0% found this document useful (0 votes)
140 views2 pages

DEIE Interface-DEN142111W PDF

Uploaded by

Ousseni Sawadogo
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
140 views2 pages

DEIE Interface-DEN142111W PDF

Uploaded by

Ousseni Sawadogo
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

SMA DEIE interface

SMA DEIE Interface-10

Compatible Industrial design Flexibility Ease of use


• Interface between DEIE and SMA • Industrial grade PLC with various • Integrated analog and digital I/Os • Plug and play for all connected
inverters interfaces • Different connection configuration devices
• Compatible with SMA communi- • Integrated UPS for short time volt- possible • Web-Interface for configuration
cation system (SC-COM, Cluster age interruption • Future extension possible and diagnostics
Controller, Sunny WebBox) • Integrated Data logger stores daily • Remote access for service, diag-
• Compatible with existing substation csv-files nostics and software updates
PLC

SMA DEIE Interface


Communication and control interface for PV-Plants >250 kW
The SMA DEIE interface is a controller used as a gateway between the DEIE and the SMA datalogger devices like SC-COM,
Cluster Controller or Sunny WebBox. It manages the grid disconnection and the reduction of active and reactive power
requested by the DEIE via the digital and analog signals. It can be installed in parallel of an existing controller managing other
functions of the DEIE.
Via the DEIE system, the grid operator ERDF wants to monitor and manage the PV plants via multiple digital and analog
inputs/outputs.
SMA Deie interface

Technical Data SMA DEIE Interface

Inputs / Outputs with DEIE


Digital inputs 6
Digital outputs 9
Analog inputs 2 x 4…20 mA
PLC Plant communication
Plant communication interface RJ45 10/100 Mbit/s Ethernet
Communication protocols
Sunny WebBox / SC-COM SMA Data1 over RPC
Number of supported RPC devices 50

All products and services described and all technical data are subject to change, even for reasons of country-specific deviations, at any time without notice. SMA assumes no liability for typographical and other errors. For the latest information, please visit www.SMA-Solar.com.
SC-COM / SMA Cluster Controller Modbus
Number of supported Modbus devices 100
Remote communication HTTP (webserver), FTP (download csv-files)
Memory
Logging data Internal SDHC card interface (8 GB)
Logging duration 3 months with FIFO
Logging format .csv files
Environmental conditions in operation
Ambient temperature -15°C to + 55°C
Protection rating IP66
Power supply
Supply voltage 230 V

DEIE_Interface-DEN142111   Printed on FSC-certified paper. SMA DEIE Interface is a registered trademark of SMA Solar Technology AG. Bluetooth® is a registered trademark of Bluetooth SIG, Inc...
Max. current 2A
UPS buffering time 50 seconds
UPS technology Capacitor based
General Data
Dimensions (W / H / D) 500 x 700 x 250 mm
Weight approx. 39 kg
Inverter compatibility
String inverters Sunny Mini Central 7000HV-11, Sunny Mini Central 9000/10000/110000 TLRP,
Sunny Tripower 8000/10000/120000/15000/17000 TL
Central inverters Sunny Central HE-11 series ,Sunny Central HE-20 series, Sunny Central CP series
(with WebBox or SCCOM integrated)

Type designation SMA DEIE Interface-10


Related FW-Version 2.14 or newer

www.SMA-Solar.com SMA Solar Technology

You might also like