PMIC Optimized For Multi-Core High-Performance System

AXP228
Datasheet

Revision 1.1

2013.01.06

© 2012 X-Powers Limited - All Rights Reserved


X-Powers AXP228
Enhanced Single Cell Li-Battery and Power System Management IC

Version history

Version Modify Time Author Description


Revision 1.0 2012.12.12 Initial version
Revision 1.1 2013.01.06

X-Powers cannot assume responsibility for use of any circuitry other than circuitry entirely embodied in an
X-Powers product. No circuit patent licenses, copyrights, or other intellectual property rights are implied.
X-Powers reserves the right to make changes to the specifications and products at any time without notice.

AXP228 Datasheet V1.1 Copyright © 2012 X-Powers Limited. All Rights Reserved PAGE 2/52
X-Powers AXP228
Enhanced Single Cell Li-Battery and Power System Management IC

Catalog
1 Overview .........................................................................................................................................................4

2 Feature ............................................................................................................................................................5

3 Typical Application ........................................................................................................................................2

4 PIN...................................................................................................................................................................3

5 Pin List ............................................................................................................................................................4

6 Block Diagram................................................................................................................................................6

7 Absolute Ratings ............................................................................................................................................7

8 Electrical Characteristics ..............................................................................................................................8

9 Control and Operation ................................................................................................................................13

9.1 Power On/Off & Reset..................................................................................................................................13

9.2 Power Path Management (IPS).....................................................................................................................15

9.3 Adaptive Flash Charger ................................................................................................................................17

9.4 Multi-Power Outputs ....................................................................................................................................20

9.5 Default Voltage/Timing Set ting ...................................................................................................................21

9.6 E-Gauge system ............................................................................................................................................21

9.7 Multi-Function Pin Description ....................................................................................................................22

9.8 Timer.............................................................................................................................................................22

9.9 TWSI and IRQ ..............................................................................................................................................23

10 REGISTER ...................................................................................................................................................25

11 PACKAGE ....................................................................................................................................................48

AXP228 Datasheet V1.1 Copyright © 2012 X-Powers Limited. All Rights Reserved PAGE 3/52
X-Powers AXP228
Enhanced Single Cell Li-Battery and Power System Management IC

1 Overview

Description
AXP228 is a highly integrated PMIC targeting at single cell Li-battery(Li-ion or
Li-polymer)applications that require multi-channel power conversion outputs. It provides an easy
and flexible power management solution for multi-core processors to meet the increasingly
complex and accurate requirements on power control.

AXP228 comes with an adaptive USB3.0-compatible Flash Charger that supports up to 94%
efficiency and 2.2A charge current. It also supports 21 channels power outputs (including 5-CH
DCDC, with efficiency up to 95%). To ensure the security and stability of the power system,
AXP228 provides multiple channels 12-bit ADC for voltage/current/temperature monitor and
integrates protection circuits such as OVP,UVP,OTP,OCP. Moreover, AXP228s features a unique
E-Gauge™ system, making power gauge easy and exact.

In addition, AXP228 embraces a fast interface for the system to dynaically adjust output voltage
and enable work mode switch so that the battery life can be extended to the largest extent.

Besides, AXP228 features an IPS™ (Intelligent Power Select) circuit to transparently select power
path among USB, external adaptor, Li-battery, and system load, making it possible for the system
to work normally when only external input power but no battery is available.

Lastly, AXP228 is available in 8mm x 8mm x0.75mm 68-pin QFN package.

Applications
• Tablet, Smartphone, DVR
• UMPC-like, Student Computer

AXP228 Datasheet V1.1 Copyright © 2012 X-Powers Limited. All Rights Reserved PAGE 4/52
X-Powers AXP228
Enhanced Single Cell Li-Battery and Power System Management IC

