Truncated Catalog Realeased 14-05-19 Final Compressed PDF
Truncated Catalog Realeased 14-05-19 Final Compressed PDF
SELECTION GUIDE
www.selec.com
Index
METERS 3
Multifunction Meters
Energy Meters
Digital Panel Meters (VAF Meter, Voltmeter, Ammeter, Frequency Meter)
Analog Meters
Current Transformers
Power Factor Controllers
Ordering Information
TIMERS 17
Analog Timers
Digital Timers
Time Interval Meter / Hour Meters
Ordering Information
Aluminium Enclosures 33
Panel Cutout Dimension 34
2 www.selec.com
Multifunction Meters
! Bar graph representation for current ! Compact size ! Single pulse output ! Single pulse output
! Single pulse output ! Single pulse output ! Energy (Active / Reactive / Apparent) ! Max / Min demand (Power)
FEATURES ! %THD up to 31st level ! %THD up to 31st level ! Run hour
! Demand measurement ! Demand measurement ! Auxiliary interrupts
! Phase angle detection
PT PRIMARY 100V to 500kV (Programmable for any value) 100V to 10kV (Programmable for any value) 100V to 500kV (Programmable for any value)
PT SECONDARY 100 to 500V AC (L - L) (Programmable for any value)
COMMUNICATION RS485 MODBUS RTU protocol (Optional)
MEASURING Voltage (L - L / L - N) (Individual / Average), Current (Individual / Average), Frequency, Power factor (Individual / Total), Active,
PARAMETER Reactive & Apparent Power (Individual / Total), Active, Reactive & Apparent Energy (Total)
Max instantaneous (Current / Voltage),
ADDITIONAL Phase sequence detection, Neutral current measurement --- (Import / Export) Energy,
FUNCTIONS %THD up to 31st level (For MFM376-C)
240V AC, ±20% (For MFM376-230VAC),
SUPPLY VOLTAGE 100 to 240V AC, -15% to +12%, 50 / 60Hz (Power consumption : Less than 8VA) 50 / 60Hz, 85V to 270V AC 50 / 60Hz &
40 to 270V DC, (For MFM376-C)
MFM384-R-C EM2M
90(H) x 70(W)mm 90(H) x 35(W)mm
Voltage (L - L / L - N), Current : ±0.5% of F.S., Voltage (L - N), Current: ±0.5% of F.S.
Power factor : ±0.01, Frequency : ±0.1% of F.S., Power factor: ±0.01, Frequency: ±0.1% of F.S.
ACCURACY CLASS Power (kW, kVA, kVAr) : 1% of F.S. Power (kW, kVA, kVAr): 1% of F.S.
Energy (Active, Reactive, Apparent) : 1% of F.S. Active energy: Class 1, Reactive energy: Class 2
SUPPLY VOLTAGE 85 to 270V AC, 50 / 60Hz 176 to 276V AC (L-N), Self powered
! Energy (Active, Reactive) ! Energy (Active, Reactive) ! Energy (Active, Reactive, Apparent)
! RJ45 connector current input ! RJ45 connector current input ! Split load, RJ45 connector current input
Single pulse output 2 pulse outputs
! Single pulse output
FEATURES ! !
! Demand measurement
! Max demand of power ! Max demand of power ! Self powered
! Self powered ! Self powered ! %THD up to 31st level
DISPLAY LCD with backlight
4 rows of 4 digits, Bar graph representation for current,
DIGITS 2 rows of 4 digits, 1 row of 7 digits to show electrical parameters
1 row of 8 digits for energy display
ELECTRICAL
1Ø - 2W, 3Ø - 4W
CONNECTION
RATED INPUT VOLTAGE 60 to 300V AC (L - N), 104 to 520V AC (L - L) 100 to 240V AC (L - N ), 173 to 415V AC (L - L)
RESOLUTION For Energy : 0.01K, 0.1K, 1K, 0.01M, 0.1M, 1M (Depending upon CT ratio x PT ratio), For Power, Voltage, Current : Auto resolution For Power factor : 0.01
CT SECONDARY 330mV
PT PRIMARY 100V to 10kV (Programmable for any value) 100V to 500kV (Programmable for any value)
PT SECONDARY 100 to 500V AC (L - L) (Programmable for any value) 173 to 415V AC (L - L) (Programmable for any value)
DESCRIPTION PWCT
CURRENT INPUT 60A, 100A, 125A, 150A, 160A, 200A, 250A, 300A, 400A, 500A, 600A, 630A, 800A, 1000A, 1250A, 1600A
PWCT
EM306A EM368
96(H) x 96(W)mm 96(H) x 96(W)mm
COMMUNICATION Rs485 MODBUS RTU protocol (For EM306A-C) RS485 MODBUS RTU protocol (For EM368-C)
VAF36A VAF39A-1
96(H) x 96(W)mm 96(H) x 96(W)mm
RATED INPUT CURRENT Nominal 5A (Min - 20mA ; Max - 6A) Nominal 5A (Min - 30mA ; Max - 6A)
RESOLUTION Current & Voltage: Depending on CT & PT primary setting, RPM : 0.1, Run hour : 0.1hr
ACCURACY Voltage(L - N / L - L / Average): ± 0.5% of F.S. ± 2 digits, Current & Average Current: ± 1% of F.S. ± 2 digits, Run hour: ± 1%, RPM: ± 0.5%, Frequency: ± 0.1 Hz ± 1 digit
SUPPLY VOLTAGE 240V AC ±20% (50 / 60Hz) 230V AC ±20% (50 / 60Hz)
Digital Ammeters
DIGITS 4 digits
ELECTRICAL 1Ø - 2W, 3Ø - 3W, 3Ø - 4W
1Ø - 2W
CONNECTION
INPUT TYPE CT Shunt Direct CT
RATED INPUT CURRENT 5A AC (Min - 50mA ; Max - 6.2A) 0 to 75mV DC 20A Direct 5A AC (Min - 50mA ; Max - 6.2A)
SUPPLY VOLTAGE 240V AC ±20% (50 / 60Hz) 230V AC ±20% (50 / 60Hz)
Part No.
