Plain Diffuser LCC/LKP/LCP: Description Dimensions

LCP is a flush-mounted square diffuser with a circular unperforated face plate for installation in ceiling systems. It can be used for both supplying and extracting air and is suitable for horizontal supply of cooled air. Installing an LCP/LKP diffuser in a plenum box type MB can help achieve a stable airflow and allow for individual adjustment. The diffuser is available in various diameters and colors and can be fitted with presence or temperature sensors.

Uploaded by

Lucică 5566
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
162 views9 pages

Plain Diffuser LCC/LKP/LCP: Description Dimensions

LCP is a flush-mounted square diffuser with a circular unperforated face plate for installation in ceiling systems. It can be used for both supplying and extracting air and is suitable for horizontal supply of cooled air. Installing an LCP/LKP diffuser in a plenum box type MB can help achieve a stable airflow and allow for individual adjustment. The diffuser is available in various diameters and colors and can be fitted with presence or temperature sensors.

Uploaded by

Lucică 5566
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 9

lindab | ceilin g diff users

Plain diffuser LCC/LKP/LCP

LKP LCP

Description Dimensions
LCP is a flush-mounted square diffuser with a circular LKP
unperforated face plate for installation in ceiling systems.
Ød
LKP has a square face plate and the same properties as
LCP.
LCP/LKP can be used for both supply and extract air. LCP/

50
LKP is suitable for the horizontal supply of cooled air and 39
has a large dynamic range.
Installing an LCP/LKP diffuser in a plenum box type MB can 595 *
help to achieve a stable airflow to the diffuser as well as * Ceiling system 1, other ceiling systems see Integra over-
realise the potential for individual adjustment. view.
Damper type B is an unique linear cone damper which
allows to use the full operational area (0-100%) and allows LCP
to balance with a high pressure drop over the box with low
Ød
sound generation. Furthermore the construction of the
damper gives an accurate and reliable measurement.
50

Damper type C and E are with rotating blade dampers for


47

respectively supply and extract. Typically used in applica-


tions that don’t require a high balancing pressure in the ple-
595*
num box .
The LCP and LKP can with the plenum box MBBV be used Ød = 315 => LCP has no mounting holes for MB !
in a Pascal system.
LCP and LKP can be ordered with a presence sensor (-P), a Ød m
temperature sensor (-T), or both. The sensors are built into mm kg
the Faceplate. 125 3.2
160 3.2
• Simple and stylish appearance 200 3.3
• Large dynamic range 250 3.4
• Can be used for both supply and extract air 315 3.5
• Can be adapted to most ceiling systems
• Plenum box with several damper options Maintenance
The face plate can be removed to enable cleaning of internal
Order code parts or to gain access to the duct or box. The visible parts
of the diffuser can be wiped with a damp cloth.
Product LCP/LKP aaa bb (-xx)
Type
LCP/LKP
Connection dim.
Ød 125-315 Materials and finish
Sensor type
Grille box: Galvanised steel
No sensor
Face plate LKP: Galvanised steel
(-P) Presence sensor
(-T) Temperature sensor
Face plate LCP: Aluminium
(-P-T) Presence sensor / Temperature sensor Face plate finish: Powder-coated
Ceiling system Standard colours: RAL 9003 and RAL 9010, gloss 30
1 - 14
The diffuser is available in other colours. Please contact
Example: LCP-160-P-T-1 Lindab’s sales department for further information.

