0% found this document useful (0 votes)
126 views1 page

MMA2920SDFM MMA2920SDC HTM02 01 HTM2022 Spec Sheet

This document provides a specification for a 10 bar duplex medical air plant that meets UK standards. The plant includes two oil-lubricated screw compressors, vertical and horizontal vessels, duplex filter/dryer assembly, controls and monitoring sensors, and recommended spare parts. Key details are: - Two 22 kW Atlas Copco compressors, one running as duty and one as standby - Vertical and horizontal vessels totaling 1800 liters and meeting BS 5169 standards - Duplex filter/dryer assembly removes particulates, oil, moisture, and odors to meet ISO 8573-1 standards - Monitoring and control sensors ensure proper compressor and dryer operation along with alarms

Uploaded by

umair186
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
126 views1 page

MMA2920SDFM MMA2920SDC HTM02 01 HTM2022 Spec Sheet

This document provides a specification for a 10 bar duplex medical air plant that meets UK standards. The plant includes two oil-lubricated screw compressors, vertical and horizontal vessels, duplex filter/dryer assembly, controls and monitoring sensors, and recommended spare parts. Key details are: - Two 22 kW Atlas Copco compressors, one running as duty and one as standby - Vertical and horizontal vessels totaling 1800 liters and meeting BS 5169 standards - Duplex filter/dryer assembly removes particulates, oil, moisture, and odors to meet ISO 8573-1 standards - Monitoring and control sensors ensure proper compressor and dryer operation along with alarms

Uploaded by

umair186
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

Unit 7, Catherine Street West, Denton, Manchester, M34 3SY

Telephone: 0161-221-1880 Fax: 0161-221-1881


Website: www.mmpl.uk.com Email: [email protected]

PLANT SPECIFICATION FOR 10 BAR DUPLEX MEDICAL AIR PLANT (Compliant to HTM02-01 and HTM2022)

MMA2920SDFM Floor mounted Compressor Length 6650mm x Width 1285mm x Height 2200mm Weight 1800kg.
MMA2920SDC Compact Vessel mounted Compressors Length 5200mm x Width 2000mm x Height 2200mm Weight 1870kg.

COMPRESSORS
2 Atlas Copco oil lubricated screws (22 kW) 1 compressor running as duty with the 2nd compressor as standby.

VESSELS
MMA2920SDFM 2 x Vertical Vessel 800 litres, MMA2920SDC 1 x Vertical Vessel 500 litres + 2 x Horizontal Vessels 500 litres,
each vessel is fitted with a pressure relief valve, a fusible plug, a manual drain, an automatic drain and a pressure gauge. Built to
BS 5169-75-3-E/EN 286.

DUPLEX FILTER/DRYER ASSEMBLY


Comprising; water separation filters, oil mist separation filters, desiccant dryers, carbon odour filters, sterile filters, line pressure
regulators and line pressure relief valves. All filters are fitted with pressure differential indicators.

CONTROLS AND MONITORING


Pressure sensors to monitor the following; each compressor on/off load (producing air), low vessel pressure, duty and standby
compressor control, dryer fault (pressure drop), high and low pressure fault. Monitoring sensors for each compressor; control
circuit failure, motor overload, output air temperature high. Monitoring sensor for dryer, Dewpoint failure (dryers will automatically
change over in the event of either a pressure or Dewpoint failure).

ELECTRICAL REQUIREMENTS AIR QUALITY SPECIFICATION


Each Compressor requires Nett Plant output after dryer losses – 2920 l/m.
3 Phase + Neutral + Earth supply Meets the requirement of the European Pharmacopoeia
Fused at 50 amps Motor Rated. Particulates as per ISO 8573-1 (Class 0)
Start Current –80 amps. Oil Aerosols as per ISO 8573-1 (Class 0)
Run Current –40 amps Atmospheric Dewpoint > -46 °C
Starter type – Star/Delta.
NOISE RATING
ALARM OUTPUTS 69dB(A)
Clean contacts closed in Normal;
1. PLANT FAULT Any compressor fault or dryer pressure fault.
2. PLANT EMERGENCY Either dryers Dewpoint failed or low vessel pressure.
3. RESERVE MANIFOLD BELOW 50% Monitored by input from backup cylinder manifold if fitted.
4. LINE PRESSURE FAULT Either high or low pipeline pressure fault.
5. BMS OUTPUTS Repeat of all conditions 1-4 above.
Individual indicators provided for all faults including output alarms to enable easy fault diagnosis.

RECOMMENDED SPARES PART NUMBER


25 Ltr compressor oil. ASPA1010
1 off Unloader kit. GA22 (Serial No. Required)
2 off air intake filter elements GA22 (Serial No. Required)
1 off compressor pressure relief valve. GA22 (Serial No. Required)
1 off regulator pressure relief valve for 4 Bar Line Pressure PLP1030-5.3
1 off regulator pressure relief valve for 7 Bar Line Pressure PLP1030-9.0
1 off compressor operating /low pressure switch. ASPA1033
1 off compressor high pressure switch. ASPA1032
2 off pre filter elements. FILTN110/E
2 off carbon filter elements. FILTN111/E
2 off sterile filter elements. FILTN112/E
1 off different pressure gauge. FILTN105
1 off filter bowl auto drain. FILTN106
1 off regulator overhaul kit. ASPA1081
1 off 4 pole 230V relay. ELE2052
1 off 230V timer relay. ELE2053
M.M.P. Ltd Manchester TEL; 0161-221-1880