! True RMS measurement ! True RMS measurement ! True RMS measurement ! True RMS measurement
! Bar graph representation for current ! Bar graph representation for current ! Bar graph representation for voltage ! Bar graph representation for voltage
! CT primary programmable up to ! CT primary programmable up to ! Selector switch for page selection
FEATURES
5000A 5000A
! Selector switch for page selection
ELECTRICAL
1Ø - 2W 3Ø - 4W 1Ø - 2W 3Ø - 3W, 3Ø - 4W
CONNECTION
RATED INPUT VOLTAGE --- 50 to 480V AC (Max: 516V)
Frequency Meters
Analog Meters
! True RMS (Voltage) ! True RMS (Current) ! True RMS (Current) ! Non linear scale ! Linear scale
measurement measurement measurement ! Easy installation / ! Easy installation /
FEATURES ! Scale inter changeability ! Scale inter changeability ! Non linear scale termination termination
! Non linear scale ! Non linear scale ! Easy installation /
! Easy installation / termination ! Easy installation / termination termination
! Use with different bus bar size ! Selable terminal / Wire type output ! Terminal output
FEATURES ! Panel mount / DIN rail mount (Require optional accessory) ! Panel mount ! Accuracy: Class 0.5 to 5
! Accuracy: Class 0.5 to 5 ! Accuracy: Class 1 to 5
RATED PRIMARY
30 to 4000A 30 to 600A 30 to 1600A
RATING
RATED SECONDARY
5A
OUTPUT
RATED BURDEN (VA) 1,1.25, 1.5, 2.5, 3, 3.75, 5, 7.5, 10, 15 1.5, 5 1.5, 5, 10
ACCURACY 0.5,1, 3, 5 1, 5 0.5, 1, 5
OPERATING AC 50 / 60Hz
FREQUENCY
SYSTEM VOLTAGE 720V max
APPLICABLE STANDARD IEC 61869-2 ---
RATED INPUT CURRENT Nominal 5A AC (Min - 11mA; Max - 6A) Nominal 5A AC (Min - 50mA; Max - 6A)
POWER CONSUMPTION 15VA max 7VA max
FREQUENCY 45 to 65Hz
MEASUREMENT RANGE Power factor : 0.8 lag to 0.8 lead
Over / Under Voltage, Over / Under Compensation, Over / Under Voltage, Over / Under Compensation,
ALARM SETTINGS CT polarity error, Over temperature, Fan setting, No voltage, THDI. CT Polarity Error, Current Absent Indication, No Volt
COMMUNICATION RS485 MODBUS RTU protocol *(Only for 12 stage variant) ---
MFM384-C-CE 100V to 240V AC, -15% to ±12% YES YES Plug-n-wire Multifunction Meter
MFM284-C-CE 85 to 270V AC YES YES OUTPUT
MFM383A 100V to 240V AC, -15% to ±12% YES PRODUCT CODE PULSE COMMN. CERTIFICATION
MFM383A-C-CE 100V to 240V AC, -15% to ±12% YES YES OUTPUT (RS485)
MFM376-230VAC 240V AC ± 20% YES MRJ4M YES YES
MFM376-C-CE 85 to 270V AC, 40 to 270V DC YES YES MRJ4M-SL YES YES
MRJ385-G-PNW YES YES
Energy Meters
Voltage Ampere Frequency Meters
SUPPLY OUTPUT
PRODUCT CODE CERTIFICATION
VOLTAGE PULSE OUTPUT COMMN. (RS485) PRODUCT CODE SUPPLY VOLTAGE CERTIFICATION
100 to 240V AC, UL US VAF36A-230-CE 230V AC
EM368-C-CU YES YES C
LED ( Ammeters )
LED ( Voltmeters )
PRODUCT CODE SUPPLY VOLTAGE CERTIFICATION
PRODUCT CODE SUPPLY VOLTAGE CERTIFICATION MA12 230V AC
MV15 230V AC MA12-CE 230V AC
MV15-CE 230V AC MA12-20A-AC 230V AC
MV205 230V AC MA12-75mV-DC 230V AC
MV205-CE 230V AC MA202 230V AC
MV305 230V AC MA202-CE 230V AC
MV305-CE 230V AC MA302 230V AC
MV334-230V 230V AC MA302-CE 230V AC
MV334-230V-CE 230V AC MA335-230VAC 230V AC
MA335-230VAC-CE 230V AC
LCD ( Ammeters / Voltmeters)
PRODUCT CODE SUPPLY VOLTAGE CERTIFICATION
MA501-230V-CE 230V AC
Power Factor Controllers
MA501-CU 230V AC C UL US
LISTED OUTPUT
MA2301-230V-CE 230V AC PRODUCT CODE SUPPLY VOLTAGE COMMN. CERTIFICATION
STEPS (RS485)
MV507-230V-CE 230V AC
MV2307-230V-CE 230V AC APFC148-312-90/550V 90 to 550V AC, 50 / 60Hz 12 YES ---
APFC147-108-90/550V 90 to 550V AC, 50 / 60Hz 8 --- ---
Frequency Meters APFC147-112-90/550V 90 to 550V AC, 50 / 60Hz 12 --- ---
PRODUCT CODE SUPPLY VOLTAGE CERTIFICATION APFC347-108-230V 85 to 270V AC, 50 / 60Hz 8 --- ---
MF16 240V AC --- APFC148-312-90/550V-CE 90 to 550V AC, 50 / 60Hz 12 YES
MF216 240V AC --- 90 to 550V AC, 50 / 60Hz ---
APFC147-108-90/550V-CE 8
MF316 240V AC --- 85 to 270V AC, 50 / 60Hz ---
APFC347-108-230V-CE 8
SPCT RCT
NO OF
WIRE APERTURE CURRENT BURDEN ACCURACY WIRE APERTURE CURRENT BURDEN ACCURACY
PRODUCT CODE PRODUCT CODE PRIMARY
In mm RATIO IN VA CLASS In mm RATIO IN VA CLASS TURNS
SPCT 50/30 60/5 A VA 1 CL 5 30x10 60 / 5 1 5 RCT-T-D30-30/5 A VA 1.5 CL5 DIA 30 30/5 1.5 5 ---
SPCT 50/30 75/5 A VA 1 CL 1 30x10 75 / 5 1 1 RCT-T-D30-30/5 A VA 5 (2T) CL5 DIA 30 30/5 5 5 2
SPCT 50/30 80/5 A VA 1 CL 1 30x10 80 / 5 1 1 RCT-T-D30-50/5 A VA 5 CL5 DIA 30 50/5 5 5 ---
SPCT 50/30 100/5 A VA 1 CL 1 30x10 100 / 5 1 1 RCT-T-D30-75/5 A VA 5 CL5 DIA 30 75/5 5 5 ---