We reserve the right to make changes without prior notice 1


2019-05-09
lindab | ceil ing di ffusers

Plain diffuser LCC/LKP/LCP


Accessories

Plenum box MB
LCC + MB
D LxW

B
Ød1

H
Ød2

e C

LKP + MB LCP + MB
D LxW D LxW
B

B
Ød1

Ød1
H

H
Ød2 Ød2

e C e C

LKP + MB LCC/LCP + MB
Ød1 Ød2 B C D e H* L W Ød1 Ød2 B C D e H* L W
mm mm mm mm
100 125 62 245 78 40 198 - 238 310 260 100 125 62 245 78 40 206 - 246 310 260
100 160 62 245 78 40 198 - 238 310 260 100 160 62 245 78 40 206 - 246 310 260
125 125 75 291 78 40 223 - 263 376 310 125 125 75 291 78 40 231 - 271 376 310
125 160 75 291 78 40 223 - 263 376 310 125 160 75 291 78 40 231 - 271 376 310
125 200 75 291 78 40 223 - 263 376 310 125 200 75 291 78 40 231 - 271 376 310
160 160 92 352 78 40 257 - 297 459 380 160 160 92 352 78 40 265 - 305 459 380
160 200 92 352 78 40 257 - 297 459 380 160 200 92 352 78 40 265 - 305 459 380
160 250 92 352 78 40 257 - 297 459 380 160 250 92 352 78 40 265 - 305 459 380
200 200 112 425 78 40 298 - 338 565 460 200 200 112 425 78 40 306 - 346 565 460
200 250 112 425 78 40 298 - 338 565 460 200 250 112 425 78 40 306 - 346 565 460
200 315 112 425 78 40 298 - 338 565 460 200 315 112 425 78 40 306 - 346 565 460
250 250 137 514 118 60 348 - 388 698 540 250 250 137 514 118 60 356 - 396 698 540
250 315 137 514 118 60 348 - 388 698 540 250 315 137 514 118 60 356 - 396 698 540
315 315 170 675 118 60 413 - 453 858 540 315 315 170 675 118 60 421 - 461 858 540

* Using accessory MBZ the H dimension will increase: * Using accessory MBZ the H dimension will increase:
Ød2 = 125 - 200 mm => H +40 mm Ød2 = 125 - 200 mm => H +40 mm
Ød2 = 250 - 315 mm => H +60 mm Ød2 = 250 - 315 mm => H +60 mm

Order code Damper options


Product MB a bbb ccc d
Type
MB
Damper
B = Linear cone damper
C = Blade damper supply
E = Blade damper extract
Duct connection Ød1
Ø100-315
Diffuser dimension Ød2
Ø125-315
LCP/LKP/LCC + MBBV (Pascal)
Function (Only for B damper)
S = Supply air E = Extract
Go to www.LindQST.com to find details about the MBBV
plenum box and the pascal solutions.
Example 1: LCP-200-P-T-1+MBB-160-200-S
Example 2: LCP-160-1+MBC-125-160

2 We reserve the right to make changes without prior notice


2019-05-09
lindab | ceilin g diff users

Plain diffuser LCC/LKP/LCP


Technical data
Following LCC/LCP/LKP+plenum box data are valid for Throw l0.2
MBB-S/-E. Throw l0.2 [m] can be seen in the diagram for isothermal air,
For MBC, MBE and MBBV data, go to www.lindQST.com . at a terminal velocity of 0.2 m/s.
For full configuration of your LCC/LCP/LKP diffuser, go
to the LindQST Airborne configurator. l0.2 [m] LCC/LKP/LCP 125
160 250
200 315
10

Capacity 8
7

Air flow qv [l/s] and [m3/h], total pressure Δpt [Pa], throw l0.2 6
5
[m] and sound power level LWA [dB(A)] can be seen in the
4
diagrams.
3

Frequency-related sound power level 2


The sound power level in the frequency band is defined as
LWA+Kok. Kok values are specified in charts beneath the dia-
l 0.2 [m]
grams on the following pages. 1
qV [l/s]
15 20 30 40 50 60 70 100 150 200 300 500
qV [m3/h]
60 70 100 150 200 300 500 700 1000 1500

