0% found this document useful (0 votes)
182 views11 pages

Jumo Itron08

JUMO GmbH & Co. KG is a manufacturer of process control instruments with locations in Germany, the UK, and the US. The document describes JUMO's iTRON line of compact microprocessor controllers, which feature a 7-segment display, 3 control keys, self-optimization functions, and configurable inputs and outputs to be used in control applications.

Uploaded by

TariqMaqsood
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
182 views11 pages

Jumo Itron08

JUMO GmbH & Co. KG is a manufacturer of process control instruments with locations in Germany, the UK, and the US. The document describes JUMO's iTRON line of compact microprocessor controllers, which feature a 7-segment display, 3 control keys, self-optimization functions, and configurable inputs and outputs to be used in control applications.

Uploaded by

TariqMaqsood
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 11

JUMO GmbH

JUMO GmbH & & Co.


Co. KG
KG JUMO Instrument
JUMO Instrument Co.
Co. Ltd.
Ltd. JUMO Process
JUMO Process Control,
Control, Inc.
Inc.
Delivery address:
Delivery address: Mackenrodtstraße
Mackenrodtstraße 14
14 JUMO House
JUMO House 6733 Myers
6733 Myers Road
Road
36039 Fulda,
36039 Fulda, Germany
Germany Temple Bank,
Temple Bank, Riverway
Riverway East Syracuse,
East Syracuse, NYNY 13057,
13057, USA
USA
Postal address:
Postal address: 36035
36035 Fulda,
Fulda, Germany
Germany Harlow, Essex
Harlow, Essex CM20
CM20 2DY,
2DY, UK
UK Phone: 315-437-5866
Phone: 315-437-5866
Phone:
Phone: +49 661
+49 661 6003-0
6003-0 Phone: +44
Phone: +44 1279
1279 635533
635533 1-800-554-5866
1-800-554-5866
Fax:
Fax: +49 661
+49 661 6003-607
6003-607 Fax:
Fax: +44 1279
+44 1279 635262
635262 Fax:
Fax: 315-437-5860
315-437-5860
E-mail:
E-mail: [email protected]
[email protected] E-mail: [email protected]
E-mail: [email protected] E-mail: [email protected]
E-mail: [email protected]
Internet:
Internet: www.jumo.net
www.jumo.net Internet: www.jumo.co.uk
Internet: www.jumo.co.uk Internet: www.jumousa.com
Internet: www.jumousa.com

Data Sheet 702040 Page 1/11

JUMO iTRON 04/08/16/32


Compact microprocessor controllers JUMO iTRON 32
Type 702040
Housing for flush-panel mounting to DIN IEC 61554

Brief description
The JUMO iTRON controller series comprises universal and freely programmable com-
pact instruments for a variety of control tasks. It consists of five models, with the bezel JUMO iTRON 16
sizes 96mm x 96mm, 96mm x 48mm in portrait and landscape format, 48mm x 48mm Type 702041
and 48mm x 24mm.
The controllers feature a clearly readable 7-segment display which, depending on the ver-
sion, is 10 or 20 mm high, for process value and setpoint indication or for dialogs. Only
three keys are needed for configuration. Parameter setting is arranged dynamically, and
after two operation-free seconds the value is accepted automatically. Self-optimisation,
which is provided as standard, establishes the optimum controller parameters by a key
stroke. The basic version also includes a ramp function with adjustable gradients. A timer
function has been integrated as an extra.
All controllers can be employed as single-setpoint controllers with a limit comparator, or
as double-setpoint controllers. The linearisations of the usual transducers are stored. Pro-
JUMO iTRON 08
tection is IP66 at the front and IP20 at the back. The electrical connection is by a plug-in Type 702042
connector with screw terminals.
The inputs and outputs are shown in the block structure below.