SPCT 50/30 125/5 A VA 1.25 CL 1 30x10 125 / 5 1.25 1 RCT-T-D30-100/5 A VA 5 CL1 DIA 30 100/5 5 1 ---
SPCT 50/30 160/5 A VA 1.5 CL 1 30x10 160 / 5 1.5 1 RCT-T-D30-150/5 A VA 5 CL1 DIA 30 150/5 5 1 ---
SPCT 50/30 200/5 A VA 3 CL 1 30x10 200 / 5 3 1 RCT-T-D50-200/5 A VA 5 CL1 DIA 50 200/5 5 1 ---
SPCT 50/30 250/5 A VA 3 CL 1 30x10 250 / 5 3 1 RCT-T-D50-250/5 A VA 5 CL1 DIA 50 250/5 5 1 ---
SPCT 50/30 400/5 A VA 5 CL 1 30x10 400 / 5 5 1 RCT-T-D50-300/5 A VA 5 CL1 DIA 50 300/5 5 1 ---
SPCT 62/22 30/5 A VA 1 CL 5 DIA 22 30/5 1 5 RCT-T-D50-400/5 A VA 5 CL1 DIA 50 400/5 5 1 ---
SPCT 62/30 50/5 A VA 1 CL 3 30x10 50/5 1 3 RCT-T-D50-500/5 A VA 5 CL1 DIA 50 500/5 5 1 ---
SPCT 62/30 50/5 A VA 1.5 CL 3 30x10 50/5 1.5 3 RCT-T-D50-600/5 A VA 5 CL1 DIA 50 600/5 5 1 ---
SPCT 62/30 75/5 A VA 1 CL 3 30x10 75/5 1 3 RCT-W-D30-30/5 A VA 1.5 CL5 DIA 30 30/5 1.5 5 ---
SPCT 62/30 75/5 A VA 3 CL 3 30x10 75/5 3 3 RCT-W-D30-30/5 A VA 5 (2T) CL5 DIA 30 30/5 5 5 2
SPCT 62/30 100/5 A VA 1 CL 1 30x10 100/5 1 1 RCT-W-D30-50/5 A VA 5 CL5 DIA 30 50/5 5 5 ---
SPCT 62/30 100/5 A VA 3 CL 1 30x10 100/5 3 1 RCT-W-D30-75/5 A VA 5 CL5 DIA 30 75/5 5 5 ---
SPCT 62/40 100/5 A VA 1 CL 1 40x10 100/5 1 1 RCT-W-D30-100/5 A VA 5 CL1 DIA 30 100/5 5 1 ---
SPCT 62/40 125/5 A VA 1 CL 1 40x10 125/5 1 1 RCT-W-D30-150/5 A VA 5 CL1 DIA 30 150/5 5 1 ---
SPCT 62/40 150/5 A VA 1.5 CL 1 40x10 150/5 1.5 1 RCT-W-D50-200/5 A VA 5 CL1 DIA 50 200/5 5 1 ---
SPCT 62/40 150/5 A VA 3 CL 1 40x10 150/5 3 1 RCT-W-D50-250/5 A VA 5 CL1 DIA 50 250/5 5 1 ---
SPCT 62/40 160/5 A VA 1.5 CL 1 40x10 160/5 1.5 1 RCT-W-D50-300/5 A VA 5 CL1 DIA 50 300/5 5 1 ---
SPCT 62/40 200/5 A VA 2.5 CL 0.5 40x10 200/5 2.5 0.5 RCT-W-D50-400/5 A VA 5 CL1 DIA 50 400/5 5 1 ---
SPCT 62/40 200/5 A VA 3 CL 1 40x10 200/5 3 1 RCT-W-D50-500/5 A VA 5 CL1 DIA 50 500/5 5 1 ---
SPCT 62/40 250/5 A VA 2.5 CL 0.5 40x10 250/5 2.5 0.5 RCT-W-D50-600/5 A VA 5 CL1 DIA 50 600/5 5 1 ---
SPCT 62/40 250/5 A VA 3 CL 1 40x10 250/5 3 1
SPCT 62/40 300/5 A VA 3 CL 0.5 40x10 300/5 3 0.5
SPCT 62/40 400/5 A VA 3.75 CL 0.5 40x10 400/5 3.75 0.5 TWCT
SPCT 62/40 400/5 A VA 5 CL 1 40x10 400/5 5 1
WIRE APERTURE CURRENT BURDEN ACCURACY
SPCT 100/60 500/5 A VA 5 CL 1 60x12 500/5 5 1 PRODUCT CODE
In mm RATIO IN VA CLASS
SPCT 100/60 600/5 A VA 5 CL 0.5 60x12 600/5 5 0.5
TWCT-T-D35 30/5 A VA 1.5 CL 5 DIA 35 30/5 1.5 5
SPCT 100/60 600/5 A VA 7.5 CL 1 60x12 600/5 7.5 1
TWCT-T-D35 50/5 A VA 5 CL 5 DIA 35 50/5 5 5
SPCT 100/60 800/5 A VA 10 CL 0.5 60x12 800/5 10 0.5
TWCT-T-D35 75/5 A VA 5 CL 5 DIA 35 75/5 5 5
SPCT 100/60 1000/5 A VA 15 CL 0.5 60x12 1000/5 15 0.5
TWCT-T-D35 100/5 A VA 5 CL 1 DIA 35 100/5 5 1
SPCT 100/60 1200/5 A VA 15 CL 0.5 60x12 1200/5 15 0.5
TWCT-T-D35 150/5 A VA 5 CL 1 DIA 35 150/5 5 1
SPCT 140/100 800/5 A VA 15 CL 0.5 100x30 800/5 15 0.5
TWCT-T-D55 150/5 A VA 5 CL 1 DIA 55 150/5 5 1
SPCT 140/100 1000/5 A VA 15 CL 0.5 100x30 1000/5 15 0.5
TWCT-T-D55 200/5 A VA 5 CL 1 DIA 55 200/5 5 1
SPCT 140/100 1200/5 A VA 15 CL 0.5 100x30 1200/5 15 0.5
TWCT-T-D55 250/5 A VA 5 CL 1 DIA55 250/5 5 1
SPCT 140/100 1250/5 A VA 15 CL 0.5 100x30 1250/5 15 0.5
TWCT-T-D55 300/5 A VA 5 CL 1 DIA 55 300/5 5 1
SPCT 140/100 1500/5 A VA 15 CL 0.5 100x30 1500/5 15 0.5
SPCT 140/100 1600/5 A VA 15 CL 0.5 TWCT-T-D55 400/5 A VA 5 CL 1 DIA 55 400/5 5 1
100x30 1600/5 15 0.5
SPCT 140/100 2000/5 A VA 15 CL 0.5 100x30 TWCT-T-D65 500/5 A VA 5 CL 1 DIA 65 500/5 5 1
2000/5 15 0.5
SPCT 140/100 2500/5 A VA 15 CL 0.5 100x30 2500/5 15 0.5 TWCT-T-D65 600/5 A VA 5 CL 1 DIA 65 600/5 5 1
TWCT-T-D110 800/5 A VA 10 CL 0.5 DIA 110 800/5 10 0.5
SPCT 140/100 3000/5 A VA 15 CL 0.5 100x30 3000/5 15 0.5
SPCT 140/100 3500/5 A VA 15 CL 0.5 100x30 3500/5 15 0.5 TWCT-T-D110 1000/5 A VA 10 CL 0.5 DIA 110 1000/5 10 0.5
SPCT 140/100 4000/5 A VA 15 CL 0.5 100x30 4000/5 15 0.5 TWCT-T-D120 1000/5 A VA 10 CL 0.5 DIA 120 1000/5 10 0.5
TWCT-T-D120 1200/5 A VA 10 CL 0.5 DIA 120 1200/5 10 0.5
TWCT-T-D120 1600/5 A VA 10 CL 0.5 DIA 120 1600/5 10 0.5
! Monitor phase failure, ! Monitor phase failure, ! Monitor phase failure, ! Monitor phase failure, ! Monitor phase failure &
Phase sequence & Phase Phase sequence & Phase Phase sequence & Phase Phase asymmetry, Over Phase asymmetry
asymmetry asymmetry asymmetry voltage & Under voltage ! LED indication : Relay ON
FEATURES ! LED indication : Relay ON ! LED indication : Relay ON ! LED indication : Power ! LED indication : Power ! Slim space saving design
! Slim space saving design ON & Trip ON & Trip
! DIN rail & Wall mount