LCC/LKP/LCP+MBB-S Δpt ≥ 50 Pa Δpt ≥ 50 Pa


30 dB(A) 35 dB(A) Sound attenuation
Ød1 Ød2 l/s m3/h l/s m3/h Sound attenuation of the diffusers ΔL from duct to room,
100 125 37 133 44 158 including end reflection, see table below.
100 160 39 140 48 173
125 125 48 173 56 202
125 160 56 202 66 238 LCC/LCP/LKP
+ MBB-S/-E Centre frequency Hz
125 200 61 220 73 263
Ød1 Ød2 63 125 250 500 1K 2K 4K 8K
160 160 67 241 85 306
100 125 17 15 10 17 15 18 19 21
160 200 79 284 99 356
100 160 17 16 6 10 18 18 18 21
160 250 95 342 113 407
125 125 17 15 10 17 15 18 19 21
200 200 92 331 117 421
125 160 15 14 10 17 16 17 18 21
200 250 105 378 122 439
125 200 13 12 7 13 13 16 17 18
200 315 118 425 145 522
160 160 17 15 12 21 19 19 21 21
250 250 112 403 132 475
160 200 17 16 10 20 17 17 19 20
250 315 131 472 168 605
160 250 16 14 7 17 15 16 19 20
315 315 144 518 169 608
200 200 13 11 10 17 18 15 19 18
200 250 14 11 8 15 19 15 18 17
200 315 14 9 7 13 18 14 17 17
250 250 15 10 9 17 18 18 19 19
250 315 15 8 9 16 18 16 18 18
315 315 8 10 10 17 18 17 18 24

Balancing
Balancing guide, see the MB installation instruction.

LCP/LKP/LCC + MBBV (Pascal)


Go to www.LindQST.com to find details about the MBBV
plenum box and the pascal solutions.

We reserve the right to make changes without prior notice 3


2019-05-09
lindab | ceil ing di ffusers

Plain diffuser LCC/LKP/LCP


Technical data

LCC/LKP/LCP without box – supply air LCC/LKP/LCP 125 + MBB-S - Supply air

¨ST;0 A= ,##,+0,#0    ǻpt [Pa] LCP-125+MBB-125-125-S


 250
  200
 50
 150
 45
 100
 40

 70
 35
50
  30

  30 25

 20
20

 15
 LWA dB(A)
,7!D" !
 10
Q6 ;LS= qV [l/s]
       15 20 25 30 40 50 60 70 80 100
Q6 ;MH= qV [m3/h]
      60 70 80 100 150 200 300

Hz 63 125 250 500 1K 2K 4K 8K


Kok 13 7 1 -2 -6 -14 -20 -25

ǻpt [Pa] LCP-125+MBB-100-125-S


250
50
200
150 45

40
100
35
70

50 30

25
30
20
20
15
LWA dB(A)
10
qV [l/s]
10 15 20 25 30 40 50 60 70 80 90
qV [m3/h]
40 50 60 70 80 100 150 200 300

Hz 63 125 250 500 1K 2K 4K 8K


Kok 10 4 2 -2 -6 -10 -17 -23

4 We reserve the right to make changes without prior notice


2019-05-09
lindab | ceilin g diff users

Plain diffuser LCC/LKP/LCP


Technical data

LCC/LKP/LCP 160 + MBB-S - Supply air LCC/LKP/LCP 200 + MBB-S - Supply air

ǻpt [Pa] LCP-160+MBB-160-160-S ǻpt [Pa] LCP-200+MBB-200-200-S


250 250
200 200
150 150
50
50
100 45 100
45
40
70 70 40
35
50 50 35
30
30
30 25 30
25
20 20 20 20
15 15
LWA dB(A) LWA dB(A)
10 10
qV [l/s] qV [l/s]
30 40 50 60 70 80 100 120 140 160 50 60 70 80 90 100 150 200 250 300
qV [m3/h] qV [m3/h]
150 200 300 400 500 200 300 400 500 700 1000

