AS SIMPLE AS PRESSING
the start button
lution starts again
Our supreme experience in Spectral Domain OCT technology allows us to provide you with
the modern OCT that offers remarkable simplicity of operation. The SOCT Copernicus REVO
will expand the daily demands of any modern practice.
OCT made simple as never before
Position the patient and press the START button to acquire examinations of both eyes.
The SOCT Copernicus REVO, using vocal messages, guides the patient through the process increasing comfort and
reducing patient chair time.
New OCT standard - All functionality In One device.
Once again Revo goes beyond the limits of standard OCT. With its new software, our Revo enables a full functionality
from the retina to the cornea. It brings benefits by combining the potential of several devices. With REVO you can
measure, quantify, calculate and track changes from the cornea to the retina over time with just one OCT device.
A perfect fit for every practice
Small system footprint, various operator and patient positions and connection by a single cable allows the installation
of SOCT Copernicus REVO into the smallest of examination room spaces. Revo’s variety of examination and analysis
tools enables it to effortlessly function as a screening or advanced diagnostic device.
High quality of OCT image
The noise reduction technology provides the finest details proven to be important for early disease detection.
3d view
RETINA
A single 3D macula scan performs both Retina and Ganglion cells analysis.
The software automatically recognises 8 retinal layers which assists with a
precise diagnosis and the mapping of any changes in the patient’s condition.
SOCT Copernicus REVO offers all the newest standards
available in Spectral OCT technology.
ANGIOGRAPHY SOCT 2,3
This non-invasive dye free technique allows the visualization
of the microvasculature of the retina. Both blood flow and
structural visualization will give additional information in the
diagnosis of many retinal diseases. Angiography scan allows
assessment of the structural vasculature of the macula,
periphery or the optic disc. Extremely short scanning time
1.6 second in standard resolution or within ~3 seconds in Mosaic mode: 10x6 mm
high resolution.
ANGIOGRAPHY MOSAIC 2,3
The Angiography mosaic delivers high-detailed images
over large field of the retina. Available modes allow to see
predefined region of the retina in a convenient way.
Manual mode allows to scan desired region. Analysis tools
allow to see vascular layers, enface or thickness maps.
Dedicated FAZ, VFA tools allows to quantify and track
changes.
WIDEFIELD
SCAN
12x12 mm Widefield
Central scan is
perfect for fast and
precise screening of
the patient’s retina.
Peripheral scanning
reveals diseases in
far periphery.
Combined view of two examinations of peripheral scan 12mm + 12 mm. Done in external software.
FOLLOW UP Progression Morphology Progression Quantification
Revo’s standard high density scanning
capability and blood vessel structure
recognition enable a precise alignment
of past and current scans
Operator can analyze changes in
morphology, quantified progression maps
and evaluate the progression trends
GLAUCOMA
Comprehensive glaucoma analysis tools for quan-
tification of Nerve Fiber Layer, Ganglion layer Optic
Nerve Head with DDLS allows for precise diagnosis
and the monitoring of glaucoma over time.
Asymmetry Analysis of Ganglion layers between
hemispheres and between eyes allow the identification
and detection of glaucoma in its early stages and in non-
typical patients.
Keratoconus Astigmatysm Normal
TOPOGRAPHY OCT3
T-OCT™ is a pioneering way to provide detailed corneal Curvature
maps by using posterior dedicated OCT. Anterior, Posterior surface
and Corneal Thickness allow to provide the True Net Curvature in-
formation. With Net power, the precise understading of the patient’s
corneal condition comes easily and is free of errors associate with
modelling of posterior surface of the Cornea.
KERATOCONUS SCREENING
Easly detect and classified keratoconus with Keratoconus classifier.
ANTERIOR
For a standard anterior examination, no
additional lens is required. This allows
the examiner to quickly complete the
scanning procedure.
Additional adapter provided with the
device increases range of clinical appli-
cation in Anterior chamber observation.
Angle to Angle scan
BIOMETRY OCT 3
B-OCT® Innovative method of using the posterior OCT device to measure ocular structure along eye axis. OCT
Biometry provides complete set of Biometry parameters: Axial Length AL, Central Cornea Thickness CCT, Anterior
Chamber Depth ACD, Lens Thickness LT.
Single view Result review VISUALLY VERIFY YOUR
MEASUREMENT
All measurement calipers
are shown on all boundaries
of OCT image provided by
REVO. Now, you can visually
verify, identify and if needed
correct which structure of the
eye has been measured.
Choroidal observation
Wide Central scan
Sclera and Anterior Structure
Cornea wide scan
T E C H N I C A L S P E C I F I C AT I O N
Technology Spectral Domain OCT
Light source SLED, wavelength 830 nm
Bandwidth 50 nm half bandwidth
Scanning speed 80 0001 / 27 000 measurements per second
Axial resolution 5 µm in tissue
2.6 µm digital
Transverse resolution 12 µm, typical 18 µm
Overall scan depth 2.4 mm
Minimum pupil size 3 mm
Focus adjustment range -25 D to +25 D
Scan range Posterior 5–12 mm, Angio2,3 3–6 mm, Anterior 3–16 mm
Scan types 3D, Angio2,3, Radial, B-scan, Raster, Cross
Fundus image Live Fundus Reconstruction
Alignment method Fully automatic, Automatic
Retina analysis Retina thickness, Inner Retinal thickness, Outer Retinal thickness,
RNFL+GCL+IPL thickness, GCL+IPL thickness, RNFL thickness, RPE deformation,
IS/OS thickness
Angiography OCT2,3 Superficial Plexus, Deep Plexus, Outer Retina, Choriocapilaries, Choroid,
Depth Coded, Custom, Enface, Thickness; FAZ, VAS, NFA tools
Angiography mosaic Acquistion method: Auto, Manual
Mosaic modes: 10×6 mm, Manual up to 12 images
Glaucoma analysis RNFL, ONH morphology, DDLS, Ganglion analysis as RNFL+GCL+IP and GCL+IPL,
OU and Hemisphere asymmetry
Biometry OCT3 AL, CCT, ACD, LT
Corneal Topography Map3 Axial [Anterior, Posterior], Refractive Power [Kerato, Anterior, Posterior, Total, Anterior, Posterior],
Net, Axial True Net, Equivalent Keratometer, Elevation [Anterior, Posterior], Height
Anterior Pachymetry map, Epithelium map, LASIK Flap assesment, Angle Assessment, AIOP,
AOD 500/750, TISA 500/750
Anterior Wide Scan Angle to Angle view (Adapter required)
Connectivity DICOM Storage SCU, DICOM MWL SCU, CMDL, Networking
Dimensions (W×D×H) 382×549×462 mm
Weight 23 kg
Fixation target OLED display (the target shape and position can be changed),
external fixation arm
Power supply 100–240 V, 50/60 Hz
Power consumption 115–140 VA
1
scanning speed is optional hardware feature and has to be selected when ordering
2
only for SOCT Copernicus REVO with scanning speed 80 000 measurements per second
3
optional software module to purchase
0197
www.optopol.com Local Distributor:
OPTOPOL Technology sp. z o.o.
ul. Żabia 42, 42-400 Zawiercie, Poland
Tel/Fax: +48 32 6709173
[email protected]
ver. SOCT Copernicus REVO 09-2018