MTV1000 Multi Purpose Ventilator

Certificate :CE, KFDA, ISO13485, ISO9001

Short Form Specifications of MTV1000

Specification and features subject to change without notice.


7" Color TFT, Touch Screen & Knob.
O2 Blender, Exhalation Drive Line Outlet.
PACV, PSIMV,VACV, VSIMV, Spont+/CPAP, PRVC, Auto.
Apnea Back-up Ventilation.
(Optional Function)
M
SpO2, EtCO2, Proximal Pressure Monitoring and Nebulizer.

Setting Parameter
Predicted Body Weight : 10 to 150kg(Volume)
1 to 150kg(Pressure)
Tidal Volume : 50 to 2500ml
Inspiratory Pressure : 5 to 80 cmH2O
PEEP/CPAP : 0 to 45 cmH2O
Respiratory Rate : 2 to 60 bpm
FiO2 : 21% to 100%
Breathing Circuit Type : Dual Limb & Signle Limb with External Exhalation Valve System)
Nebulizer(Optional) : 10 to 180 minutes

Electrical Requirements
Power : AC : 100-240 VAC, 50/60 Hz (Free voltage)
DC : 10.8V 8.8A, Internal battery
Provides Upto. 180 minutes of normal operation
External DC Supply 12V ~ 16V

© MEKICS CO.,LTD 2015


MEK-001-CA-MT

Head Office Sales Office Customer Service


+82 70 7119 2500 +82 70 7119 2520 +82 70 7119 2510

21, Sangjiseok-gil, Paju-si, Gyeonggi-do, 10911, Korea www.mek-ics.com [email protected]


MTV1000 Offer innovated convenience
Unique technology with high performance
Specification and features subject to change without notice.

MTV1000
Multi Purpose Ventilator
© MEKICS CO.,LTD 2015
MEK-001-CA-MT

Intensive Care System


Intensive Care System
Op
Vo

MTV1000
Fully featured Ventilator
Volum

Multi Purpose, Compact, Portability Pressu

MTV1000 is providing a wide range of respiratory care solution to both hospital and patient.
MTV1000 is used to treat patients with respiratory failure from inadequate ventilation or oxygenation Sync
(or both), as evidenced by hypoxemia with or without hypercapnia.

Ad

Screen displays
MTV1000 provides more useful information
to clinicians. Easy to read and control
allows to help quick access and operating.

Oxygen supply, Oxygen Blending System


MTV1000 has two types of the oxygen supply
which are high and low pressure. O2 Concentration
function is available with O2 Blender.

La
More Clinical Information Jus
MTV1000 provides optional functions Pro
EtCO2, SpO2 and Proximal Pressure Measurement.
More clinical information enables to clinician.

Select the Breathing Circuit.


MTV1000 supply to choose a Dual limb breathing circuit or
Single limb breathing circuit with external exhalation valve.
em
Optimal Ventilation Mode.
Volume Control, Pressure Control, Synchonized and Advanced.

Volume control : This setting means the ventilator is programmed to deliver a preset volume of oxygen and
air, called the tidal volume (VT), regardless of the amount of pressure required to deliver the volume.
Volume Control
Pressure control: Pressure control simply means that pressure is the endpoint rather than volume. Thus,
inspiration ends when a preset pressure is reached, regardless of the volume delivered. The advantage of this
mode is that it allows the volume to change in response to intrathoracic pressure. The goal is to increase mean
airway pressure by prolonging inspiration, ideally recruiting more alveoli than volume control ventilation. By
Pressure Control limiting pressure, there is less risk of pressure-related injury.

Synchronized intermittent mandatory ventilation (SIMV): In this mode, not all spontaneous breaths are
ent. assisted, leaving the patient to draw some breaths on patient. SIMV helps preserve the strength of the respira-
tory musculature, decreases the risk of hyperventilation and barotrauma, and facilitates weaning. Weaning can
tion Synchonized be done by gradually decreasing the percentage of machine-assist ventilation.

Pressure regulated volume control (PRVC): This type of mechanical ventilation is an alternative to strict
pressure control, representing an attempt to obtain the best of both volume and pressure control. PRVC adapts
to changing compliance of the lungs to adjust inspiratory time and pressure to maintain a preset tidal volume.
Advanced

Our New MTV1000


em
“Enables you to provide optimal Respiratory Care.”
ion

Lab Viewer, Easy way to maintain.


Just see the Lab Viewer program when you have maintaining the system without any system disassemble.
Provide more easyful maintain the system.