2 Feature

Features
• IPS™
- Input voltage range: 2.9V~6.3V (AMR: • LDOs (14-CH)
0.3V~11V) - RTC_VCC: 30mA, always alive
- Configurable IPS™ system - ALDO1/2: low noise LDO,0.7V~3.3V adjustable,
- Adaptive USB/AC adaptor voltage/current 100mV/step, load current up to 300mA
limit (4.4V/900mA/500mA) - ALDO3: low noise LDO,0.7V~3.3V
• Flash Charger adjustable,100mV/step, load current up to 200mA
- Integrated MOSFET charge current up to 2.2A - LDOIO0/LDOIO1: low noise LDO, 0.7V~3.3V
- Battery temperature monitor adjustable, 100mV/step, load current up to100mA
- Fully support USB charge - DLDO1/ ELDO1:0.7~3.3V djustable,100mV/step,
- High charge accuracy, ±0.5% accuracy load current up to 400mA
- Support 4.1V/4.2V/4.22V/4.24V battery - DLDO2/ DLDO3/ ELDO2/ ELDO3: 0.7~3.3V
- Automatic charge control adjustable,100mV/step,load current up to 200mA
- Support LED to indicate charge status - DLDO4: 0.7V~3.3V adjustable,100mV/step,load
- Automatic charge current adjustment based current up to 100mA
on system load - DC5LDO: 0.7V~1.4V adjustable,100mV/step,load
• Buck DC-DC Converters (5-CH) current up to 200mA
- DC-DC1: 1.6V~3.4V adjustable,100mV/step, • Switch(2-CH)
load current up to 1.4A - DC1SW: internal resistance 100mOhm, power
- DC-DC2: 0.6V~1.54V adjustable,20mV/step, sourced from DCDC1
load current up to 2.5A, support VRC (Voltage - CHGLED:100mA sink strength, can be used to
Ramp Control) drive the motor and charging LED
- DC-DC3: 0.6V-1.86V adjustable, 20mV/step, • Host Interface
load current up to 2.5A - P2WI(Push-Pull Two Wire Interface) for host
- DC-DC4: 0.6V-1.54V adjustable, 20mV/step, communication
load current up to 0.6A - Configurable interrupt management
- DC-DC5: 1.0V-2.55V adjustable, 50mV/step, load - Flexible pin function configuration: 2 GPIOs can
current up to 2A be set as IO or LDO, etc
- Integrated timer

AXP228 Datasheet V1.1 Copyright © 2012 X-Powers Limited. All Rights Reserved PAGE 5/52
X-Powers AXP228
Enhanced Single Cell Li-Battery and Power System Management IC

3 Typical Application

AXP228 Datasheet V1.1 Copyright © 2012 X-Powers Limited. All Rights Reserved PAGE 2/52
X-Powers AXP228
Enhanced Single Cell Li-Battery and Power System Management IC

4 PIN

Figure 4-1. AXP228 PIN

AXP228 Datasheet V1.1 Copyright © 2012 X-Powers Limited. All Rights Reserved PAGE 3/52
X-Powers AXP228
Enhanced Single Cell Li-Battery and Power System Management IC

5 Pin List
Num Name Type Condition Description
1 ELDOIN PI ELDO Input source
2 ELDO2 O Output Pin of ELDO2

3 ELDO3 O Output Pin of ELDO3


4 DC5LDO O Output Pin of DC5LDO
5 DCDC5 I DC-DC5 feedback pin
6 PGND5 G NMOS Ground for DCDC5
7,8 LX5 IO Inductor Pin for DCDC5
9 VIN5 PI DCDC5 input source
10 DC5SET I Setting DCDC5 Output Voltage
VBUS to IPSOUT Selection
Input GND: IPSOUT selects VBUS
High: IPSOUT does not select VBUS
11 N_VBUSEN IO
VBUS to IPSOUT Selection
Output IPSOUT selects VBUS : GND
IPSOUT does not select VBUS: High
Power On-Off key input,Internal 100k pull high
12 PWRON I
to APS
13 VIN1 PI DCDC1 Input Source
14 LX1 IO Inductor Pin for DCDC1
15 PGND1 G NMOS GND for DCDC1
16 DLDO3 O Output Pin of DLDO3
17 DLDO2 O Output Pin of DLDO2
18 DLDOIN PI DLDO Input Source
19 DLDO1 O Output Pin of DLDO1
20 DLDO4 O Output Pin of DLDO4
21 DCDC1 I DC-DC1 feedback pin
22 DC1SW O DCDC1 Switch Output Pin
23 VIN2 PI DCDC2 Input Source
24,25 LX2 IO Inductor Pin for DCDC2
26,27 PGND2 G NMOS Ground for DCDC2
28 DCDC2 I DC-DC2 Feedback Pin
29 IRQ/WAKEUP IO IRQ Output or Wakeup
Battery Temperature Sensor Input or an
30 TS I
External ADC Input
REG GPIO1 or Low noise LDO
31 GPIO1/PWREN IO
92H[2:0] PWREN function set by internal program

AXP228 Datasheet V1.1 Copyright © 2012 X-Powers Limited. All Rights Reserved PAGE 4/52
X-Powers AXP228
Enhanced Single Cell Li-Battery and Power System Management IC

