Blind Flange Thickness Calculation

The document provides equations and values for calculating the minimum wall thickness (Tm) required for a flange with an inside diameter (dg) of 35.252 inches under a design gauge pressure (P) of 1480.8 PSI. It calculates Tm as (dg x square root of (3P/16SxE)) + C, where S is the allowable stress value of 23300 PSI, E is the weld joint efficiency factor of 1, and C is the corrosion allowance of 0 inches. Using these values, it determines the minimum required wall thickness (Tm) is 3.848 inches.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLS, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
427 views3 pages

Blind Flange Thickness Calculation

The document provides equations and values for calculating the minimum wall thickness (Tm) required for a flange with an inside diameter (dg) of 35.252 inches under a design gauge pressure (P) of 1480.8 PSI. It calculates Tm as (dg x square root of (3P/16SxE)) + C, where S is the allowable stress value of 23300 PSI, E is the weld joint efficiency factor of 1, and C is the corrosion allowance of 0 inches. Using these values, it determines the minimum required wall thickness (Tm) is 3.848 inches.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLS, PDF, TXT or read online on Scribd
You are on page 1/ 3

Unit

Tm = Flange minimum wall thickness

dg = 35.252 Inch Inside Diameter of Gasket

P = 1480.8 PSI Design gauge pressure

E = 1 Weld joint Efficiency factor

S = 23300 PSI Allowable Stress value of material

C = 0 Inch Corrosion Allowance

Gasket ID Pressure
6 2500# 9 6171.3
900# 8.312 2222

8 900# 10.625 2222

10 1500# 10.75 3702.8

12 900# 15 2222
1500# 15 3702.8
2500# 16 6171.3

14 900# 16.5 2222

18 900# 21 2222

24 900# 27.25 2222

36 600# 35.252 1480.8


Tm = ( dg √ 3P / 16 S E ) + C

Tm = ( 35.25 √ 4442.4 / 372800 ) + 0

= ( 35.25 x 0.109161848 ) + 0 SA-36


SA-516
= 3.848 inch

= 97.74 mm

SA-36 SA-516
59 51
33 29

42 37

54 48

59 51
76 66
104 91

65 57

82 72

106 93

112 98
Allowables
17800 PSI
23300 PSI