CASCADE AERATOR Sample Report
HYDRAULIC DESIGN
OF
WATER TREATMENT PLANT
CAPACITY - 5 MLD
SALT DESIGN & INFRA PVT. LTD. 1/1
CASCADE AERATOR Sample Report
TABLE OF CONTENTS
Hydraulic Design Of Cascade Aerator ...................................................................................................... 5
Inlet Shaft ...................................................................................................................................... 5
Steps And Planner ............................................................................................................................ 6
Collection Launder ........................................................................................................................... 8
SALT DESIGN & INFRA PVT. LTD. /
CASCADE AERATOR Sample Report
HYDRAULIC DESIGN
INLET SHAFT
STEPS AND PLANNER
COLLECTION LAUNDER
SALT DESIGN & INFRA PVT. LTD. 4/9
CASCADE AERATOR Sample Report
HYDRAULIC DESIGN OF CASCADE AERATOR
The role of Aeration is to remove undesirable dissolved gases in water and to add oxygen to water to convert
undesirable substances to a more manageable form.
INLET SHAFT
(Reference Table No. 1)
Number of Units = Nos
Designed Flow Per Unit = 6.25 MLD
Designed Capacity in m3/sec = 0.072 m3 /sec
ASSUMPTIONS & CALCULATIONS:
Assumed velocity of flow through Inlet Shaft = 1.25 m/sec
Diameter of Inlet Shaft Required =
DRequired = 0.272 m
Provide Internal Diameter of Inlet Shaft = 0.275 m
Assumed thickness of Inlet Shaft = 0.2 m
Hence, Outer Diameter = 0.675 m
VALIDATION CHECKS:
1. Provided Diameter 0.275 > Required Diameter = 0.272 m
Diameter Provided > Diameter Required.
2. Velocity Achieved = 1.213 m/s
Hence, Velocity achieved is within the permissible Range (0.6 -1.25m/sec)
DESIGN SUMMARY - INLET SHAFT
Velocity = 1.25 m/sec
Internal Diameter of Inlet Shaft = 0.275 m
Thickness of Inlet Shaft = 0.2 m
Outer Diameter of Inlet Shaft = 0.675 m
SALT DESIGN & INFRA PVT. LTD. 5/9
CASCADE AERATOR Sample Report
STEPS AND PLANNER
(Reference Table No. 1)
Number of Units = 1 Nos
Designed Flow Per Unit = 6.25 MLD
Designed Capacity in m3/sec = 260.417 m3/hr
ASSUMPTIONS & CALCULATIONS:
Assumed criteria for area of Aerator = 0.020 m3/m2/hr
Area of Aerator Required =
AreaRequired = 5.208 m2
Provide Area of Aerator = 3.7 m2
Diameter of Aerator =
Diameter of Aerator = 2.274 m
Assumed Number of steps = 4
Assumed Rise of each step = 0.4 m
Size of Tread =
Size of Tread = 0.200 m
Provide Tread= 0.20 m
Actual Diameter of Aerator =
Actual Diameter of Aerator = 2.275 m
Total Height of Rise =
Total Height of Rise = 1.6 m
VALIDATION CHECKS:
Actual Area Criteria = 0.016 m3/m2/hr
Actual Area Criteria achieved is within the permissible Limit
(0.015 to 0.045 m3/m2/hr)
SALT DESIGN & INFRA PVT. LTD. 6/9
CASCADE AERATOR Sample Report
DESIGN SUMMARY - STEPS & PLANNER
Area Criteria = 0.020 m3/m2/hr
Diameter of Aerator = 2.274 m
Number of Steps = 4m
Tread Size = 0.20
Rise Size = 0.4 m
Total Rise height = 1.6 m
SALT DESIGN & INFRA PVT. LTD. 7/9
CASCADE AERATOR Sample Report
COLLECTION LAUNDER
Number of Units = 1 Nos
Designed Flow Per Unit = 6.25 MLD
3 3
Designed Capacity in m /sec = 0.072 m /sec
ASSUMPTIONS & CALCULATIONS:
Assumed velocity of flow = 0.6 m/sec
Assumed width of collecting Launder = 0.6 m
Assumed Free Board = 0.3 m
Side Water Depth of Collection Launder =
SWDLaunder = 0.201 m
Total Depth of Collection Launder =
Total Depth of Collection Launder = 0.501 m
DESIGN SUMMARY - COLLECTION LAUNDER
Velocity = 0.6 m/sec
Width = 0.6 m
Side water Depth (SWD) = 0.201 m
Free Board = 0.3 m
Total Depth of Launder = 0.501 m
O.D SHAFT = 0.675 m
I
N
NO. OF STEPS = 4 NOS L
E
T TREAD = 0.20 m
S
H
A RISE = 0.4 m
F.B = 0.3 m F
T
COLLECTION I.D SHAFT = 0.275 m COLLECTION
LAUNDER LAUNDER
WIDTH = 0.6 m DIAMETER OF AERATOR = 2.275 m
Figure No. 1 Cascade Aerator Details
*For Schematic purpose only
SALT DESIGN & INFRA PVT. LTD. 8/9
CASCADE AERATOR Sample Report
SALT DESIGN & INFRA PVT. LTD. 9/9