Data sheet

H-2000-2285-02-B

OMI

The OMI is an optical transmitter/receiver/interface, which conveys and processes


signals between an inspection probe and the CNC machine control
The OMI is an alternative to the OMM receiver + MI 12 interface arrangement

2 3 4
1
5

6
6
6 CNC
machine
7
control

OMI STATUS LEDs FEATURES


Visual indication of system status is provided by LEDs. ● Toughened glass window
1. LED (Yellow) - START signal status. ● Sealed to IPX8 for machine tool environment
Flashes when start signal is transmitted to probe.
● Internal range selection switches
2. LED (Red) - Low battery life.
Reception (RX) 25%, 50% or 100%
Flashes on and off when probe battery
Transmission (TX) 50% or 100%
voltage falls below a set level.
Both factory set to 100%.
3. LED (red, green) - Probe status.
Lit when OMI is powered. ● Machine start/auto start selection switch
Green - Probe seated. Machine start Machine control M code command.
Red - Probe triggered or an error has occured. Auto start Start signal at one second intervals.
Factory set to machine start.
4. LED (red) - Error.
Lit when error condition exists. ● Outputs
e.g. optical beam obstructed/probe out of optical Probe status Skip Low battery Error
range/probe switched off/battery exhausted.
5. LED (red, yellow, green). Probe status Skip Low battery Error
Signal strength received.
OMI OPTIMUM POSITION SETTING
Red - No signal, or signal too weak.
To assist finding the optimum position for the OMI
Yellow - Marginal signal, system may/maynot
during system installation, signal strength received
operate.
is indicated on the red/yellow/green LED (item 5).
Green - Good signal, system will operate correctly.
WARNING
6. LED (clear x 3 banks).
If two systems are operating in close proximity, take care
Transmit control signals to the probe.
to ensure that signals transmitted from the OMP on one
7. Sealing gland .
machine, are not received by the OMI on the other machine,
8. Conduit.
and vice versa. The OMI may have to be shielded from
9. Cable. direct light sources.
Renishaw plc T +44 (0)1453 524524
New Mills, Wotton-under-Edge, F +44 (0)1453 524901
Gloucestershire GL12 8JR E [email protected]
United Kingdom www.renishaw.com

Installation Cable
84 (3.30) dimensions mm (ins) Colour Signal
40 (1.57) 40 (1.57) Red +24 V (supply)
46.7 (1.84)
Black 0 V (supply)

40 (1.57)
White Start (+ve)
Brown Start (–ve)

45 (1.77) Grey Output B (–ve)

63 (2.48) Yellow Skip (output B)


Orange Output B (+ve)
Blue Outputs A (–ve)
Steel tube Green Error (outputs A)
Ø12 (0.47) Violet Low bat (outputs A)
or
Flexible conduit Turquoise Probe status (outputs A)
16 (0.63) Ø11 (0.43) Pink Outputs A (+ve)
Grey/black Machine earth

MOUNTING BRACKET Standard cable - 8m long


allows OMI directional setting Screened, 12 core, 7/0.1
Ø5.1 mm x 8 metres long
25 25 (Ø0.2 in x 26 ft long)
19 (0.75)

(0.98) (0.98)
Extension cable - 25m long
Screened, 12 core, 7/0.2
Ø6.9 mm x 25 m long
38 (1.50)

(Ø0.27 in x 82 ft long)

+
Standard cable Extension cable
3 holes Ø6.4 (0.25) 3 grip protrusions 8 m (26 ft) 25 m (82 ft)
100.5 (3.95)


33 m (108 ft) MAXIMUM
2.0
(0.98) (1.18)

(0.08)
30

● Install OMI with cable exiting from


lower side for good coolant run off.
25

6 Holes ● Cable entry to the OMI is sealed


Adjustable Ø5.3 (0.20) with a gland.
setting
(1.77)

● Cable protection against physical


45

damage should be provided by


either steel tube or flexible conduit.
45 (1.77) 45°
2.0 ● The conduit adaptor supplied by
(0.08) Renishaw, accepts either steel tube
or flexible conduit.
90 (3.54)
● Route the cable away from potential
Paired holes permit OMI mounting sources of electro magnetic
in alternative orientation interference.
● Maintain screen through cable joins.

Parts list - Please quote the Part No. when ordering equipment
Type Part No. Description

OMI A-2115-0001 OMI complete with cable (screened) 8 m (26 ft) long.
Extension cable M-2115-0046 Extension cable (screened) 25 m (82 ft) long.
Mtg bracket A-2033-0830 Mounting bracket complete with fixing screws, washers and nuts.
Window A-2115-0002 Window kit for OMI
PG9 adaptor M-2008-0189 PG9 cable gland adaptor.