! Monitors under & over voltage ! Monitor under & over voltage
! Monitors phase sequence & failure ! Monitor phase sequence & failure
! LED indication : Power ON, Fault condition ! LED indication : Power ON, Fault condition
FEATURES ! Space saving design
Under voltage : 310 to 405V AC Under voltage : 170 to 224V AC Under voltage : 310 to 405V AC
Over voltage : 425 to 520V AC Over voltage : 236 to 290V AC Over voltage : 425 to 520V AC
MODES Phase sequence : YES Phase sequence : YES Phase sequence : YES
Phase failure : YES Phase failure : YES Phase failure : YES
Reset : Auto reset on removal of fault condition Reset : Auto reset on removal of fault condition Reset : Auto reset on removal of fault condition
Trip time delay : 0.2 to 10sec Trip Delay : 0 to 10s (For under voltage and over voltage)
TIME RANGES Power On delay : 400msec : Instantaneous (For phase failure & phase sequence)
ELECTRICAL
3Ø - 3W
CONNECTION
OPERATING VOLTAGE 310 to 520V AC (L - L) 170 to 290V AC (L - L) 310 to 520V AC (L - L)
900VPR-2 900VPR-BL-U
90(H) x 35(W)mm 90(H) x 35(W)mm
! Monitors under voltage, Over voltage, Under frequency, Over ! Monitors under voltage, Over voltage, Under frequency, Over frequency,
frequency, Phase asymmetry, Phase failure and Phase sequence Phase asymmetry, Phase failure, Phase sequence and Neutral loss
FEATURES ! Two separate alarm relays ! Two alarm relays with NO or NC operation selectable
! LED indication : Power ON, Fault condition ! LED indication : Fault condition
MEASUREMENTS Under / Over voltage, Under / Over frequency, Phase asymmetry, Phase failure, Phase sequence, (Neutral failure applicable only for 900VPR-BL-U)
SUPPLY VOLTAGE Self powered, Operating voltage : 280 to 520V AC (L - L) , 160 to 300V AC (L - N) 85 to 270V AC / DC
(AC : 50 / 60 Hz)
VPRA2M VPRD2M
90(H) x 35(W)mm 90(H) x 35(W)mm
! Monitors under voltage, Over voltage ! Monitors under voltage, Over voltage
! Monitors phase asymmetry, Phase failure, Phase sequence ! Monitors phase asymmetry, Phase failure, Phase sequence
! Adjustable over and under voltage trip level ! Adjustable switching hysteresis
FEATURES ! Adjustable trip time delay ! One relay with two change over alarm relay operation
MEASUREMENT Under voltage, Over voltage, Phase failure, Phase sequence, Phase asymmetry
Separate LED indications for Power ON, Phase failure, Under voltage,
DISPLAY Over voltage, Phase sequence, Phase asymmetry
3 digits LCD
ELECTRICAL 1Ø - 2W, 3Ø - 4W
CONNECTION
Under voltage : 55 to 95% of Un [127 to 219V AC (L - N)] Under voltage : 127 to 219V AC (L - N)
TRIP SETTING Over voltage : 105 to 125% of Un [242 to 288V AC (L - N)], Phase asymmetry : > 10% Over voltage : 242 to 288V AC (L - N), Phase asymmetry : 5 - 30 %
Power ON delay : 0 to 15sec, Trip time delay : 0 to 15sec Power ON delay : 0.5 to 300sec, Trip time delay : 0 to 300sec
TRIP TIME SETTING Recovery time delay : 5sec ± 200ms, Phase sequence trip delay <250msec Recovery time delay : 0 to 300sec, Phase sequence trip delay <150msec
HYSTERESIS Voltage : 7V (±2V) of trip voltage Voltage : 1.0V - 99.9V, Asymmetry : 2 to 20%
ACCURACY Trip setting : ±5% of F. S., Time setting : ±10% of F. S. Voltage : ±1% ±2 digits, Time setting : ±5% of settings ± 150ms
OUTPUT CONTACT 2 C/O (DPDT)
OUTPUT RATING NC : 5A@250V AC, NO : 5A@250V AC
SUPPLY VOLTAGE Self powered, Nominal input voltage (Un) : 230V AC (L - N), Operating voltage : 127 to 288V AC (L - N)
(AC : 50 / 60 Hz)
MEASUREMENTS Under current, Over current (Current asymmetry applicable only for 900CPR-3)
! Monitor true RMS earth leakage current up to 30A ! Monitor true RMS earth leakage current up to 30A ! Monitors True RMS earth leakage current in 1Ø
in 1Ø & 3Ø system in 1Ø & 3Ø system & 3Ø system
! CBCT connection monitoring ! CBCT Open or short circuit detection ! Inbuilt CBCT
FEATURES ! Test and reset via Front / Remote
! Sensitivity and time delay adjustable ! Test and reset function
! Two separate alarms relays with NO or NC
operation selectable ! Test and reset function via Front / Remote
MEASUREMENT Earth leakage current (Via external CBCT) Earth leakage current (Internal CBCT)
DISPLAY 3 digit LCD with backlight, 2 LED for trip indication 5 LED indication 2 LED indication
ELECTRICAL 1Ø - 2W, 3Ø - 3W, 3Ø - 4W 1Ø - 2W, 3Ø - 4W 1Ø - 2W, 3Ø - 3W, 3Ø - 4W
CONNECTION
TRIP SETTING 30mA to 30A 30mA to 30A 75% of 30mA or 300mA
Power ON delay : 0.5 to 99.9 sec, Trip time delay : 0 to 9 sec