Block structure JUMO iTRON 08


Type 702043
Process value input Output 1 (K1)
for: Relay (n.o. make)
Resistance thermometer
Pt100, Pt1000, KTY11-6
Thermocouples
Type L, J, U, T, K, N, S, R, B

Current
0 to 20mA, 4 to 20mA Output 2 (K2)
Logic 0/5V or 0/12V
Voltage 0 to 10V, 2 to 10V
for Type 702040/41
702040

optionally configurable JUMO iTRON 04


Logic input as logic input Type 702044
via floating contact
or
for Type 702040/41 with
relay (n.o. make)
(Type 702040/41only)
Features
logic output optionally
k Structured operating
configurable as output 2
and programming layout
Supply k Self-optimisation
AC 48 to 63Hz, 110 to 240V k Ramp function
or Output 3 k Timer function
AC/DC 20 to 30V, 48 to 63Hz (Type 702042/43/44 only)
or k Digital input filter with
DC 10 to 18V Relay (n.o. make)
programmable filter time constant
k 1 limit comparator
k limit switch
Approvals/approval marks (see "Technical data")

2014-09-01/00357838
JUMO GmbH & Co. KG JUMO Instrument Co. Ltd. JUMO Process Control, Inc.
Delivery address: Mackenrodtstraße 14 JUMO House 6733 Myers Road
36039 Fulda, Germany Temple Bank, Riverway East Syracuse, NY 13057, USA
Postal address: 36035 Fulda, Germany Harlow, Essex CM20 2DY, UK Phone: 315-437-5866
Phone: +49 661 6003-0 Phone: +44 1279 635533 1-800-554-5866
Fax: +49 661 6003-607 Fax: +44 1279 635262 Fax: 315-437-5860
E-mail: [email protected] E-mail: [email protected] E-mail: [email protected]
Internet: www.jumo.net Internet: www.jumo.co.uk Internet: www.jumousa.com

Data Sheet 702040 Page 2/11

Technical data
Thermocouple input
Designation Range 1 Measurement Ambient
accuracy temperature error
Fe-Con L -200 to + 900°C ≤0.4% 100 ppm/°C
Fe-Con J EN 60 584 -200 to +1200°C ≤0.4% 100 ppm/°C
Cu-Con U -200 to + 600°C ≤0.4% 100 ppm/°C
Cu-Con T EN 60 584 -200 to + 400°C ≤0.4% 100 ppm/°C
NiCr-Ni K EN 60 584 -200 to +1372°C ≤0.4% 100 ppm/°C
NiCrSi-NiSi N EN 60 584 -100 to +1300°C ≤0.4% 100 ppm/°C
Pt10Rh-Pt S EN 60 584 0— 1768°C ≤0.4% 100 ppm/°C
Pt13Rh-Pt R EN 60 584 0— 1768°C ≤0.4% 100 ppm/°C
Pt30Rh-Pt6Rh B EN 60 584 +300 — 1820 °C ≤0.4% 100 ppm/°C
Cold junction Pt 100 internal
1. These ranges refer to the ambient temperature of 20°C

Resistance thermometer input


Designation Connection type Range Measurement Ambient
accuracy temperature error
Pt 100 EN 60 751 2-/3-wire -200 to +850°C ≤0.1% 50 ppm/°C
Pt 1000 EN 60 751 2-/3-wire -200 to +850°C ≤0.1% 50 ppm/°C
KTY11-6 2-wire -50 to +150°C ≤1.0% 50 ppm/°C
Sensor lead resistance 20Ω max. per lead for 2- and 3-wire circuit
Measurement current 250µA
Lead compensation Not required for 3-wire circuit. For 2-wire circuit, lead compensation can be implemented
in software through process value correction.

Standard signal input


Designation Range Measurement Ambient
accuracy temperature error
Voltage 0 — 10V, input resistance RE > 100kΩ ≤0.1% 100 ppm/°C
2 — 10V, input resistance RE > 100kΩ ≤0.1% 100 ppm/°C
0 — 1V, input resistance RE > 10MΩ1 ≤0.1% 100 ppm/°C
0,2 — 1V, input resistance RE > 10MΩ1 ≤0.1% 100 ppm/°C
Current 4 — 20mA, voltage drop 3V max. ≤0.1% 100 ppm/°C
0 — 20mA, voltage drop 3V max. ≤0.1% 100 ppm/°C
1. for Type 702040/41 with 2 relay outputs (option)

Measurement circuit monitoring1


Transducer Overrange/ Probe /lead short-circuit1 Probe/lead break
underrange
Thermocouple • - •
Resistance thermometer • • •
Voltage 2—10V / 0.2—1V • • •
0—10V/ 0—1V • - -
Current 4—20mA • • •
0—20mA • - -
1. In the event of a fault, the outputs move to a defined status (configurable).

