Battery (New) Run Time Calculator

This document contains calculations to estimate battery capacity and run time for downhole tools based on input telemetry parameters and job details. It finds that Battery 1 would be drained after 75.4 circulating hours, with 0% capacity left, while Battery 2 would have 85% capacity remaining after 25.6 circulating hours. It also provides statistics on data transmission rates and pulsing performance.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLS, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
59 views7 pages

Battery (New) Run Time Calculator

This document contains calculations to estimate battery capacity and run time for downhole tools based on input telemetry parameters and job details. It finds that Battery 1 would be drained after 75.4 circulating hours, with 0% capacity left, while Battery 2 would have 85% capacity remaining after 25.6 circulating hours. It also provides statistics on data transmission rates and pulsing performance.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLS, PDF, TXT or read online on Scribd
You are on page 1/ 7

Battery Capacity and Run Time Calculator 11741 RevA

Battery Performance and Telemetry Statistics


Calculations based on APS TimeBase2
STEP 1: Enter the Pulser Telemetry Parameters Below (Yellow) Currently Supported MPT Data Rates
0.75
MPT Pulse Width (Seconds): 1.00 1.00
1.25
Non-Rotating Formats Rotating Formats 1.50
1.75
ReSync ReSync
Step Repeat FID Transmit Time/Line(min) Step Repeat FID Transmit Time/Line(min) 2.00
ON/OFF ON/OFF
1 1 off 0 2.65 1 1 on 0.00 2.25
2 2 off 27 7.75 2 1 on 0.00 2.50
3 255 on 25 726.75 3 1 on 0.00 2.75
4 1 on 0.00 4 1 on 0.00 3.00
5 1 on 0.00 5 1 on 0.00

Loop Back 3 Loop Back

Time to make 1'st pass thru table 737.15 0.00


Time for each loopback pass thru table 726.75 0.00

STEP2: Enter the Job Related Information Below (Yellow)


Total Pulsing Not Pulsing
Total number of circulating hours 101.0 Non-Rotating Circ Hours 16.2 16.2 0.0
% of circulating hours rotating (0 - 100%): 84% Rotating Circ Hours 84.8 0.0 84.8
Hours the tool is powered up without circulating: 10.0

Downhole temperature (0 - 200C): 52


Assumed ROP (feet/hour): 26

Battery1 capacity on job start-up (0 - 100%): 44%


Battery2 capacity on job start-up (0 - 100%): 100%

STEP 3: Read Battery Capacity and Run Time Results (Blue)

Capacity left in Battery1 after the job (0 - 100%) 0.0% 100.0% Battery1 capacity used
Capacity left in Battery2 after the job (0 - 100%) 85.0% 15.0% Battery2 capacity used
Circulating hours run on Battery1 75.4
Circulating hours run on Battery2 25.6
% of power consumed by the electronics 89.6%
% of power consumed by pulser 10.4%

STEP 4: Read the Data Telemetry Statistics Below (Blue)


4 bit 8 bit Non-Rotating Rotating
Time to the first Toolface after Flow On (minutes) 2.1 2.3 Continuous Gamma Transmit Rate (seconds) 0.0 0.0
Average Continuous Toolface Update Rate (seconds) 28.5 Gamma frequency (gamma points/foot) 0.00 0.00
Gamma period (feet/gamma point) 0.00 0.00

J. LaRosa
File: 466973981.xls
Page 1 of 7 10/06/06
Sheet: Main Screen
password: aps
Battery Capacity and Run Time Calculator 11741A

TOOL CONFIGURATION

Flow On Detect Time (Seconds) 40


MPT Transmit Delay (Seconds): 32
MicroTesla Sensor (y/n) y
Brushless Motor (y/n) n
Joules per pulse 30
Joules per re-open 10

Circulating Not Circulating


Installed (mA) (mw) Powered-up (mA) (mw)
Encoder - 30 y 30 960 y 30 960
Motion Control -35/8 y 35 1120 y 35 1120
FlowStat - 15 y 6 192 y 15 480
Rotation Sensor - 18 y 18 576 y 18 576
Dir Sensor & power supply - 40 y 40 1280 n 0 0 standby of 10 for Dir sensor is for RSS only
Gamma Sensor - 35 n 0 0 y 0 0