TIME RANGES Trip time delay : 0 to 99.9 sec, Delay On release : 0 to 99.9 sec (NA when In=0.03A) Reset time : Instantaneous
Current: ±5% of setting, Time (Recovery time, Current : ± 5% of Set Trip current Current: ± 5% of Input current
ACCURACY Trip delay, Power on delay) : ±5% of setting ±200ms Time : ± 5% of set Time + Response time Time: ± 5% of Response time
OUTPUT CONTACT 2 x 1 C/O (SPDT) 1 C/O SPDT
OUTPUT RATING NC : 3A@250V AC, NO : 5A@250V AC NO : 10A@277V AC / 28DC NC : 5A@250V AC, NO : 5A@30V AC
SUPPLY VOLTAGE 230V AC (± 15%)
900EFR-BL-U
90(H) x 35(W)mm
! Earth fault current monitoring
! Two alarm relays with NO and NC operation selectable
FEATURES ! Test and reset via Front / Remote
! LED indication : Fault condition
DESCRIPTION EFCT
CURRENT RATIO 160/1A, 250/1A, 630/1A
RATED BURDEN 1 VA
SIZES (mm) 100 x 25, 140 x 35, 180 x 35, 220 x 50
WLCA2M1 WLCA-2M-U-CE
90(H) x 35(W)mm 90(H) x 35(W)mm
! Used for drain & fill control ! Selectable suction and delivery mode in single tank operation
! 3 No's stainless steel prods ! Used for two tank monitoring, Single tank water level monitoring
FEATURES ! Manual start switch facility
! 10A SPDT output (Resistive)
! Trip relay & alarm relay indication
DISPLAY 2 LED indication 4 LED indication
AUXILLARY SUPPLY 85 to 270V AC / DC
TRIP SETTING According to the levels of sensor placed in the water tank
SENSITIVITY 1 Kohms to 200Kohms Auto
TRIP TIME 0.5sec (approx) 2sec
MODE Auto Auto / Manual
ACCURACY NA ±5% + 100msec
OUTPUT CONTACT 1 C/O (SPDT) 1 N /O (Resitive )
OUTPUT RATING 10A@250V AC / 28V DC 5A@ 250 V AC /28V DC
! Stainless steel
! Suitable for conductive liquids
MPR-3M MPR-341-2
90(H) x 52.5(W)mm 96(H) x 96(W)mm
! Single phasing, Phase asymmetry, Phase sequence ! Monitors Over load (As per NEMA Curve ), Over current, Under current, Current
! Under current, Overload trip current asymmetry
! Lock current, Earth fault,
FEATURES ! Test and reset function via Front / Remote ! Phase loss, Phase sequence.
! LED indication: Power ON, Trip relay
! Test & reset function via Front / Remote
DISPLAY 3 LED indication 7 segment, 4 digits LED
PPRD-4M-3-415V PPRA-4M-3-415V
90(H) x 70(W)mm 90(H) x 70(W)mm
! Monitors Over load (As per NEMA Curve), Over current, Under current, ! Monitors over load (As per NEMA Curve), Over current, Under current, Current
Current asymmetry, Lock current asymmetry, Lock current,
! Over voltage, Under voltage ! Over voltage, Under voltage
FEATURES ! Phase loss, Phase sequence, Phase asymmetry ! Phase loss, Phase sequence, Phase asymmetry
! LED indication: Power ON, Trip relay ! LED indication: Power ON, Trip relay
! Test & reset function via Front / Remote ! Test & reset function via Front / Remote
DISPLAY 7 segment, 3 digits LED 4 LED & 4 knob for variable setting
DESCRIPTION MPCT
CURRENT RANGE 10A, 40A, 80A
TPRA2M1-1-U-CE
90(H) x 35(W)mm
! PTC input
FEATURES ! LED indication: Power ON, Trip, Open, Short
! DTDT relay output
LED INDICATION Green: Power ON indication, Yellow : Sensor Indication, Red: Relay status
INPUT TYPE PTC sensor
SENSOR Sensor short : <40 (±1Ω), Sensor trip : ≥3.8KΩ (±150Ω) to <5.5KΩ (±150Ω)
Sensor cut-in : ≤1.5KΩ (±60Ω)
SPECIFICATIONS Sensor healthy : 44Ω (±3Ω) to <3.8KΩ (±150Ω) Sensor open : ≥5.5KΩ (±150Ω) & above
Ordering information
Line Monitoring Relay Earth Fault Relay
PRODUCT CODE OPERATING RANGE CERTIFICATION PRODUCT CODE SUPPLY VOLTAGE CERTIFICATION
600PSR-CE 154 to 500V AC 900EFR-BL-U-CE 85 to 270V AC / DC
800PSR 154 to 500V AC ---
LISTED
900VPR-BL-U-CE 85 to 270V AC / DC
VPRA2M-CE 127 to 288V AC PRODUCT CODE INNER DIAMETER (IN MM) CERTIFICATION
VPRD2M 127 to 288V AC --- CBCT-35-1-CE 35
CBCT-70-1-CE 70
Current Monitoring Relay CBCT-120-1-CE 120
PRODUCT CODE SUPPLY VOLTAGE CERTIFICATION CBCT-210-1-CE 210
900CPR-1-BL-U-CE 85 to 270V AC / DC
CBCT-310-1-CE 310
900CPR-3-1-BL-230V-CE 230V AC (±15%)
900CPR-1-230V 230V AC (±15%)
900CPR-3-230V 230V AC (±15%) Water Level Controller
Earth Leakage Relay PRODUCT CODE SUPPLY VOLTAGE CERTIFICATION
SUPPLY VOLTAGE
(AC : 50 / 60 Hz) 230V AC ±10%
Analog Timers
! Single function - ON delay ! Multi function (13 Functions) ! Star Delta ! 2 Functions
! 10 Time ranges ! Precise analog time setting ! 1 NO for Star & 1 NO for Delta ! 8 Time ranges
FEATURES ! Universal supply voltage
A, B, C, Ci, D, E, F, H,
MODES ON delay I, J, K, Ai, Bi Star - Delta ON delay / Interval
SUPPLY VOLTAGE
240V AC 20 to 240V AC, 12 to 240V DC 230V AC 230V AC, 24V AC / DC 20 to 240V AC, 12 to 240V DC