= factory setting • recognised - not recognised

2014-09-01/00357838
JUMO GmbH & Co. KG JUMO Instrument Co. Ltd. JUMO Process Control, Inc.
Delivery address: Mackenrodtstraße 14 JUMO House 6733 Myers Road
36039 Fulda, Germany Temple Bank, Riverway East Syracuse, NY 13057, USA
Postal address: 36035 Fulda, Germany Harlow, Essex CM20 2DY, UK Phone: 315-437-5866
Phone: +49 661 6003-0 Phone: +44 1279 635533 1-800-554-5866
Fax: +49 661 6003-607 Fax: +44 1279 635262 Fax: 315-437-5860
E-mail: [email protected] E-mail: [email protected] E-mail: [email protected]
Internet: www.jumo.net Internet: www.jumo.co.uk Internet: www.jumousa.com

Data Sheet 702040 Page 3/11

Outputs
Assignment Type 702040/41 Type 702042/43/44
Output 1 relay relay
Output 2 logic 0/5V or logic input logic 0/5V
Output 2 (option) logic 0/12V or logic input logic 0/12V
Output 2 (option) relay not possible
Output 3 not available relay
Technical data
Relay n.o. (make) contact
rating 3A at 250VAC resistive load
contact life 150 000 operations at rated load
Logic 0/5V
current limiting 20mA
load resistance Rload 250Ω min.
Logic 0/12V
current limiting 20mA
load resistance Rload 600Ω min.

= factory setting

Controller
Controller type single-setpoint controller with limit comparator, double-setpoint controller
Controller structures P/PD/PI/PID
A/D converter resolution better than 15 bit
Sampling time 210msec/250msec with activated timer function

Timer
Accuracy 0.7% ± 10ppm/°C

Electrical data
Supply (switch-mode power supply) 110 — 240V -15/+10% AC 48 — 63Hz, or 20 — 30V AC/DC 48 — 63Hz, or
10 — 18V DC (Connection to SELV or PELV)
Test voltages (type test) to EN 61 010, Part 1, March 1994,
overvoltage category II, pollution degree 2, for Type 702040/41
overvoltage category III, pollution degree 2, for Type 702042/43/44
Power consumption max. 7VA
Data backup EEPROM
Electrical connection at the rear, via plug-in screw terminals,
conductor cross-section up to 1.5mm2 (1.0mm2 for Type 702040/41) or
2x 1.5mm2 (1.0mm2 for Type 702040/41) with ferrules
Electromagnetic compatibility EN 61 326
interference emission Class B
interference immunity to industrial requirements
Safety regulation to EN 61 010-1

Housing
Installation height maximum 2000 m above sea level
Case type Plastic case for panel mounting acc to. IEC 61554 (indoor use)
Dimensions in mm (for Type) 702040 702041 702042 702043 702044
Bezel size 48 x 24 48 x 48 48 x 96 96 x 48 96 x 96
(portrait) (landscape)
Depth behind panel 100 100 70 70 70
+0.6 +0.3 +0.6 +0.6 +0.6 +0.8 +0.8 +0.6 +0.8
Panel cut-out 45 x 22.2 45 x 45 45 x 92 92 x 45 92 x 92+0.8
Ambient/storage temperature range 0 — 55°C / -40 to +70°C

2014-09-01/00357838
JUMO GmbH & Co. KG JUMO Instrument Co. Ltd. JUMO Process Control, Inc.
Delivery address: Mackenrodtstraße 14 JUMO House 6733 Myers Road
36039 Fulda, Germany Temple Bank, Riverway East Syracuse, NY 13057, USA
Postal address: 36035 Fulda, Germany Harlow, Essex CM20 2DY, UK Phone: 315-437-5866
Phone: +49 661 6003-0 Phone: +44 1279 635533 1-800-554-5866
Fax: +49 661 6003-607 Fax: +44 1279 635262 Fax: 315-437-5860
E-mail: [email protected] E-mail: [email protected] E-mail: [email protected]
Internet: www.jumo.net Internet: www.jumo.co.uk Internet: www.jumousa.com

Data Sheet 702040 Page 4/11

Climatic conditions not exceeding 75% rel. humidity, no condensation


Operating position unrestricted
Protection to EN 60 529,
IP66 at the front, IP20 at the back
Weight 75g approx. 95g approx. 145g approx. 160g approx. 200g approx.

