Flapper Mechanism, Fluid Isolation 1/8 or Pad Mounting Body Size 22 MM
Flapper Mechanism, Fluid Isolation 1/8 or Pad Mounting Body Size 22 MM
3
2/2
flapper mechanism, fluid isolation 1
3 3/2
2/2 NO Series
1/8 or pad mounting body
2
1
068
size 22 mm 3/2 U
3 1
FEATURES
• Solenoid valves for use with neutral or aggressive liquids and gases in analytical
and medical systems
• Hermetic separation of control mechanism and fluid:
- Prevents particulate contamination caused by friction of moving parts, assuring
maximum purity of fluid
- Ensures reliable operation in applications with highly aggressive fluids
• Reduced heat transfer between control mechanism and fluid
• Good self-draining capability and easy-to-flush internal cavity
• Low internal volume
• Specific flappermechanism: no pump effect, no stick effect
• Possibility to adapt a power-save connector
• Electrical spade-plug or cable-end connection
GENERAL
Differential pressure -0,9 to +10 bar (usable in 0,1 bar abs. vacuum) [1 bar =100 kPa]
Maximum viscosity 20 cSt (mm2/s)
Response time < 10 ms
Internal volume < 0,48 ml (connections not included)
fluids () temperature range (TS) seal materials ()
FFPM (perfluoroelastomer)
liquids or gases
+5°C to + 50°C FPM (fluoroelastomer)
(filtered 50 µm)
EPDM (ethylene-propylene)
OTHER MATERIALS
Internal parts Stainless steel
ELECTRICAL CHARACTERISTICS
Coil insulation class F
Connector Spade plug (cable Ø 6-8 mm) or cable ends (2)
Connector specification DIN 43650, 11 mm, industry standard B
Electrical safety IEC 335 (cable ends: EN 60730)
Electrical enclosure protection Moulded IP65 (EN 60529) 1 3
Standard voltages DC (=) : 12V - 24V -5% / +10%
2/2 NO function
(Other voltages on request)
power ratings operator
inrush holding ambient replacement coil
prefix (4)
temperature type (1)
Availability, design and specifications are subject to change without notice. All rights reserved.
70%
60% ton = 15 min
50%
2) Find maximum duty cycle value in diagram:
40%
30% ED = 60%
20% 3) Calculate de-energising time:
10%
0%
toff = 15 min x (100% / 60% - 1) = 10 min
0 5 10 15 20 25 30 4) Complete cycle time:
Energising Time ton (min) tcycle = ton + toff = 15 min + 10 min = 25 min
01035GB-2014/R01
HOW TO ORDER
electrical connection
S1 = spade terminals with connector
L0 = with cable ends 457 mm
Availability, design and specifications are subject to change without notice. All rights reserved.
Ordering example: R068A317S1E00F1 = 2-way NC (normally closed), orifice size 2 mm, pad-mounting body width 22 mm,
with spade terminals with connector, EPDM seals, 24 V DC
OPTIONS
• Other subbases, contact us
• Power-save connector (2,5 W after 140 ms of operation), catalogue number of 24 V DC version: 88100934,
catalogue number of 12 V DC version: 833-150063
• Impulse manual operator
INSTALLATION
• The solenoid valves can be mounted in any position without affecting operation
• Pad-mounting solenoid valve supplied with seal
• Pipe connections 1/8 have standard thread according to ISO 228/1
01035GB-2013/R01
= 33 =
2/2 NC 1 3 = 44 =
2 4
9 9 2/2 NC
1 2 3
=
2/2 NO
= =
1 3
15
2/2 NO
= 11
1 2 3
3/2 U 1 2 3 3/2 U
1/8 1 3
1 2 3
A 2
B A
B
C
C
J
G J
H 3
H
3
X 2 x 1/8
X
D D
= = = F = = = = F =
E E
TYPE 02
Solenoid with cable ends (L0)
IEC 335 / cable ends, length 0,45 m
IP40
G068A200..214
= 33 = 2 2/2 NC 1 3
= 44 = 4
9 9 2/2 NC
1 2 3
= =
2/2 NO
15
1
=
3
2/2 NO
= 11
1 2 3
1/8 3/2 U 1 3 1 2 3 3/2 U
2 1 2 3
A
Availability, design and specifications are subject to change without notice. All rights reserved.
A
B B
1
C C 1
G
H 3 H
K K 3
X 2 x 1/8
X
D = F =
= D = = F = = =
1 2 wires, length 0,45 m
prefix catalogue
type A B C D E F G H J K X weight (1) 2 4 mounting holes, max. depth 7 mm, for
option number
self-tapping screw (type EJOT PT, K30)
G068A...S1.. 60 28,5 17,5 46,2 62,5 22,3 60,8 67,8 82 - 33 0,130
01 S1 3 Manual operator location
R068A...S1.. 60 28,5 17,5 50 65 22,3 - 61,8 76 - 27 0,124
01035GB-2013/R01
G068A...L0.. 35 28,5 17,5 46,2 - 22,3 60,8 67,8 - 56,5 33 0,124 4 4 mounting holes Ø 3,2 mm (4 hexagon soc-
02 L0
R068A...L0.. 35 28,5 17,5 50 - 22,3 - 61,8 - 50,5 27 0,120 ket head cap mounting screws M3 x 8 mm,
(1)
Type 01: Incl. coil(s) and connector(s). stainless steel, ISO 4762 supplied.)
Type 02: with 0,45 m cable ends
=
2 Max. diameter 4,5 mm (3 x)
= 11 =
25
1 2 3
=
1
9 9
= 44 =
= 55 =
2/2 NC
1 2 3
2/2 NO
1 2 3
3/2 U
1 2 3
Availability, design and specifications are subject to change without notice. All rights reserved.
01035GB-2013/R01