Hz 63 125 250 500 1K 2K 4K 8K Hz 63 125 250 500 1K 2K 4K 8K


Kok 13 8 0 -3 -6 -10 -19 -25 Kok 12 8 0 -3 -5 -14 -21 -24

ǻpt [Pa] LCP-160+MBB-125-160-S ǻpt [Pa] LCP-200+MBB-160-200-S


250 250
200 200
50
150 150
45
45
100 100
40
40
70 70
35
35
50 50
30 30

30 25 30 25

20 20 20 20

15 15
LWA dB(A) LWA dB(A)
10 10
qV [l/s] qV [l/s]
20 25 30 40 50 60 70 80 100 120 30 40 50 60 70 80 100 120 140 160
qV [m3/h] qV [m3/h]
80 100 150 200 300 400 150 200 300 400 500

Hz 63 125 250 500 1K 2K 4K 8K Hz 63 125 250 500 1K 2K 4K 8K


Kok 9 8 1 -3 -6 -11 -16 -22 Kok 12 7 -1 -3 -5 -10 -15 -21

ǻpt [Pa] LCP-160+MBB-100-160-S ǻpt [Pa] LCP-200+MBB-125-200-S


250 250
200 200
50
45
150 150
45
40
100 100 40
35
70 70 35
50 30 50
30
25
30 30 25
20
20 20 20

15 15
LWA dB(A) LWA dB(A)
10 10
qV [l/s] qV [l/s]
10 15 20 25 30 40 50 60 70 80 100 20 25 30 40 50 60 70 80 100 120 140
qV [m3/h] qV [m3/h]
40 50 60 70 80 100 150 200 300 80 100 150 200 300 400 500

Hz 63 125 250 500 1K 2K 4K 8K Hz 63 125 250 500 1K 2K 4K 8K


Kok 9 5 0 -1 -7 -10 -16 -21 Kok 6 6 0 -3 -5 -9 -16 -21

We reserve the right to make changes without prior notice 5


2019-05-09
lindab | ceil ing di ffusers

Plain diffuser LCC/LKP/LCP


Technical data

LCC/LKP/LCP 250 + MBB-S - Supply air LCC/LKP/LCP 315 + MBB-S - Supply air

ǻpt [Pa] LCP-250+MBB-250-250-S ǻpt [Pa] LCP-315+MBB-315-315-S


250 250
200 200
150 150
50 50
100 100
45 45
70 70
40 40
50 50
35 35

30 30 30 30

25 25
20 20
15 20 15 20
LWA dB(A) LWA dB(A)
10 10
qV [l/s] qV [l/s]
50 60 70 80 100 120 140 160 180 200 240 280 50 60 70 80 90 100 150 200 250 300 350 400
3
qV [m /h] qV [m3/h]
200 300 400 500 700 1000 200 300 400 500 700 1250

Hz 63 125 250 500 1K 2K 4K 8K Hz 63 125 250 500 1K 2K 4K 8K


Kok 15 6 -1 -1 -5 -15 -23 -29 Kok 12 4 0 -2 -4 -14 -19 -27

ǻpt [Pa] LCP-250+MBB-200-250-S ǻpt [Pa] LCP-315+MBB-250-315-S


250 250
200 200
150 150 50
50

100 45 100 45

70 40 70 40

50 35 50 35

30 30
30 30
25 25

20 20 20 20
15 15
LWA dB(A) LWA dB(A)
10 10
qV [l/s] qV [l/s]
50 60 70 80 100 120 140 160 180 200 240 50 60 70 80 90 100 150 200 250 300 350 400
qV [m3/h] qV [m3/h]
200 300 400 500 700 200 300 400 500 700 1250

Hz 63 125 250 500 1K 2K 4K 8K Hz 63 125 250 500 1K 2K 4K 8K


Kok 13 8 -1 -2 -5 -13 -20 -26 Kok 13 7 0 -2 -6 -10 -17 -23

ǻpt [Pa] LCP-250+MBB-160-250-S ǻpt [Pa] LCP-315+MBB-200-315-S


250 250
200 200
150 150 50
45
45
100 40 100
40
70 35 70
35
50 30 50
30
25
30 30 25
20
20 20 20