Approvals/approval marks
Approval mark Testing agency Certificate/certification number Inspection basis Valid for
UL Underwriter Laboratories E201387 UL 61010-1 all devices
CSA CSA-Approval 232831 CAN/CSA-C22.2No. 61010.1-04 all devices

Display and controls


(1) Display 7-segment display, 4 places, green
Display alternates when setpoints,
parameters and codes are indicated
and entered.
Character height Type 702040/41/42: 10mm, Type 702043/44: 20mm
Display range/unit -1999 to +9999 digit / ° C/ °F
Decimal places none, one, two
(2) Status indication two LEDs for the outputs 1 and 2, yellow
(3) Keys for operating and programming the instrument. Example: Type 702040
Dynamic modification of settings and parameters via the
i and d keys.
Automatic value acceptance after 2 seconds.

Self-optimisation (SO)
The standard self-optimisation facility produces an automatic adjustment of the controller to the process.
Self-optimisation determines the controller parameters for PI and PID controllers (proportional band, reset time, derivative time), as well
as the cycle time and the filter time constant of the digital input filter.

Ramp function
The ramp function enables a defined
approach of the process value from t0 to
the preset setpoint SP.
The slope is set via a gradient
(°C/min or °C/h) at the parameter level.
On a change of setpoint, it will be active either
as a falling or rising ramp.

2014-09-01/00357838
JUMO GmbH & Co. KG JUMO Instrument Co. Ltd. JUMO Process Control, Inc.
Delivery address: Mackenrodtstraße 14 JUMO House 6733 Myers Road
36039 Fulda, Germany Temple Bank, Riverway East Syracuse, NY 13057, USA
Postal address: 36035 Fulda, Germany Harlow, Essex CM20 2DY, UK Phone: 315-437-5866
Phone: +49 661 6003-0 Phone: +44 1279 635533 1-800-554-5866
Fax: +49 661 6003-607 Fax: +44 1279 635262 Fax: 315-437-5860
E-mail: [email protected] E-mail: [email protected] E-mail: [email protected]
Internet: www.jumo.net Internet: www.jumo.co.uk Internet: www.jumousa.com

Data Sheet 702040 Page 5/11

Limit comparator
Function lk1
Window function: Output is active (On) when the lk1 lk2
process value is within a certain range
(window) about the setpoint.
Function lk2
as lk1, but signal function reversed.
Function lk3
low alarm lk3 lk4
Function: output is inactive, when the process
value is below (setpoint - limit value)
Function lk4
as lk3, but reversed signal function
Function lk5
high alarm lk5 lk6
Function: output is inactive when the process
value is above (setpoint + limit value)
Function lk6
as lk5, but reversed signal function.
Function lk7
Switching point is independent of the controller lk7 lk8
setpoint; only AL determines the switching point.
Function: Output is active when the process
value is above the limit value.
Function lk8
as lk7, but reversed signal function.

Limit switch (extra code)


If the limit comparator function is active, then the switched state will have to be reset by hand.
Precondition: the condition that caused the alarm is no longer present (for lk8: process value < AL). The display shows the alarm status.
The alarm status will be retained after a power failure.

Timer function (extra code)


Using the timer function, the control action can be influenced by means of the adjustable time t i 0 . After the timer has been started by
power ON, by pressing the key or via the logic input, the timer start value t i0 is counted down to 0, either instantly or after the process
value has gone above or below a programmable tolerance limit. When the timer has run down, several events are triggered, such as
control switch-off (output 0%) and setpoint switching. Furthermore, it is possible to implement timer signalling during or after the timer
count, via an output.
The timer function can be used in conjunction with the ramp function and setpoint switching.

Table: Timer functions (using the example of a reversed single-setpoint controller)

Start condition
Function Power ON Keypad/logic input Tolerance limit
Time-limited control
The control action is switched off after
the timer has run down (output 0%)

2014-09-01/00357838
JUMO GmbH & Co. KG JUMO Instrument Co. Ltd. JUMO Process Control, Inc.
Delivery address: Mackenrodtstraße 14 JUMO House 6733 Myers Road
36039 Fulda, Germany Temple Bank, Riverway East Syracuse, NY 13057, USA
Postal address: 36035 Fulda, Germany Harlow, Essex CM20 2DY, UK Phone: 315-437-5866
Phone: +49 661 6003-0 Phone: +44 1279 635533 1-800-554-5866
Fax: +49 661 6003-607 Fax: +44 1279 635262 Fax: 315-437-5860
E-mail: [email protected] E-mail: [email protected] E-mail: [email protected]
Internet: www.jumo.net Internet: www.jumo.co.uk Internet: www.jumousa.com

Data Sheet 702040 Page 6/11

Time-dependent setpoint switching


After the timer has been started, the
process is controlled to setpoint SP2.
After the timer has run down, the
controller automatically switches over
to SP1

Time-delayed control
The control action starts after the timer
has run down.