Total mA / mW 129 4128 98 3136


Total A / W 0.129 4.13 0.098 3.14

PULSER PERFORMANCE SUMMARY


Non Rotating Rotating
# Pulses Transmit Transmit AVG Pulses # Pulses Transmit Transmit AVG Pulses
Time Time per Hour Time Time per Hour
(Minutes) (Hours) (Minutes) (Hours)
1'st pass thru the table 4654 737.15 12.29 378.81 0 0.00 0.00 0.00
Successive passes thru the table 4590 726.75 12.11 378.95 0 0.00 0.00 0.00

PULSER POWER CONSUMPTION


Pulse Width mA per pulse Joules per pulse Joules per Re-Open Re-open period (minutes) Re-open events per hour
0.75 0.000967 30.00 10.00 2.25 26.67
1.00 0.000967 30.00 10.00 2.25 26.67
1.25 0.000967 30.00 10.00 2.25 26.67
1.50 0.000967 30.00 10.00 2.25 26.67
1.75 0.000967 30.00 10.00 2.25 26.67
2.00 0.000967 30.00 10.00 2.25 26.67
2.25 0.000967 30.00 10.00 2.25 26.67
2.50 0.000967 30.00 10.00 2.25 26.67
2.75 0.000967 30.00 10.00 2.25 26.67
3.00 0.000967 30.00 10.00 2.25 26.67

Ah / Joules consumed per pulse 0.000966962 30.00 10.00 2.25 26.67

File: 466973981.xls J. LaRosa


Page 2 of 7
Sheet: Tool and Pulser Config Screen 10/06/2006
Battery Capacity and Run Time Calculator 11741A

Non-Rotating circulating hours 16.2


Rotating circulating hours 84.8

Nominal battery voltage 32.0


Battery1 Ah Rated Capacity 24.0
Battery1 temp derating factor 110.42%
Battery1 Available Ah 11.7
Battery1 Available Joules 1,343,232

Battery2 Ah Rated Capacity 24.0


Battery2 temp derating factor 110.42%
Battery2 Available Ah 26.5
Battery2 Available Joules 3,052,800

Joules consumed per pulse 30.0


Total Non-Rotating Pulses 6,122
Total Rotating Pulses 0
Total Pulses per Job 6,122

Joules consumed per re-open event 10.0


Total re-open events 266.67

Joules consumed by the pulser while circulating 183,663 Total joules consumed by electronics 1,613,837
Joules consumed by electronics while circulating 1,500,941 Total joules consumed by the pulser 186,330
Joules consumed by the electronics while not circulating 112,896
Joules consumed by the pulser re-open events 2,667 % of power consumed by the electronics 89.65%
Total Joules consumed per job 1,800,167 % of power consumed by pulser 10.35%

Correction factor 0%

File: 466973981.xls J. LaRosa


Page 3 of 7
Sheet: Battery and Pulser Calcs 10/06/2006
Battery Capacity and Run Time Calculator 11741A

MPT Pulse Width (Seconds): 1.00

ReSync FID Data Pulser Pulser Pulser Cumlative Transmit Transmit Total Line Elapsed Time Time to 1'st Time to 1'st Time to 1'st TF per TF per Gamma Gamma
INITIAL PASS THROUGH THE ReSync
Repeat FID Pulses Pulses Pulses Movements Movements Per Movements Per Pulser Time 1'st Time Per Transmit From Start 4 bit value 8 bit value 12 bit value FID line per FID per line
TABLE OFF/ON 1'st Pass Repeat Line Movements Pass Repeat Time (Sec)
1 1 OFF 0 4 2 12 18 0 18 18 159 0 159 159 55.500 66.000 77 1 1 0 0
2 2 OFF 27 4 2 20 26 20 46 64 255 210 465 624 215 225 236 10 20 0 0
3 255 ON 25 4 2 12 18 4572 4590 4654 171 43434 43605 44229 521 531 701 6 1530 0 0
UNKNOWN FID 4 1 ON 0 0 0 0 0 0 4654 0 0 0 44229 0 0 0 0 0 0 0
UNKNOWN FID 5 1 ON 0 0 0 0 0 0 4654 0 0 0 44229 0 0 0 0 0 0 0

