Current in Multiple of In: Cutler-Hammer Type FW/HFW Molded-Case Circuit Breakers

This document provides time-current curves for Cutler-Hammer Type FW/HFW molded-case circuit breakers. It shows the relationship between time and current for thermal and magnetic trip circuit breakers rated for voltages from 220/240VAC to 660/690VAC. The curves illustrate the minimum and maximum trip times for currents from 1 to 10 times the breaker's rated current, allowing for coordination of protection devices.

Uploaded by

baskaranjay5502
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
49 views1 page

Current in Multiple of In: Cutler-Hammer Type FW/HFW Molded-Case Circuit Breakers

This document provides time-current curves for Cutler-Hammer Type FW/HFW molded-case circuit breakers. It shows the relationship between time and current for thermal and magnetic trip circuit breakers rated for voltages from 220/240VAC to 660/690VAC. The curves illustrate the minimum and maximum trip times for currents from 1 to 10 times the breaker's rated current, allowing for coordination of protection devices.

Uploaded by

baskaranjay5502
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

Cutler-Hammer Type FW/HFW Molded-Case Circuit Breakers Application Data

Thermal/Magnetic Trip, Fixed Thermal Fixed Magnetic 29-167W


Time-Current Curves for Coordination
Page 11
Rated Operating Voltage 690 VAC Poles: 2, 3 and 4 Notes:
(a) Fixed Inverse-Time Overcurrent Release.
Rated Amperes Interrupting Ratings – 50/60 Hz (b) Fixed Electromagnetic Release.
Instantaneous RMS Symmetrical Amperes (kA), Icu (c) Total Operation Time.
In Pick-up (d) Interrupting Rating determines end of
40 400 Breaker curve.
Type 220/240Vac 380/415Vac 660/690Vac
FWF 65 35 12
HFWF 100 65 14

Current in Multiple of In
10
0
2 3 4 5 6 7 8 9 101 2 3 4 5 6 7 8 9 102 2 3 4 5 6 7 8 9 103
10000 10000

1 HOUR
1 HOUR

5000 5000

2000 2000

1000 1000

500 500

200 (a) 200

100 100

50 50

Max. Trip Time


20 20

10 10
TIME IN SECONDS

TIME IN SECONDS
5 5
Min.
2 Trip 2
Time
1 1

.5 .5
(b)

.2 .2

.1 .1

.05 .05
(c)
(d)
.02 .02

.01 .01

.005 .005

.002 .002

.001 .001
10
0
2 3 4 5 6 7 8 9 101 2 3 4 5 6 7 8 9 102 2 3 4 5 6 7 8 9 103

Current in Multiple of In
Cutler-Hammer Curve No. SC-5554-93
Dwg. 8890C40 Printed in U.S.A. October 1997

You might also like