______

Timer with signalling Signalling after timer Signalling from start to


After the timer has been started, t i 0 is count-down (e.g. C122=3) end of timing
counted down to 0. The control action is
independent of the timer.
With this timer function, too, the end of ______
the timer count-down can also be
signalled via an output.

Tolerance limit
The position of the tolerance limit depends on the controller type:
- Single-setpoint controller (reversed, heating): Tolerance limit is below the setpoint
- Single-setpoint controller (direct, cooling): Tolerance limit is above the setpoint
- Double-setpoint controller: Tolerance limit is below the setpoint
If, during the control process, the process value goes above/below the tolerance limit, then the timer will be stopped for the duration of
the infringement.

Display and operation


The timer value is displayed at the operating level and remains so permanently (no time-out).
Operation is from the keypad, when the timer value is visible in the display, or via the logic input. The operating options comprise start,
stop, continue and cancel timer function, and are shown differently in the display.
The current timer value and the timer start value are accessible and adjustable at any time at a separate timer level.

2014-09-01/00357838
JUMO GmbH & Co. KG JUMO Instrument Co. Ltd. JUMO Process Control, Inc.
Delivery address: Mackenrodtstraße 14 JUMO House 6733 Myers Road
36039 Fulda, Germany Temple Bank, Riverway East Syracuse, NY 13057, USA
Postal address: 36035 Fulda, Germany Harlow, Essex CM20 2DY, UK Phone: 315-437-5866
Phone: +49 661 6003-0 Phone: +44 1279 635533 1-800-554-5866
Fax: +49 661 6003-607 Fax: +44 1279 635262 Fax: 315-437-5860
E-mail: [email protected] E-mail: [email protected] E-mail: [email protected]
Internet: www.jumo.net Internet: www.jumo.co.uk Internet: www.jumousa.com

Data Sheet 702040 Page 7/11

Parameter and configuration


Operating level
Designation Display Factory setting Value range
Setpoint SP/SP1/SP2 0 SPL—SPH
Ramp setpoint SPr 0 SPL—SPH
Timer value/timer start value t i /t i 0 0 0 —999.9h

Parameter level
Designation Display Factory setting Value range
Setpoint 1 SP 1 0 SPL—SPH
Setpoint 2 SP 2 0 SPL—SPH
Limit value for limit comparator AL 0 -1999 to +9999 digit
Proportional band 1 Pb:1 0 0 — 9999 digit
Proportional band 2 Pb:2 0 0 — 9999 digit
Derivative time dt 80sec 0 — 9999 sec
Reset time rt 350sec 0 — 9999 sec
Cycle time 1 CY 1 20.0sec 1.0 — 999.9 sec
Cycle time 2 CY 2 20.0sec 1.0 — 999.9 sec
Contact spacing db 0 0 — 1000 digit
Differential (hysteresis) 1 HYS.1 1 0 — 9999 digit
Differential (hysteresis) 2 HYS.2 1 0 — 9999 digit
Working point Y:0 0% -100 to +100 %
Maximum output Y:1 100% 0 to 100 %
Minimum output Y:2 -100% -100 to +100 %
Filter time constant dF 0.6sec 0.0 — 100.0 sec
Ramp slope rASd 0 0 — 999 digit

Configuration level
Designation Display Factory setting Value range/selection
Transducer C111 Pt100 Pt100, Pt1000, KTY11-6, T, J, U, L, K, S,
R, B, N, 0 (4)—20 mA, 0 (2)—10V
Decimal place/unit C112 none/°C none, one, two/°C, F
Controller type/outputs C113 see table on next page
Limit comparator function C114 no function no function, lk1—8
Ramp function C115 no function no function, °C/min, °C/h
Output signal on overrange/ C116 0% output 0%, 100%, -100%
underrange limit comparator off limit comparator on/off
Logic input C117 no function key / level inhibit,
ramp stop, setpoint switching
Outputs 1, 2 and 3 C118 functions as defined freely configurable
(only Type 702042/43/44) under C113 (see table on next page)
Timer function C120 no function see description “Timer function”
Start condition for timer C121 from keypad/ - power ON
logic input - keypad/logic input
- tolerance limit
Timer signalling C122 no function - timer start to timer run-down
- after run-down for 10sec
- after run-down for 1 min.
- after run-down until acknowledgement
Unit of time (timer) C123 mm.ss - mm.ss
- hh.mm
- hhh.h
Start value of value range SCL 0 -1999 to +9999 digit