(AC : 50 / 60 Hz)
A - ON delay, B - Interval, C - Repeat cycle equal OFF first, Ci - Repeat cycle equal ON first, D - Pulse output 500ms fixed, E - Delay on break,
600XU F - Delay on make / Delay on break, H - Interval after break, I - Single shot, J - Retriggerable single shot, K - Latching relay,
Modes
Ai - Delay on break with Totalise, Bi - Interval with Totalise
OUTPUT CONTACT 2 C/O DPDT 2 C/O DPDT 1 C/O SPDT 1 C/O SPDT
CONTACT RATING 5A @ 250V AC or 24V DC
SUPPLY VOLTAGE 230V AC & 24V AC / DC 230V AC, 415V AC
20 to 240V AC, 12 to 240V DC
(AC : 50 / 60 Hz)
! Star Delta ! Asymmetrical Cyclic ! Forward Pause Reverse ! True Power OFF Delay
FEATURES ! 1 C/O Relay each for Star & Delta ! 6 Time ranges ! 1 C/O Relay each for Forward & ! Fixed time range (180sec)
Reverse
MODES Star - Delta Asymmetrical Cyclic ON first or OFF first Forward - Pause - Reverse True Power OFF Delay
Run up time : 30 / 60sec 1 / 10sec / min / hr ON time : 1 / 2 / 4 / 8min
TIME RANGES Change over : 50 / 100msec 180sec
for both ON & OFF time Pause time : 10 / 20 / 40 / 80s
ON time : 6s
RESOLUTION --- 0.1sec 7.5sec
Pause time : 0.1s
Setting : ±10% of F.S.
ACCURACY Setting : ±0.5% or 50ms, Repeat : ±5% of F.S. Repeat : ±2% or 100ms
1 C/O Relay each for
OUTPUT CONTACT 1 C/O Relay each for Star & Delta 2 C/O DPDT
Forward & Reverse
2 C/O DPDT
TIME RANGE 1 / 3 / 10 / 30sec / min / hr 1 / 10sec / min / hr for both ON & OFF time 3 / 10 / 30 / 60sec / min
SUPPLY VOLTAGE
20 to 240V AC, 12 to 240V DC 230V AC, 24V AC / DC
(AC : 50 / 60 Hz)
18 www.selec.com TIMERS
Digital Timers
RESOLUTION 0.01sec
A - ON delay, B - Interval, C - Asymmetrical cyclic OFF first, D - Asymmetrical cyclic ON first, E - Repeat cycle equal OFF first, F - Repeat cycle equal ON first,
Modes 600DT H - Pulse output, J - Delay on break, K - Delay on make/Delay on break, L - Interval after break, P - single shot,Q - Retriggerable single shot, R - Latching relay,
T - Delay on break with Totalise, U - Interval with Totalise
SET POINT Single set point Dual set point Single set point
ON delay / Interval / Cyclic ON first / Cyclic ON delay / Interval / Cyclic ON first /
MODES ON delay / Interval / Cyclic ON first / Cyclic OFF first OFF first / Forward-Pause-Reverse / Cyclic OFF first (Start up delay & no.
Instantaneous + Delayed / Timer / Batch of cycles programmable
for cyclic mode)
9.99 / 99.9 / 999sec, 9.59min : sec, 99.99 / 999.9 / 9999sec, 99.59min : sec, 99.99sec, 999.9sec, 99.59min : sec,
TIME RANGES 99.9 / 999min, 9.59hr : min, 99.9 / 999hr 999.9 / 9999min, 99.59hr : min, 999.9 / 9999hr 99.59hr : min, 999.9hr
RESOLUTION 0.01sec
RESET/START INPUT Start : Gate / Pulse start (Programmable) Reset : Front panel, Remote reset, On power interruption
19 www.selec.com TIMERS
Time Interval Meter / Hours Meters
Ordering information
Digital Time Switches Digital Timers
PRODUCT CODE SUPPLY VOLTAGE CERTIFICATION PRODUCT CODE SUPPLY VOLTAGE CERTIFICATION
TS2M1-1-16A-230V V2 230V AC --- 600DT 20 to 240V AC / DC
UL US
TS2M1-1-16A-230V-CE 230V AC 600DT-CU 20 to 240V AC / DC C
LISTED
800XU-CU C US
55XC-P8-CU C US
55XC-T8-CU C US
20 www.selec.com TIMERS
Digital Counters
! Thumbwheel setting ! Counter with rate indicators ! Counter with rate indicator
! Auto reset ! Programmable input scaling ! Programmable input scaling
FEATURES ! Battery backup ! Up, Down, Quadrature & Bi-directional modes
! Unidirectional, Bi - directional & Quadrature modes
! Batch counter
! Dual set point
MODES ON delay / Interval / Auto reset ON delay / Interval / Auto reset / Time pulse repeat
RESET Front, Remote, Auto (Optional) Front (user selectable), Remote Front, Remote, Power interruption
MEMORY Yes (Optional) Yes
DIRECTION Up Up, Down, Bi-directional, Quadrature Up / Down
INPUT SPEED 30Hz, 5kHz (Selectable via dip switch) 30Hz, 2.5kHz, 5kHz (Programmable) 30Hz, 5kHz (Programmable)
SCALE FACTOR 0.00001 to 9.99999 x 10n,n= -5, -4, -3, -2, -1, 0, 1, 2
OUTPUT CONTACT 2 C/O DPDT 2 C/O DPDT
CONTACT RATING 5A @ 250V AC or 24V DC 5A @ 250V AC or 24V DC
INPUT NPN, PNP sensor, Potential free contacts NPN / PNP sensor, Potential free contacts, Encoder
SUPPLY VOLTAGE
(AC : 50 / 60 Hz) 230V AC 90 to 270V AC / DC
21 www.selec.com COUNTERS
Rate Indicator Speed Monitoring Relay
RC5100 SMRD4M1
48(H) x 48(W) x 100(D)mm 90(H) x 70(W) x 62(D)mm
DISPLAY 4 digits
COUNTING DIRECTION Up
SUPPLY VOLTAGE
(AC : 50 / 60Hz) 90 to 270V AC / DC