Loop Back 3

Totals For First Pass Thru the Table 4654 44229

ONE PASS THRU THE TABLE Repeat ReSync FID ReSync FID Data Pulser Pulser Pulser Cumlative Transmit Transmit Total Line Elapsed Time
STARTING AT THE LOOPBACK OFF/ON Pulses Pulses Pulses Movements Movements Per Movements Per Pulser Time 1'st Time Per Transmit From Start
POINT 1'st Pass Repeat Line Movements Pass Repeat Time (Sec)
1 1 OFF 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
2 2 OFF 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
3 255 ON 25 4 2 12 18 4572 4590 4590 171 43434 43605 43605 6 1530 0 0
4 1 ON 0 0 0 0 0 0 4590 0 0 0 43605 0 0 0 0
5 1 ON 0 0 0 0 0 0 4590 0 0 0 43605 0 0 0 0

Totals for Each Additioanl Pass Thru the Table 4590 43605 6 1530 0 0

VALVE OFF
Valve Off Time (seconds): 12.00

Sync Pulses 1'st pass thru the table taskes: 737.15 Min
Number Pulses: 4 Each additional pass thru the table taskes: 726.75 Min
On Time (seconds): 1.00 Number of non-rotating circulating hours 16.16 Min
Off Time (seconds): 2.00 Number of additional passes made thru the table -0.99
Sync Time (seconds): 12.00 Amount of time making additional passes thru the table -720.99 HRS
Total amount of time spent non-rotating and pulsing 16.16 HRS
FID
FID Time (seconds): 21.00

DATA
Time Slot (Seconds): 0.50
Time Slots per Nybble 21
Nybble Time (Seconds): 10.50
Bits per nybble 4
Bits per second 0.38
Seconds per bit 2.63
Time to send 4 data bits (seconds): 10.50
Time to send 8 data bits (seconds): 21.00
Time to send 12 data bits (seconds): 31.50

File: 466973981.xls J. LaRosa


Page 4 of 7
Sheet: Non-Rotating FIDs Calculator 10/06/2006
Battery Capacity and Run Time Calculator 11741A

MPT Pulse Width (Seconds): 1.00

ReSync FID Data Pulser Pulser Pulser Cumlative Transmit Transmit Total Line Elapsed Time Time to 1'st Time to 1'st Gamma Gamma
INITIAL PASS THROUGH THE ReSync
Repeat FID Pulses Pulses Pulses Movements Movements Per Movements Per Pulser Time 1'st Time Per Transmit From Start 8 bit value 12 bit value per FID per line
TABLE OFF/ON 1'st Pass Repeat Line Movements Pass Repeat Time (Sec)
UNKNOWN FID 1 1 ON 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
UNKNOWN FID 2 1 ON 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
UNKNOWN FID 3 1 ON 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
UNKNOWN FID 4 1 ON 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
UNKNOWN FID 5 1 ON 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

Loop Back 0

Totals For First Pass Thru the Table 0 0 0.00

ONE PASS THRU THE TABLE Repeat ReSync FID ReSync FID Data Pulser Pulser Pulser Cumlative Transmit Transmit Total Line Elapsed Time Time to 1'st Time to 1'st
STARTING AT THE LOOPBACK POINT OFF/ON Pulses Pulses Pulses Movements Movements Per Movements Per Pulser Time 1'st Time Per Transmit From Start 8 bit value 12 bit value
1'st Pass Repeat Line Movements Pass Repeat Time (Sec)
1 1 ON 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
2 1 ON 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
3 1 ON 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
4 1 ON 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
5 1 ON 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