15 15
LWA dB(A) LWA dB(A)
10 10
qV [l/s] qV [l/s]
30 40 50 60 70 80 100 120 140 160 180 50 60 70 80 100 120 140 160 180 200 240 280
qV [m3/h] qV [m3/h]
150 200 300 400 500 200 300 400 500 700 1000

Hz 63 125 250 500 1K 2K 4K 8K Hz 63 125 250 500 1K 2K 4K 8K


Kok 13 7 0 -4 -5 -11 -16 -22 Kok 12 10 0 -3 -6 -12 -19 -24

6 We reserve the right to make changes without prior notice


2019-05-09
lindab | ceilin g diff users

Plain diffuser LCC/LKP/LCP


Technical data

LCC/LKP/LCP without box - Extract LCC/LKP/LCP 125 + MBB-E - Extract air

¨pt [Pa] ,##LKP/LCP 125 160 ǻpt [Pa] LCP-125+MBB-125-125-E


250 250 50
200
200 200
250
150 45
315 150
100 40
100
70 50
45 70 35
50
40 50 30
30
35
25
20 30 30
15 25 20
20
10 20
15
7 LWA dB(A)
LWA dB(A)
5 10
qV [l/s] qV [l/s]
40 50 60 70 100 150 200 300 10 15 20 25 30 40 50 60 80 100 120
qV [m3/h] qV [m3/h]
150 200 300 400 500 700 1000 40 50 60 70 80 100 150 200 300 400

Hz 63 125 250 500 1K 2K 4K 8K


Kok 12 4 -1 -1 -6 -12 -16 -22

ǻpt [Pa] LCP-125+MBB-100-125-E


250
50
200
150 45

100 40
70
35
50
30
30
25
20
15 20
LWA dB(A)
10
qV [l/s]
5 10 15 20 25 30 40 50 60 80
qV [m3/h]
20 30 40 50 60 70 80 100 150 200 300

Hz 63 125 250 500 1K 2K 4K 8K


Kok 13 -1 3 -1 -9 -11 -17 -23

We reserve the right to make changes without prior notice 7


2019-05-09
lindab | ceil ing di ffusers

Plain diffuser LCC/LKP/LCP


Technical data

LCC/LKP/LCP 160 + MBB-E - Extract air LCC/LKP/LCP 200 + MBB-E - Extract air

ǻpt [Pa] LCP-160+MBB-160-160-E ǻpt [Pa] LCP-200+MBB-200-200-E


250 250
200 45 200 50

150 150 45
40
100 100 40
35
70 70 35
30
50 50 30
25
25
30 20 30
20
20 20
15 15
LWA dB(A) LWA dB(A)
10 10
qV [l/s] qV [l/s]
10 15 20 25 30 40 50 60 80 100 150 200 20 25 30 40 50 60 80 100 150 200 250
qV [m3/h] qV [m3/h]
40 50 60 70 80 100 150 200 300 400 500 700 80 100 150 200 300 400 500 700

Hz 63 125 250 500 1K 2K 4K 8K Hz 63 125 250 500 1K 2K 4K 8K


Kok 16 4 -1 -2 -5 -10 -16 -21 Kok 15 5 0 -2 -6 -10 -15 -23

ǻpt [Pa] LCP-160+MBB-125-160-E ǻpt [Pa] LCP-200+MBB-160-200-E


250 50 250
50
200 200
150 45 150 45

100 40 100 40

70 35 70 35

50 50 30
30
25
30 25 30
20
20 20
20
15 15
LWA dB(A) LWA dB(A)
10 10
qV [l/s] qV [l/s]
10 15 20 25 30 40 50 60 80 100 120 140 10 15 20 25 30 40 50 60 80 100 150 200
qV [m3/h] qV [m3/h]
40 50 60 70 80 100 150 200 300 400 500 40 50 60 70 80 100 150 200 300 400 500 700