Ordering information
Digital Counters Digital Timer-Counter
PRODUCT CODE SUPPLY VOLTAGE CERTIFICATION PRODUCT CODE SUPPLY VOLTAGE CERTIFICATION
XC22B-4-230 230V AC XTC5400 90 to 270V AC / DC
XC22B-4-AR-M1-230 XTC5400-CU 90 to 270V AC / DC C
®
US
XC1200 90 to 270V AC / DC
Speed Monitoring Relay
XC3200 90 to 270V AC / DC
XC3200-CE 90 to 270V AC / DC PRODUCT CODE SUPPLY VOLTAGE CERTIFICATION
XC2200 90 to 270V AC / DC SMRD4M1-2-U-CE 90 to 270V AC / DC
XC2200-CE 90 to 270V AC / DC
Rate Indicators
LCD / LED Counters
PRODUCT CODE SUPPLY VOLTAGE CERTIFICATION
SUPPLY VOLTAGE RC5100A 90 to 270V AC / DC
PRODUCT CODE CERTIFICATION
Contact Voltage
LXC900A-C YES
LXC900A-V YES
LXC900A-C-CE YES
LXC900A-V-CE YES
PRODUCT CODE SUPPLY VOLTAGE CERTIFICATION
XC410A-1-230 230V AC
XC10D 90 to 270V AC / DC
22 www.selec.com COUNTERS
Temperature Controllers
! TC / RTD input ! Single display, Single set point ! Dual display, Single set point ! Dual display, Single set point
! ON-OFF / PID control (Auto tune / self tune) ! Short depth TC ! Short depth TC ! Short depth TC
! Dual set point
Selectable control output: Relay / SSR ! TC / RTD input ! TC / RTD input ! TC / RTD input
FEATURES !
! Auxiliary output: Relay ! Control output : Relay or SSR ! Control output : Relay or SSR ! Control output : Relay or SSR
DISPLAY 4 + 4 digits, 7 segment LED dual display 3 digits, 7 segment LED single display 3 + 3 digits, 7 segment LED dual display 4 + 4 digits, 7 segment LED dual display
INPUT TYPE Thermocouple (J, K, T, R, S) / RTD (PT100)
0.1 / 10 for TC / RTD inputs
RESOLUTION (fixed 10 for R & S type TC input)
Fixed 10 resolution
ACCURACY For TC input: 0.25% of F.S ±10 ; For R & S inputs: 0.5% of F.S. ±20 (20 min of warm up time for TC inputs); For RTD input: 0.1% of F.S ±10
SETPOINT Dual set point Single set point
CONTROL MODE Auto tune / Self tune PID or ON-OFF
Relay: SPST: 5A resistive @ 230V AC / Relay: SPDT: 10A resistive @ 230V AC / 30V DC or
CONTROL OUTPUT
30V DC or SSR: 12V DC, 30mA SSR: 12V DC, 50mA
AUXILIARY OUTPUT Relay: 5A resistive @ 230V AC / 30V DC
SPECIAL FUNCTIONS Heat cool PID, Dwell timer
SUPPLY VOLTAGE 90 to 270V AC / DC
(AC : 50 / 60 Hz)
! Dual display, Dual set point ! Single display, Single set point ! Dual display, Single set point
! TC / RTD input ! TC / RTD input ! TC / RTD input
! Control output : Relay or SSR ! Control output: Relay or SSR ! Control output: Relay or SSR
FEATURES
! Auxiliary output : Relay
! Dwell timer, Heat cool PID
DISPLAY 4 + 4 digits, 7 segment LED dual display 3 digits, 7 segment LED single display 3 + 3 digits, 7 segment LED dual display
RESOLUTION 0.1 / 10 for TC / RTD (fixed 10 for R & S TC) Fixed 10 resolution
For TC inputs : 0.25% of F.S. ±10 ; For R & S inputs : 0.5% of F.S. ±20
ACCURACY (20 min of warm up time); For RTD input: 0.1% of F.S. ±10
AUXILIARY OUTPUT Relay: SPDT (SPST for TC544A): 5A resistive @ 230V AC / 30V DC ---
CH403A CH403
36(H) x 72(W)mm 36(H) x 72(W)mm
! 2½ Digits single display ! 3 Digits single display
! NTC input type ! Auto / Manual defrost management
! Restart time delay ! High / Low temperature alarms
FEATURES ! Auto / Manual defrost selection
! Door open mode
! Control output: Relay
! Cyclic timer application for auxiliary output ! Auxiliary output: Relay & SSR
Process Indicators
90 to 270V AC / DC C US
COMMUNICATION
PRODUCT CODE OUTPUT 1 OUTPUT 2 OUTPUT 3 (RS485) SUPPLY VOLTAGE CERTIFICATION
OUTPUT 1
PRODUCT CODE OUTPUT 2 SUPPLY VOLTAGE CERTIFICATION
RELAY SSR
DTC503 RELAY --- --- 90 to 270V AC / DC ---
DTC231 RELAY --- --- 90 to 270V AC / DC ---
DTC331 RELAY --- --- 90 to 270V AC / DC ---
PID528-1 RELAY -- RELAY 90 to 270V AC / DC ---
PID528-1 V2-CE RELAY -- RELAY 90 to 270V AC / DC
DTC204A-2 RELAY SSR RELAY 90 to 270V AC / DC ---
DTC324A-2 RELAY SSR RELAY 90 to 270V AC / DC ---
TC52-400-J-230 RELAY --- --- 230V AC ---
US
RELAY (10A) SSR (12V DC) PIC152A-VI Universal --- 90 to 270V AC / DC ---
CH403-1-NTC 90 to 270V AC / DC
PIC152A-VI-CE Universal --- 90 to 270V AC / DC
CH403-1-NTC-CU RELAY (10A) SSR (12V DC) 90 to 270V AC / DC C
®
US
! 3.5" LCD with touch screen ! PLC with built in HMI ! PLC with flexible I/O card selection
! Flexible I/O card selection ! Flexible I/O card selection ! Real time clock
FEATURES ! Real time clock ! Real time clock ! Expandable
! Expandable ! Expandable
TFT 3.5" diagonal touch screen, LCD with backlight, 4x16 character display, 7 segment display for slot number & card status.
