0% found this document useful (0 votes)
135 views2 pages

ADC Compact Plus Digitizer: Optimal Productivity and Ease-Of-Use

Uploaded by

dawadhali
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
135 views2 pages

ADC Compact Plus Digitizer: Optimal Productivity and Ease-Of-Use

Uploaded by

dawadhali
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

PAGE 1

ADC Compact Plus Digitizer


™ ™

Maximizing Throughput
and Staff Productivity as
You Begin the Transition
From Analog to Digital

Optimal Productivity and Ease-of-use Automated CR plate


reading with no
The ADC Compact Plus digitizer accommodates multiple users and manual interaction
features a drop-and-go buffer that eliminates waiting times; all the necessary
user has to do is to deposit cassettes. The ADC Compact Plus digitizer
automatically takes the cassettes from the input buffer, reads the
demographic data from the memory on the cassette, scans the Waiting times are
imaging plate, digitizes the image and returns the cassette to the
virtually eliminated;
output buffer for new exposures.
users simply
deposit cassettes
No Waiting
The input/output buffer system of the ADC Compact Plus digitizer
takes up to ten cassettes at a time. A user can immediately deposit Maintains equity of
current equipment
cassettes and return to the patient. Waiting times at the digitizer are
investment while
eliminated and staff productivity is maximized. charting a path
to digital
Compact Footprint
The ADC Compact Plus digitizer occupies a very small floorspace and Simple operation
allows two users unhindered access, one at the input and one at the and automated
output, resulting in a smooth flow of operations. It is ergonomically cassette handling
designed to ensure an efficient and safe workplace. processes up to 100
plates per hour

High Productivity
The cassette buffers virtually eliminate waiting times for the staff and
bring the average throughput of the system close to maximum: when
cassettes are in the input buffer, the system operates automatically at
maximum speed, without idle times. No-button/no-switch operation
with automated cassette handling makes the ADC Compact Plus
digitizer a highly productive and user-friendly system, with a
throughput of 90–100 plates an hour depending on size.
PAGE 2
for Information Sharing

Specifications Full Data


The ADC Compact Plus digitizer reads
Dimensions: High Resolution: Environmental the imaging plate with 12 bits/pixel
(w× d × h) 14" × 17'' (35 × 43 cm): Conditions:
33" ×45" ×56" (optional) 3480 × 4240 Temperature: 68 – 86°F grayscale resolution. The complete raw
At foot: 33" 14" × 14'' (35 × 35 cm): (20 – 30°C) data set is transmitted to the image
(optional) 3480 × 3480 Humidity: 10 – 80% RH
At buffer: 56" processing computer. Spatial resolution
8" × 17'' (21 × 43 cm) Magnetic fields: max.
Weight: (partial scan of 14" × 17'' 12.60 µT ranges from 6–10 pixels/mm, depending
Approx. 705 lbs. (35 × 43 cm) cassette): Rate of temperature change: on the imaging plate size.
2020 × 4240 0.9°F/min.
Performance: 10" × 12'' (24 × 30 cm):
Throughput: Standard resolution provides readout
2320 × 2920 Environmental Effects:
90 to 100 plates/hour
10" × 12'' (24 × 30 cm): Noise level: max. 65 dB (A) with approximately 2.3 × 2.8K pixel
(depending on size)
mammo implant Heat dissipation: standby matrices. High resolution reading is
Power: 2380 × 2920 350 W maximum 2000 W available with readout at 10 pixels/mm.
50/60 Hz single phase 8" × 10'' (18 × 24 cm):
1720 × 2320 Safety Standards: All plate sizes are delivered with high
240V + 10%, −10%, max. Europe:
fuse 16A 8" × 10'' (18 × 24 cm):
EN 60950: 1997 and EN
resolution readout, except for 35 × 35
mammo implant
230V ± 10%, max fuse 16A
1780 × 2320
60601-1: 1990 + A1: 1993 cm and 35 × 43 cm plates which are
208V + 10%, −10%, max. + A 2: 1995
6" × 12'' (15 × 30 cm): supplied with standard resolution.
fuse 15A (e.g. USA) USA:
1420 × 2920 These plates are also available with
200V + 10%, −10%, max. UL 1950 resp. UL2601
fuse 15A (e.g. Japan) Spatial Resolution: Canada: optional high resolution readout.
Reading sampling frequency: CSA22.2 No.950 resp.
Cassette Buffer Capacity: CSA22.2 No.601.1
10 cassettes of mixed 14" × 17" (35 × 43 cm): No.601.1.2
sizes, both in input and 6 pixels/mm CSA22.2 No.601.1.2 Analog to Digital, Economically
output buffer 14" × 14" (35 × 35 cm):
6 pixels/mm X-ray: ADC Compact Plus cassettes are
Accepted Cassette Sizes: 14" × 17" HR (35 × 43 cm Europe: compatible with conventional X-ray
14" × 17'' (35 × 43 cm) HR): 10 pixels/mm X-ray regulation 1987
tables. The ADC Compact Plus allows
14" × 14'' (35 × 35 cm) (option) USA:
10" × 12'' (24 × 30 cm) 14" × 14" HR (35 × 35 cm DHHS/FDA 21 CFR part conventional X-ray departments to adopt
HR): 10 pixels/mm 1002, subchapter B digital technology without additional
6" × 12'' (15 × 30 cm)
(option)
8" × 10'' (18 × 24 cm) Laser: investments in digital X-ray units.
10" × 12'' (24 × 30 cm):
Europe:
Grayscale Resolution: 10 pixels/mm
EN 60825 – 1:1994 The optimal productivity of the
Data acquisition: 8" × 10'' (18 × 24 cm):
USA:
12 bits/pixel 10 pixels/mm
DHHS/FDA 21 ADC Compact Plus digitizer makes
Output to processor: 6" × 12'' (15 × 30 cm): CFR parts 1040, 10 and it a cost-effective building block for
12 bits/pixel 10 pixels/mm 1040, 11
the transition to a fully digital
Standard Resolution: LCD Display: Approvals:
Machine status and error
X-ray department.
14" × 17'' (35 × 43 cm): TüV, GS, UL, CUL, CE, CSA
2320 × 2826 conditions
14" × 14'' (35 × 35 cm):
2320 × 2320 For the latest information on product
specifications and features, visit our website at:
www.agfa.com/healthcare