2014-09-01/00357838
JUMO GmbH & Co. KG JUMO Instrument Co. Ltd. JUMO Process Control, Inc.
Delivery address: Mackenrodtstraße 14 JUMO House 6733 Myers Road
36039 Fulda, Germany Temple Bank, Riverway East Syracuse, NY 13057, USA
Postal address: 36035 Fulda, Germany Harlow, Essex CM20 2DY, UK Phone: 315-437-5866
Phone: +49 661 6003-0 Phone: +44 1279 635533 1-800-554-5866
Fax: +49 661 6003-607 Fax: +44 1279 635262 Fax: 315-437-5860
E-mail: [email protected] E-mail: [email protected] E-mail: [email protected]
Internet: www.jumo.net Internet: www.jumo.co.uk Internet: www.jumousa.com

Data Sheet 702040 Page 8/11

End value of value range SCH 100 -1999 to +9999 digit


Lower setpoint limit SPL -200 -1999 to +9999 digit
Upper sepoint limit SPH 850 -1999 to +9999 digit
Process value correction OFFS 0 -1999 to +9999 digit
Differential (hysteresis) HySt 1 0—9999 digit

Controller type/outputs (C 113)


Controller type Output 1 Output 2 + 3
Single setpoint reversed controller limit comparator/timer signalling
Single setpoint direct controller limit comparator/timer signalling
Double setpoint controller reversed controller direct
Single setpoint reversed limit comparator/timer signalling controller
Single setpoint direct limit comparator/timer signalling controller
Double setpoint controller direct controller reversed

= factory setting

Expanded configuration options for the outputs on Type 702043/44 (C118)


Output 1: Relay (K1) Output 2: Logic (K2) Output 3: Relay
Functions of the outputs as defined under C 113
1-setpoint controller

controller output limit comparator timer signalling


controller output timer signalling limit comparator
limit comparator controller output timer signalling
limit comparator timer signalling controller output
timer signalling controller output limit comparator
timer signalling limit comparator controller output
controller output 1 controller output 2 limit comparator/timer
2-setpt. controller

controller output 1 limit comparator/timer controller output 2


controller output 2 controller output 1 limit comparator/timer
controller output 2 limit comparator/timer controller output 1
limit comparator/timer controller output 1 controller output 2
limit comparator/timer controller output 2 controller output 1

2014-09-01/00357838
JUMO GmbH & Co. KG JUMO Instrument Co. Ltd. JUMO Process Control, Inc.
Delivery address: Mackenrodtstraße 14 JUMO House 6733 Myers Road
36039 Fulda, Germany Temple Bank, Riverway East Syracuse, NY 13057, USA
Postal address: 36035 Fulda, Germany Harlow, Essex CM20 2DY, UK Phone: 315-437-5866
Phone: +49 661 6003-0 Phone: +44 1279 635533 1-800-554-5866
Fax: +49 661 6003-607 Fax: +44 1279 635262 Fax: 315-437-5860
E-mail: [email protected] E-mail: [email protected] E-mail: [email protected]
Internet: www.jumo.net Internet: www.jumo.co.uk Internet: www.jumousa.com

Data Sheet 702040 Page 9/11

Dimensions
Type 702040 / … Type 702043/...

Type 702041 / … Type 702044/...

Type 702042 / …

Edge-to-edge mounting
(minimum spacings of the panel cut-outs)

Type horizontal vertical


70.2040/41 8mm min. 8mm min.
70.2042/43/44 10mm min. 10mm min.

2014-09-01/00357838
JUMO GmbH & Co. KG JUMO Instrument Co. Ltd. JUMO Process Control, Inc.
Delivery address: Mackenrodtstraße 14 JUMO House 6733 Myers Road
36039 Fulda, Germany Temple Bank, Riverway East Syracuse, NY 13057, USA
Postal address: 36035 Fulda, Germany Harlow, Essex CM20 2DY, UK Phone: 315-437-5866
Phone: +49 661 6003-0 Phone: +44 1279 635533 1-800-554-5866
Fax: +49 661 6003-607 Fax: +44 1279 635262 Fax: 315-437-5860
E-mail: [email protected] E-mail: [email protected] E-mail: [email protected]
Internet: www.jumo.net Internet: www.jumo.co.uk Internet: www.jumousa.com