DISPLAY
Resolution 320x240 Font size 5x7mm Multipurpose LED bank
NO. OF KEYS 5 function keys +1 system key 18 keys (14 user configurable) One key to scroll through different slots
3 I/O slots (Please refer I/O card
I/Os for flexys series)
4 I/O slots (Please refer I/O card for flexys series)
EXP FLEX 2M
90(H) x 35(W)mm
ANALOG INPUTS 3 / 4 / 6 Channels per card (TC, RTD, 0-10V, 0 - 20mA, NTC)
RESOLUTION 12 Bits
27 www.selec.com PLCs
Compact Series - UNIX & TWIX
! Compact PLC with built in HMI ! Compact PLC with built in HMI ! Compact PLC with built in HMI
FEATURES ! RS485 MODBUS RTU protocol ! Configurable LED display ! RS485 MODBUS RTU protocol
! RS485 MODBUS RTU protocol
DISPLAY 6 digits red & 4 green digits 7 segment LED 4 + 4 digits red & 6 green digits 7 segment LED 3 + 4 digits red & 4 green digits 7 segment LED
! Compact PLC with built in HMI ! LED indications for input & output ! Compact PLC with built in HMI
! 2 Line 8 character LCD ! RS485 MODBUS RTU protocol ! 2 Line 8 character LCD
FEATURES ! Real time clock** ! Real time clock**
! RS485 MODBUS RTU protocol ! RS485 MODBUS RTU protocol
*Voltage Analog Inputs can be configured as Digital Inputs **Please refer Datasheet for exact Order code
28 www.selec.com PLCs
PLC - Fixed IO Configuration
SP112-GT70 SP3-GT35
149(H) x 203(W)mm 96(H) x 96(W)mm
! 7" Touch screen ! Data logging functionality ! 10 Password levels
! Ethernet / Serial communication ! Update program by USB flash ! Serial printing
FEATURES ! User management ! Multiple communication protocols ! Data logging
! Recipe management ! In-Built symbol library ! Built in buzzer
! Recipe management
DISPLAY 7" Diagonal resistive touch screen 3.5" Diagonal resistive touch screen
RESOLUTION 800 x 480 320 x 240 pixels
USER MEMORY 128M Flash + 64M DRAM 16 MB
DATA LOGGING Yes 2 GB (External SD card)
COMM. PORT 1 RS485 MODBUS RTU protocol Master port - RS485 MODBUS RTU protocol
COMM. PORT 2 RS232 MODBUS RTU protocol, Multiple communication protocols Slave port - RS232 MODBUS RTU protocol
COMM. PORT 3 10M / 100M Self adaptation Serial printer ESC / PAUSE protocol
USB SLAVE USB 2.0
KEYS 5 Function keys + 1 System key
RTC Yes Yes
BACKUP BATTERY 3V CR2032
OPERATING
0° - 50° C 0° - 55° C
TEMPERATURE
SUPPLY VOLTAGE 24V DC 18 - 30V DC
29 www.selec.com PLCs
Annunciator
AN-8-0-0-230V
147(H) x 76(W)mm
! 8 Programmable windows
! 6 Colour selection
FEATURES
! RS485 MODBUS RTU protocol
DIGITAL OUTPUTS 2
Accessories - SMPS
30 www.selec.com PLCs
Accessories - Relay Modules
! LED and freewheeling diode across coils ! RS485 Comm. over MODBUS-RTU
! Reverse polarity protection ! Selectable baudrate and slave ID
FEATURES ! Jumpers for coil looping ! Pluggable relays
! Pluggable relays
NO. OF CHANNELS 4 8 4 8 8
Expansion adapter for Adapter for directing RJ25 to open Both Side RJ45 type Both Side RJ25 Type
DESCRIPTION terminal and also for network looping
DB9 to RJ25 cable
connector
MM303X PLCs Connector
31 www.selec.com PLCs
Ordering Information
Flexible IO Solution Compact Series
PRODUCT CODE CERTIFICATION PRODUCT CODE CERTIFICATION
FL–GT35–DI04-PS-230V DIGIX-1-0-0-24VDC-B in process
FL-GT35-LG-1-0-1 DIGIX-1-1-1-230V
FL–TX4–DI04–PS–230V DIGIX-2-1-0-24VDC in process
TWIX-3-24VDC in process
Fixed IO Configuration
MM1015-230V in process
PRODUCT CODE CERTIFICATION
MM3030-2 in process Human Machine Interface
MM3030-4 in process PRODUCT CODE CERTIFICATION
MM3032-2-0-0-230V-V2 in process SP112-GT70-ET-CE in process
SP3-GT35 in process
FL-SC-AI03-NTC-AI03-I 3 Channel analog input – NTC, 3 channel analog input – Current card in process
FL-SC-AI03-U-AO02-U 3 Channel analog input - Universal, 2 Channel analog output - Universal card in process
RAL 3 Way
Not available for enclosure dimensions 45x30x30.
ENC1-1758057-3-CE 175 80 57
ENMP-758057
ENMP-1258057
C
ENMP-10010081
ENMP-2508057
ENMP-12012281
ENMP-12012291
ENMP-14014091 Applications:
CCTV, Solar, Control Stations,
ENMP-22012081 Street Lights, Junction Box,
Electrical Connection Box and
ENMP-22012091 PCB Enclosures etc.
ENMP-26016091
102 92 52 46.5
Front bezel Panel cutout
Front bezel Panel cutout
72 67.5
Front bezel Panel cutout 144 138
96 92
48 45.5
Front bezel Panel cutout
Front bezel Panel cutout
140 72
(214x160mm) (140x93.4x72mm)
160
142.9
93.6
93.6
76
214 196.9
17.6
Front bezel Panel cutout
34.50 29
51.85
51.85
63.5
63.5
63.5
76 71
Front bezel Panel cutout
ANALOG METERS
(AM - I / AM - V / AM - DIRECT TYPE AMMETER / AM - PF / AM - HZ)
(72x72mm, 96x96mm)
1
a
TS1W1-1-20A
h
f
d
g
e
600 800
44
SERIES SERIES 22.5
100.5
45
76.85
67.5
35.3
90
35
17.5
105.5
60
45
45
90
90
66.3
60
MPR-3M ELCTR35
45 70
1 2 3 4 5 6 7 8 9
73
27
105
64
52.5 90 35
Top View
74
Front View