Agfa-Gevaert has been approved by Lloyd’s Register Quality Assurance limited to the following Quality Management Agfa Corporation
System Standards: ISO 9001:1994; EN ISO 9001:1994, and ANSI/ASQC Q9001-1994. HealthCare Headquarters
10 South Academy Street, Greenville, SC 29601
The Quality Management System is applicable to the development, production and distribution of Agfa Medical Films.
Tel: 1-864-421-1600 • Fax: 864-421-1622
Agfa-Gevaert has been awarded the Approval of Conformity certificate by Lloyd’s Register Quality Assurance. Canada
It certifies that the Quality Management System for our X-ray films conforms to the requirements of Annex V of the EEC Directive Agfa, Inc.
93/42 and Medical Devices Regulation 1994:3017. 77 Belfield Road, Etobicoke, Ont., M9W 1G6
Tel: 416-240-7315 • Fax: 416-241-5409
Agfa HealthCare has been approved by Lloyd’s Register Quality Assurance limited to the following Quality Management System
Mexico
Standards: ISO 9001:1994; EN ISO 9001:1994, and ANSI/ASQC Q9001-1994.
Agfa de México, S.A. de C.V.
The Quality Management System is applicable to: Selling, Servicing, Distribution, and Design of Marketing of Agfa‘s Product Benjamin Franklin #98, Colonia Escandon, C.P. 11800, México, D.F.
Assortment of Equipment and Sensitive Materials Used in Medical Diagnostic Imaging, Non-Destructive Testing, Microfilm and Tel: +52 (55) 5699 1400 • Telefax: +52 (55) 5699 1403
Motion Picture Applications.
Agfa-Gevaert has been awarded the ISO 9001 certificate by TÜV Zertifizierungsgemeinschaft e.V.
This is applicable to Agfa’s Quality Management System for design, production and servicing of Agfa Medical Equipment.
Agfa and the Agfa-Rhombus are registered trademarks and see more do more and ADC are trademarks of Agfa Corporation
or its affiliates. Products distributed in North America are manufactured for/by Agfa Corporation, 10 South Academy Street,
Greenville, SC 29601. ©Copyright 2003, Agfa Corporation. All rights reserved.
MI-00590 Rev 4/03