Dräger Savina® Sub-Acute Care Ventilation
Dräger Savina® Sub-Acute Care Ventilation
Benefits
The Dräger Savina is an advanced, high-quality ICU ventilator that offers excellent ventilation performance
combined with easy operation. Designed for both adult and paediatric ventilation, the Savina provides advanced
therapy at any acuity level.
An integrated safety concept makes the Savina the natural choice for challenging environments, such as rural
areas, earthquake zones or regions with erratic unreliable power grids. Its internal battery can bridge power
failures of up to an hour, while an optional external battery can extend that range to 5 hours. Because air is
supplied via an internal turbine, the Savina requires no external source of compressed air – perfect for settings
with limited infrastructure or where frequent transports are necessary. Integrated safeguard sensors for minute
volume, airway pressure and 02 concentration ensure enhanced patient safety.
Increased flexibility
The Savina gives you a full range of ventilation modes, both pressure- and volume-oriented, as well as pressure
support, spontaneous breathing and non-invasive ventilation options. Built for adult and paediatric patients of
all acuity levels, the Savina provides modern ventilation therapy for a very wide range of patients, situations and
clinical settings.
The Savina’s AutoFlow® feature brings the benefits of spontaneous breathing to volume-oriented modes.
BIPAP1 combines pressure-oriented ventilation with spontaneous breathing at any time and at any pressure
level. The Savina’s non-invasive ventilation capabilities are further enhanced by highly sensitive triggering and
effective leak management systems. Together, these features can help you reduce ventilation times, promote
the weaning process, avoid reintubation and reduce the rate of pulmonary complications related to intubation.
An intuitive user interface makes learning to use the Dräger Savina easy. Simply select a parameter, change the
parameter and confirm that change. Changes are visually supported on the high-resolution colour display. The
Savina can also display your choice of static, dynamic, graphic or numeric real-time or trend data on an optional
12” colour touch screen.
Dräger Savina® | 03
Related Products
Dräger Carina®
Evita® V300
The Evita® V300 is a scalable and versatile device which offers high
ventilation quality. To meet and master the changing conditions and
challenges of your everyday hospital work you need flexible equipment
with versatile opportunities.
D-43497-2012
Technical Data
Ventilation modes
‒ IPPV (CMV), IPPVAssist (CMVAssist)
‒ SIMV, SIMVASB (SIMV/PS)
‒ CPAP, CPAPASB (CPAP/PS)
‒ BIPAP1), (PCV+) (optional), BIPAP1)ASB (PCV+/PS)
(optional)
Enhancements
‒ NIV – Non Invasive Ventilation with optimized alarm system
and automatic leakagecompensation (optional)
‒ AutoFlow® – Automatic adaptation of the inspiratory flow in
volume orientated ventilation modes (optional)
‒ LPO - Low Pressure Oxygen. Independant oxygen supply,
e.g. with an O2 concentrator (optional)
‒ Graphic screen - Advanced ventilation monitoring
(optional),
‒ Nurse call - Connection for transmitting alarm signals to a
central alarm system (optional)
Patient type Adult, pediatric
Ventilation frequency 2 to 80 bpm
Inspiration time 0.2 to10 s
Tidal volume 0.05 to 2.0 L, BTPS2)
Inspiratory flow 0 to180 L/min
Inspiratory pressure 0 to 99 mbar3) (cmH2O)
PEEP/interm. PEEP 0 to 35 mbar (cmH2O)
Pressure support/ASB 0 to 35 mbar (cmH2O) (relative to PEEP)
Flow acceleration 5 to 200 mbar/s (cmH2O/s)
O2-concentration 21 to100 Vol. %
Trigger sensitivity 1 to15 L/min
Alarms
Airway pressures high / low
Expiratory minute volume high / low
Tidal volume high / low
Apnea-alarm time 15 to 60 sec
Spontaneous breathing frequency high
Inspiratory O2-concentration high / low
Dräger Savina® | 05
Technical Data
Performance data
Maximum flow for pressure assist/ spontaneous breathing 180 L/min
Valve response time T0…90 ≤ 5 ms
Control principle time-cycled, volume-constant, pressure-controlled
Safety valve opening pressure 100 mbar (cmH2O)
Emergency valve automatically enables spontaneous breathing with filtered
ambientair if air and O2 supply should fail.
Automatic gas switch-over function if O2 supply fails
Output for pneumatic medicament nebuliser synchronized with inspiration
Operating data
Main power connection 100 V to 240 V, 50/60 Hz AC, 10 to 36 V DC
Typical power consumption 100 W
Internal battery approx. 60 min (optional extension up to 7 h)
Gas supply
Air Turbine technology
O2 gas supply 3 bar (39 psi) to 10 % up to 6 bar (87 psi)
2)
BTPS – Body Temperature Pressure Saturated. Measured values relating to the conditions of the patient lung, Body temperature 37 °C, steam-saturated gas, ambient pressure.
3)
1 mbar = 100 Pa, AutoFlow®, Trademark by Dräger
06 | Dräger Savina®
90 51 657 | 15-04-5 | Communications & Sales Marketing | PP | LE | Printed in Germany | Chlorine-free – environmentally compatible | Subject to modifications | © 2015 Drägerwerk AG & Co. KGaA
Notes
CORPORATE HEADQUARTERS REGION EUROPE CENTRAL REGION MIDDLE EAST, AFRICA REGION CENTRAL
Drägerwerk AG & Co. KGaA AND EUROPE NORTH Dräger Medical GmbH AND SOUTH AMERICA
Moislinger Allee 53–55 Dräger Medical GmbH Branch Office Dräger Panama Comercial
23558 Lübeck, Germany Moislinger Allee 53-55 P.O. Box 505108 S. de R.L.
www.draeger.com 23558 Lübeck, Germany Dubai, United Arab Emirates Complejo Business Park,
Tel +49 451 882 0 Tel +971 4 4294 600 V tower, 10th floor
Fax +49 451 882 2080 Fax +971 4 4294 699 Panama City
[email protected] [email protected] Tel +507 377 9100
Manufacturer: Fax +507 377 9130
Dräger Medical GmbH REGION EUROPE SOUTH REGION ASIA / PACIFIC [email protected]
Moislinger Allee 53-55 Dräger Médical S.A.S. Draeger Medical
23558 Lübeck, Germany Parc de Haute Technologie South East Asia Pte Ltd.
d'Antony 2 25 International Business Park
25, rue Georges Besse #04-27/29 German Centre
As of August 2015 92182 Antony Cedex, France Singapore 609916, Singapore
Tel +33 1 46 11 56 00 Tel +65 6572 4388
Dräger Medical GmbH changes
Fax +33 1 40 96 97 20 Fax +65 6572 4399
to Drägerwerk AG & Co. KGaA
[email protected] [email protected]