysis is performed for Angle, Beam & Pipe legs only.

PV Elite is a trademark of Intergraph CADWorx & Analysis Solutions, Inc. 2019


PV Elite 2019 SP2 Licensee: THE CULMINATES ENGG. SERVICES 3
FileName : Seal Pot --------------------------------------
Leg Check, (Filled w/Water): Step: 18 9:45am Jan 15,2020

RESULTS FOR LEGS : HydroTest Case Description: LEGS

Legs attached to: Shell

Section Properties : Sq/Rect Tubing BT50X50X6.3

European Structural Steel Data

Overall Leg Length 870.000 mm


Effective Leg Length Leglen 870.000 mm
Distance Leg Up Side of Vessel 0.000 mm
Number of Legs Nleg 2
Cross Sectional Area for BT50X50X6.3 Aleg 1101.238 mm²
Section Inertia ( strong axis ) 357787.219 mm**4
Section Inertia ( weak axis ) 357787.219 mm**4
Section Modulus ( strong axis ) 14311.658 mm ³
Section Modulus ( weak axis ) 14311.658 mm ³
Radius of Gyration ( strong axis ) 18.025 mm
Radius of Gyration ( weak axis ) 18.025 mm

Leg Orientation - Weak Axis

Overturning Moment at top of Legs 30.7 N-m


Total Weight Load at top of Legs W 579.2 N
Total Shear force at top of Legs 91.3 N
Additional force in Leg due to Bracing Fadd 0.0 N
Occasional Load Factor Occfac 1.333
Effective Leg End Condition Factor k 1.000

Note: The Legs are Not Cross Braced


The Leg Shear Force includes Wind and Seismic Effects

Maximum Shear at top of one Leg [Vleg]:


= ( max( Wind, Seismic ) + applied forces )( Imax / Itot )
= ( 91.27 )( 357791/715582 )
= 45.63 N

Axial Compression, Leg furthest from the Neutral Axis [Sma]:


= W/Nleg + (Mleg/(Nlegm*Rn))/Aleg
= 579.2/2 + (30706/( 1 * 109.1 ))/1101
= 5.29 kgf/cm²

Axial Compression, Leg closest to the Neutral Axis [Sva]:


= ( W / Nleg ) / Aleg
= ( 579.2/2 )/1101
= 2.68 kgf/cm²

Allowable Comp. for the Selected Leg (KL/r < Cc ) [Sa]:


= Occfac * ( 1-(kl/r)²/(2*Cc²))*Fy /
( 5/3+3*(Kl/r)/(8*Cc)-(Kl/r³)/(8*Cc³)
= 1.333 * ( 1-( 48.27 )²/(2 * 127.2² )) * 2531/
( 5/3+3*( 48.27 )/(8* 127.2 )-( 48.27³)/(8* 127.2³)
= 1737.33 kgf/cm²

Bending at the Bottom of the Leg closest to the N.A. [S]:


= ( Vleg * Leglen / Smdwa )
= ( 45.63 * 870/14312 )
= 28.29 kgf/cm²

Allowable Bending Stress[Sb]:


= ( 0.6 * Fy * Occfac )
= ( 0.6 * 2531 * 1.333 )
= 2024.33 kgf/cm²
PV Elite 2019 SP2 Licensee: THE CULMINATES ENGG. SERVICES 4
FileName : Seal Pot --------------------------------------
Leg Check, (Filled w/Water): Step: 18 9:45am Jan 15,2020

AISC Unity Check [Sc]( must be < or = to 1.00 ) :


= (Sma/Sa)+(0.85*S)/((1-Sma/Spex)*Sb)
= (5.287/1737 )+( 0.85 *28.29 )/(( 1 -5.287/6111 ) *2024 )
= 0.0149

Bolting Size Requirement for Leg Baseplates :

Baseplate Material SA-240 304


Baseplate Allowable Stress SBA 1407.13 kgf/cm²
Baseplate Length B 120.0000 mm
Baseplate Width D 120.0000 mm
Baseplate Thickness BTHK 10.0000 mm
Leg Dimension Along Baseplate Length d 0.0000 mm
Leg Dimension Along Baseplate Width b 0.0000 mm
Dist. from the Leg Edge to Bolt Hole Center z 15.0000 mm
Bolt Material SA-193 B7
Bolt Allowable Tensile Stress STBA 1753.82 kgf/cm²
Bolt Allowable Shear Stress SBShear 800.00 kgf/cm²
Anchor Bolt Nominal Diameter BOD 12.0000 mm
Number of Anchor Bolts in Tension per Leg NB 2
Total Number of Anchors Bolt per Leg NBT 4
Ultimate 28-day Concrete Strength FCPRIME 210.921 kgf/cm²

Baseplate analysis is performed for Angle, Beam & Pipe legs only.

PV Elite is a trademark of Intergraph CADWorx & Analysis Solutions, Inc. 2019