No. 1 CT-Scan 64 Slice SOMATOM Go - All

The document summarizes the specifications of a Siemens Somatom go.All CT scanner. It lists the scanner's main technical specifications, including its maximum number of slices per rotation of 64, gantry aperture of 70 cm, and generator power of 75 kW. It also describes the scanner's features for automated dose reduction and iterative reconstruction to improve image quality while reducing radiation dose.

Uploaded by

Samu Simamesa
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
826 views2 pages

No. 1 CT-Scan 64 Slice SOMATOM Go - All

The document summarizes the specifications of a Siemens Somatom go.All CT scanner. It lists the scanner's main technical specifications, including its maximum number of slices per rotation of 64, gantry aperture of 70 cm, and generator power of 75 kW. It also describes the scanner's features for automated dose reduction and iterative reconstruction to improve image quality while reducing radiation dose.

Uploaded by

Samu Simamesa
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

Specification CT Scan SOMATOM go.

All

No. Equipment Description

1 CT-Scan 64 Slice SOMATOM go.All

Main Unit
Max number slices/rotation : 32/64 Reconstruction slice
_ Gantry Aperture : 70 cm
Gantry tilt: +/- 300
Heat Storage Capacity : 6.0 MHU equivalent 15 MHU with
SAFIRE
Cooling Rate : 780kHU/min
mA Range: 13-625 mA
Field of View : 500 mm
kW Generator: 75 kW (equivalent to 187 kW with SAFIRE)
kV selection : 70-140 kV in 10 kV steps
Focal Spot : 0.8 x 0.8 mm (small) 1.0 x 1.2 mm (large)
Vertical table range in cm: 46-88.5 cm

Features & Benefits

- CARE Dose4D :Automated real-time tube current adjustment


for best diagnostic image quality at lowest possible dose,
independent of
patient size and anatomy
- Fast Planning: Direct, organ-based setting of scan and recon
ranges for a faster and more standardized workflow.
- Scan&GO : advanced tablet app allows to control scans
from wherever you are.
- Check&GO : Intelligent algorithm flags up problems with
coverage or contrast distribution as they occur.
- CARE i-tilt: 3D reconstructions with concurrent protection of
the dose sensitive organs, for data acquired with a non-tilting
gantry
- SAFIRE : iterative reconstruction method to reduce noise
without loss of image quality. SAFIRE enables up to 60% dose
reduction.
- Tin Filter : cuts out lower dose energies to reduce dose and
optimizes contrast between soft tissue and air.

Page 1 of 2
Software & Applications :
Endoscopic view
Table and Bone Removal
Vessel Extension
WHO Measurement
ROI HU Threshold
3D Visualization
Dual energy ROI
Lung Nodules at CT View&Go

Page 2 of 2