Data Sheet 702040 Page 10/11

Connection diagrams
JUMO iTRON 32, Type 702040, 48mm x 24mm format
JUMO iTRON 16, Type 702041, 48mm x 48mm format
Standard version / Version with 12V logic output Version with 2 relay outputs

JUMO iTRON 08, Type 702042, 48mm x 96mm format (portrait)


JUMO iTRON 08, Type 702043. 96mm x 48mm format (landscape)
JUMO iTRON 04, Type 702044, 96mm x 96mm format

2014-09-01/00357838
JUMO GmbH & Co. KG JUMO Instrument Co. Ltd. JUMO Process Control, Inc.
Delivery address: Mackenrodtstraße 14 JUMO House 6733 Myers Road
36039 Fulda, Germany Temple Bank, Riverway East Syracuse, NY 13057, USA
Postal address: 36035 Fulda, Germany Harlow, Essex CM20 2DY, UK Phone: 315-437-5866
Phone: +49 661 6003-0 Phone: +44 1279 635533 1-800-554-5866
Fax: +49 661 6003-607 Fax: +44 1279 635262 Fax: 315-437-5860
E-mail: [email protected] E-mail: [email protected] E-mail: [email protected]
Internet: www.jumo.net Internet: www.jumo.co.uk Internet: www.jumousa.com

Data Sheet 702040 Page 11/11

Order details
(1) (2) (3) (4) (5) (6)
Type designation 7020 .. / .. - ... - ... - .. / ... , ...*
* List extra codes in sequence, separated by commas

(1) Basic type 40 = 48 x 24, 41 = 48 x 48, 42 = 48 x 96 (portrait), 43 = 96 x 48 (landscape), 44 = 96 x 96


(bezel size in mm)
(2) Basic type 88 = controller type configurable1
extension 99 = controller type configured to customer specification2
(3) Inputs 888 = inputs configurable1
999 = inputs configured to customer specification2
(4) Outputs 000 = Standard Type 702040/41 Type 702042/43/44
Output 1 relay (n.o. make) relay (n.o. make)
Output 2 logic 0/5V, optionally configurable logic 0/5V
as logic input
Output 3 not available relay (n.o. make)

Options Type 702040/41 Type 702042/43/44


113 = Output 2 logic 0/12V, optionally logic 0/12V
(outputs 1+3 as for Standard) configurable as logic input
101 = Output 2 relay (n.o. make) not possible
(output 1 as for Standard) (logic input is always available)
(5) Supply 16 = 10—18V DC
25 = 20—30V AC/DC 48—63Hz
23 = 110—240V AC -15/+10% 48—63Hz
(6) Extra code 069 = UL and CSA approval
210 = Timer function
220 = Timer function + limit switch3
Delivery package ex-factory for Type 702040/41 Type 702042/43/44
1 mounting frame 2 mounting brackets
1 seal, 1 Operating Instructions 70.2040
1. single-setpoint with limit comparator, see factory settings under configuration and parameter level
2. see extra order codes (below) or factory settings under configuration and parameter level
3. The linearizations for KTY11-6 and thermocouple B have been deleted

Extra order codes for customized configuration


(2) Basic type extension
Controller type Output 1 Output 2 and 3
10 = single setpoint reversed1 controller limit comparator/timer signalling
11 = single setpoint direct2 controller limit comparator/timer signalling
30 = double setpoint controller reversed controller direct
20 = single setpoint reversed1 limit comparator/timer signalling controller
21 = single setpoint direct 2 limit comparator/timer signalling controller
33 = double setpoint controller direct controller reversed
1. controller output is active when process value is below setpoint, e. g. heating
2. controller output is active when process value is above setpoint, e. g. cooling

(3) Inputs
001 = Pt100 3-wire 040 = Fe-Con J 045 = Pt13 Rh-Pt R 063 = 0—10V
003 = Pt100 2-wire 041 = Cu-Con U 046 = Pt30 Rh-PtRh B 071 = 2—10V
005 = Pt1000 2-wire 042 = Fe-Con L 048 = NiCrSi-NiSi N 601 = KTY11-6 (PTC)
006 = Pt1000 3-wire 043 = NiCr-Ni K 052 = 0—20mA
039 = Cu-Con T 044 = Pt10Rh-Pt S 053 = 4—20mA
= factory-set

2014-09-01/00357838

You might also like