Totals for Each Additioanl Pass Thru the Table 0 0 0.00


0 0

VALVE OFF
Valve Off Time (seconds): 12.00
1'st pass thru the table taskes: 0.00 Min
Sync Pulses Each additional pass thru the table taskes: 0.00 Min
Number Pulses: 4 Number of non-rotating circulating hours 84.84 Min
On Time (seconds): 1.00 Number of additional passes made thru the table 0.00
Off Time (seconds): 2.00 Amount of time making additional passes thru the table 0.00 HRS
Sync Time (seconds): 12.00 Total amount of time spent rotating and pulsing 0.00 HRS

FID
FID Time (seconds): 21.00

DATA
Time Slot (Seconds): 0.50
Time Slots per Nybble 21
Nybble Time (Seconds): 10.50
Bits per nybble 4
Bits per second 0.38
Seconds per bit 2.63
Time to send 4 data bits (seconds): 10.50
Time to send 8 data bits (seconds): 21.00
Time to send 12 data bits (seconds): 31.50

File: 466973981.xls J. LaRosa


Page 5 of 7
Sheet: Rotating FIDs Calculator 10/06/2006
Battery Capacity and Run Time Calculator 11741A

FID Number of Data Bits Data Words toofaces toolface gamma gamma
Data Pulses Sent # bits # bits

1 2 3 4 5 6 7 8 9 10 NON ROTATING MWD


0 12 48 8 12 8 12 4 4 1 8 0 0
1 14 56 12 12 12 12 4 4 1 8 0 0
2 18 72 8 12 8 8 8 8 12 4 4 1 8 0 0
3 20 80 12 12 12 8 8 8 12 4 4 1 8 0 0
4 25 100 8 12 8 12 12 12 12 12 12 1 8 0 0
5 27 108 12 12 12 12 12 12 12 12 12 1 8 0 0
6 10 40 12 8 12 4 4 0 0 0 0
7 11 44 12 12 12 4 4 0 0 0 0
8 5 20 12 8 0 0 0 0
9 6 24 12 12 0 0 0 0
10 8 32 12 8 12 0 0 0 0
11 9 36 12 12 12 0 0 0 0
12 10 40 12 8 4 8 8 1 4 0 0
13 11 44 12 12 4 8 8 1 4 0 0

20 6 24 8 8 8 3 24 0 0
21 6 24 8 8 8 3 24 0 0
22 11 44 8 12 8 8 8 4 32 0 0
23 12 48 12 12 8 8 8 4 32 0 0
24 12 48 8 8 8 8 8 8 6 48 0 0
25 12 48 8 8 8 8 8 8 6 48 0 0
26 20 80 8 8 8 8 8 8 8 8 8 8 10 80 0 0
27 20 80 8 8 8 8 8 8 8 8 8 8 10 80 0 0
28 21 84 8 12 8 8 8 8 8 8 8 8 8 64 0 0
29 22 88 12 12 8 8 8 8 8 8 8 8 8 64 0 0
30 20 80 8 8 8 8 8 8 8 8 8 8 9 72 0 0
31 20 80 8 8 8 8 8 8 8 8 8 8 9 72 0 0
32 21 84 8 8 8 8 12 8 8 8 8 8 9 72 0 0
33 21 84 8 8 8 8 12 8 8 8 8 8 9 72 0 0
34 19 76 8 8 8 8 4 8 8 8 8 8 9 72 0 0
35 19 76 8 8 8 8 4 8 8 8 8 8 9 72 0 0
36 19 76 8 8 8 8 4 8 8 8 8 8 9 72 0 0
37 19 76 8 8 8 8 4 8 8 8 8 8 9 72 0 0
38 11 44 4 4 4 4 8 4 4 4 4 4 10 44 0 0
39 11 44 4 4 4 4 8 4 4 4 4 4 10 44 0 0

100 15 60 8 12 8 12 12 4 4 1 8 1 12
101 16 64 8 12 12 12 12 4 4 1 8 1 12
102 21 84 8 12 8 8 8 8 12 12 4 4 1 8 1 12
103 22 88 8 12 12 8 8 8 12 12 4 4 1 8 1 12
104 28 112 8 12 8 12 12 12 12 12 12 12 1 8 1 12
105 29 116 8 12 12 12 12 12 12 12 12 12 1 8 1 12
106 13 52 12 8 12 12 4 4 0 0 1 12
107 14 56 12 12 12 12 4 4 0 0 1 12
108 8 32 12 8 12 0 0 1 12
109 9 36 12 12 12 0 0 1 12