Hz 63 125 250 500 1K 2K 4K 8K Hz 63 125 250 500 1K 2K 4K 8K


Kok 14 5 0 -1 -6 -11 -15 -21 Kok 16 5 -1 -3 -5 -10 -15 -21

ǻpt [Pa] LCP-160+MBB-100-160-E ǻpt [Pa] LCP-200+MBB-125-200-E


250 250
200 50 200 50

150 150
45 45
100 100
40 40
70 70
35 35
50 50
30 30
30 30
25 25
20 20
20 20
15 15
LWA dB(A) LWA dB(A)
10 10
qV [l/s] qV [l/s]
5 10 15 20 25 30 40 50 60 80 10 15 20 25 30 40 50 60 80 100 120 140
3
qV [m /h] qV [m3/h]
20 30 40 50 60 70 80 100 150 200 300 40 50 60 70 80 100 150 200 300 400 500

Hz 63 125 250 500 1K 2K 4K 8K Hz 63 125 250 500 1K 2K 4K 8K


Kok 11 3 2 0 -8 -13 -17 -23 Kok 11 3 -1 -2 -5 -10 -16 -22

8 We reserve the right to make changes without prior notice


2019-05-09
lindab | ceilin g diff users

Plain diffuser LCC/LKP/LCP


Technical data

LCC/LKP/LCP 250 + MBB-E - Extract air LCC/LKP/LCP 315 + MBB-E - Extract air

ǻpt [Pa] LCP-250+MBB-250-250-E ǻpt [Pa] LCP-315+MBB-315-315-E


250 250
200 50 200 50
150 45 150 45

100 40 100 40

35 35
70 70
30
50 30 50
25
25
30 30 20
20
20 20
15 15
LWA dB(A) LWA dB(A)
10 10
qV [l/s] qV [l/s]
20 25 30 40 50 60 80 100 150 200 250 20 25 30 40 50 60 80 100 150 200 250 300
qV [m3/h] qV [m3/h]
80 100 150 200 300 400 500 700 80 100 150 200 300 400 500 700 1000

Hz 63 125 250 500 1K 2K 4K 8K Hz 63 125 250 500 1K 2K 4K 8K


Kok 11 4 1 -2 -5 -11 -17 -25 Kok 12 4 2 -3 -6 -9 -18 -27

ǻpt [Pa] LCP-250+MBB-200-250-E ǻpt [Pa] LCP-315+MBB-250-315-E


250 50 250
200 200 50
45
150 150 45
40
100 100 40
35 35
70 70

50 30 50 30

25 25
30 30
20
20
20 20
15 15
LWA dB(A) LWA dB(A)
10 10
qV [l/s] qV [l/s]
20 25 30 40 50 60 80 100 150 200 250 20 25 30 40 50 60 80 100 150 200 250 300
qV [m3/h] qV [m3/h]
80 100 150 200 300 400 500 700 80 100 150 200 300 400 500 700 1000

Hz 63 125 250 500 1K 2K 4K 8K Hz 63 125 250 500 1K 2K 4K 8K


Kok 14 4 0 -2 -6 -11 -16 -25 Kok 12 5 2 -3 -6 -10 -17 -24

ǻpt [Pa] LCP-250+MBB-160-250-E ǻpt [Pa] LCP-315+MBB-200-315-E


250 50 250
50
200 200
45 45
150 150
40 40
100 100
35 35
70 70

30 30
50 50
25
25
30 30
20
20
20 20
15 15
LWA dB(A) LWA dB(A)
10 10
qV [l/s] qV [l/s]
10 15 20 25 30 40 50 60 80 100 150 200 20 25 30 40 50 60 80 100 150 200 250
3
qV [m /h] qV [m3/h]
40 50 60 70 80 100 150 200 300 400 500 700 80 100 150 200 300 400 500 700

Hz 63 125 250 500 1K 2K 4K 8K Hz 63 125 250 500 1K 2K 4K 8K


Kok 19 6 -1 -4 -5 -12 -18 -26 Kok 14 5 0 -3 -5 -10 -16 -25

We reserve the right to make changes without prior notice 9


2019-05-09

You might also like