Project: Gateway Mall, Vasai: Load Calculation / Check For Cherry Picker

This document summarizes the load calculations and structural checks performed for a cherry picker that will be used at the Gateway Mall project in Vasai. It was determined that the minimum slab area of 24.43308 square meters is sufficient to support the cherry picker load of 6.5 metric tons. Additionally, the maximum point load of 41.44 kilonewtons applied by the cherry picker supports is below the permissible stress limit of the 250mm thick concrete slab. All structural capacity checks were found to meet requirements based on the relevant Indian code of practice.

Uploaded by

Raman Iyer
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLSX, PDF, TXT or read online on Scribd
50% found this document useful (2 votes)
215 views1 page

Project: Gateway Mall, Vasai: Load Calculation / Check For Cherry Picker

This document summarizes the load calculations and structural checks performed for a cherry picker that will be used at the Gateway Mall project in Vasai. It was determined that the minimum slab area of 24.43308 square meters is sufficient to support the cherry picker load of 6.5 metric tons. Additionally, the maximum point load of 41.44 kilonewtons applied by the cherry picker supports is below the permissible stress limit of the 250mm thick concrete slab. All structural capacity checks were found to meet requirements based on the relevant Indian code of practice.

Uploaded by

Raman Iyer
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLSX, PDF, TXT or read online on Scribd
You are on page 1/ 1

PROJECT : GATEWAY MALL, VASAI

Load calculation / Check for Cherry Picker

Name of the Equipment : Easy Lift, Piattaforme Aeree, Model No. R360

Case 1 - Load Capacity of the slab

Total Load of the Equipment 6500 Kg = 6.5 MT


Plan Area of Operations
Case 1 = 3.944 X 6.195
Area = 24.43308 Sqm.

Case 2 = 5.207 X 5.209


Area = 27.123263 Sqm.

Minimum Area of operations = 24.43308 Sqm.

Live Load Capacity of the slab for above area = 9962.5198777 kgf
= 9.9625198777 MT >> 6.5MT SAFE

Case 2 - Check for point load

Max. point load on the slab at one support = 41.44 kN


= 41440 N

Area of contact for plate = 1X 0.5


= 500,000 Sq.mm

Thickness of the Floor Slab = 250 mm

Effective Punching / Shear stress at section = 0.0518 N/mm2

Permissible stress = .24 * sqrt(Fck)


= 1.314534138 N/mm2 SAFE
>> .05N/mm2

IS:1343 1980,code of practice for Prestressed concrete the


maximum principal tensile stress is given by 0.24 x square root(fck)-
clause 22.4.1 page 46.