120 22 88 8 12 8 12 8 12 8 12 8 5 40 4 48
121 22 88 8 12 8 12 8 12 8 12 8 5 40 4 48
122 22 88 8 12 8 12 8 12 8 12 8 4 32 3 36
123 23 92 8 12 12 12 8 12 8 12 8 4 32 3 36
124 22 88 8 12 8 12 8 12 8 12 8 4 32 4 48
125 22 88 8 12 8 12 8 12 8 12 8 4 32 4 48
126 22 88 8 12 8 12 8 12 8 12 8 3 24 3 36
127 23 92 8 12 12 12 8 12 8 12 8 3 24 3 36
128 4 16 4 4 8 2 8 1 8
129 4 16 4 4 8 2 8 1 8
130 16 64 4 8 4 8 8 8 8 8 8 4 24 4 32
131 17 68 4 8 4 8 12 8 8 8 8 4 24 4 32
CHECKSHOT
200 11 44 8 12 8 12 4 1 8 0 0
201 12 48 12 12 8 12 4 1 8 0 0
226 18 72 8 8 8 8 8 8 8 8 8 9 72 0 0
227 18 72 8 8 8 8 8 8 8 8 8 9 72 0 0
260 4 16 16 0 0 0 0
270 3 12 8 4 0 0 0 0 INC(8), Battery
271 4 16 12 4 0 0 0 0 INC(12), Battery
272 6 24 12 8 4 0 0 0 0 AZCX, INC(8), Battery
273 7 28 12 12 4 0 0 0 0 AZCX, INC(12), Battery
ROTATING MWD
140 18 72 12 12 12 12 12 12 0 0 6 72
141 17 68 12 12 12 12 12 8 0 0 5 60
142 27 108 12 12 12 12 12 12 12 12 12 0 0 9 108
143 26 104 12 12 12 12 12 12 12 12 8 0 0 8 96
144 18 72 8 8 8 4 8 8 4 8 8 8 0 0 8 64
145 4 16 8 4 4 0 0 0 0

File: 466973981.xls J. LaRosa


Page 6 of 7
Sheet: FID Lookup Table 10/06/2006
Battery Capacity and Run Time Calculator 11741A

Temperature in C % Capacity Capacity (aH)


0 112.50% 27.00
5 112.92% 27.10 0.2
10 113.33% 27.20 0.4
15 113.75% 27.30 0.6
20 114.17% 27.40 0.8
25 114.58% 27.50
30 113.75% 27.30 0.2
35 112.92% 27.10 0.4
40 112.08% 26.90 0.6
45 111.25% 26.70 0.8
50 110.42% 26.50
55 109.58% 26.30 0.2
60 108.75% 26.10 0.4
65 107.92% 25.90 0.6
70 107.08% 25.70 0.8
75 106.25% 25.50
80 105.83% 25.40 0.2
85 105.42% 25.30 0.4
90 105.00% 25.20 0.6
95 104.58% 25.10 0.8
100 104.17% 25.00
105 103.75% 24.90 0.2
110 103.33% 24.80 0.4
115 102.92% 24.70 0.6
120 102.50% 24.60 0.8
125 102.08% 24.50
130 100.83% 24.20 0.2
135 99.58% 23.90 0.4
140 98.33% 23.60 0.6
145 97.08% 23.30 0.8
150 95.83% 23.00
155 94.17% 22.60 0.2
160 92.50% 22.20 0.4
165 90.83% 21.80 0.6
170 89.17% 21.40 0.8
175 87.50% 21.00
180 85.83% 20.60 0.2
185 84.17% 20.20 0.4
190 82.50% 19.80 0.6
195 80.83% 19.40 0.8
200 79.17% 19.00

File: 466973981.xls J. LaRosa