Num Name Type Condition Description


memory
32 ALDO1 O Output Pin of ALDO1
33 DLDOIN PI ALDO Input Source
34 ALDO2 O Output Pin of ALDO2
35 VREF O Internal reference voltage
36 ALDO3 O Output pin of ALDO3
REG GPIO0
37 GPIO0 IO
90H[2:0] Low noise LDO
38 DCDC3 I DC-DC3 feedback pin
39 VIN3 PI DCDC3 Input Source
40,41 LX3 IO Inductor Pin for DCDC3
42 PGND2 G NMOS Ground for DCDC2
43 PWROK O Power Good Indication Output
Clock pin for serial interface. Normally, it
44 SCK I
connects a 2.2K resistor to 3.3V I/O power
Data pin for serial interface. Normally, it
45 SDA IO
connects a 2.2K resistor to 3.3V I/O power
46 VCC_RTC O Output Pin of VCC_RTC
47 VINT PO Internal logic power, 1.8V
48 VBUS PI VBUS input
PWM Charger Current Sense Resistance
49 BATSENSE I
Positive Input
PWM Charger Current Sense Resistance
50 LOADSENSE I
Negative Input
51 N_BATDRV O BAT to PS extern PMOS driver
52 CHGLED O charger status indication
53,54 IPSOUT PO System power source
55,56 ACIN PI Adapter input
PWM Charger Current Limit Sense Resistance
57 CHSENSEP I
Positive Input
PWM Charger Current Limit Sense Resistance
58 CHSENSEN I
Negative Input
59 PGND_CHG G NMOS Ground for PWM Charger
60,61 LX_CHG IO Inductor Pin for PWM Charger
62,63 VIN_CHG I Charger Input source
64 VIN4 I DCDC4 input source
65 LX4 IO Inductor Pin for DCDC4
66 PGND4 G NMOS Ground for DCDC4
67 DCDC4 I Feed back to DCDC4
68 ELDO1 O Output Pin of ELDO1
Exposed Pad, need to be connected to system
69 EP G
ground

AXP228 Datasheet V1.1 Copyright © 2012 X-Powers Limited. All Rights Reserved PAGE 5/52
X-Powers AXP228
Enhanced Single Cell Li-Battery and Power System Management IC

6 Block Diagram

VBUS IPSOUT

ACIN

N_VBUSEN

BAT IPS RTC_LDO RTC_LDO


N_BATDRV

BATSENSE
LOADSENSE
Adaptive ALDOIN
CHSENSEN PWM ALDO2
charger ALDO
CHSENSEP ALDO2
ALDO3
CHGLED

LX_CHG DC1SW
DCDC1
LX_CHG DC-DC1 LX1
VIN1
VIN_CHG PGND1

VIN_CHG
DCDC2
LX2
PWRON LX2
DC-DC2
VIN2
N_OE PGND2
PGND2

DCDC3
LX3
IRQ LX3
SCK Serial Interface DC-DC3
VIN3
SDA PGND3
Control Logic

Bat DCDC4
TS Temperature LX4
DC-DC4
Monitor VIN4
PGND4

VREF Reference DC5LDO


VINT Voltage DCDC5
LX5
DC-DC5 LX5
VIN5
Output voltage PGND5
PWROK monitor DC5SET

DLDOIN
DLDO2
GPIO0 DLDO DLDO2
GPIO
GPIO1 DLDO3
DLDO4
Register
ELDOIN
ELDO2
ELDO
12 bit ADC ELDO2
Current Monitor ELDO3
Voltage Monitor
Temperature Monitor

Figure 6-1. Block Diagram

AXP228 Datasheet V1.1 Copyright © 2012 X-Powers Limited. All Rights Reserved PAGE 6/52
X-Powers AXP228
Enhanced Single Cell Li-Battery and Power System Management IC

7 Absolute Maximun Ratings

SYMBOL DESCRIPTION VALUE UNITS


ACIN Input Voltage -0.3 ~ 11 V
VBUS Input Voltage -0.3 ~ 11 V
TJ Operating Temperature Range -40 ~ 130 ℃
Ts Storage Temperature Range -40 ~150 ℃
TLEAD Maximum Soldering Temperature (at leads,10sec) 300 ℃
VESD Maximum ESD stress voltage,Human Body Model >4000 V
PD Internal Power Dissipation 2700 mW
Figure 0-1. Absolute ratings

AXP228 Datasheet V1.1 Copyright © 2012 X-Powers Limited. All Rights Reserved PAGE 7/52
X-Powers AXP228
Enhanced Single Cell Li-Battery and Power System Management IC

8 Electrical Characteristics
VIN =5V, BAT=3.8V, TA= 25℃
SYMBOL DESCRIPTION CONDITIONS MIN TYP MAX UNITS
ACIN
VIN ACIN Input Voltage 3.8 6.3 V
IOUT VOUT Current Available Before 500mV Voltage Drop 3500 mA
Loading BAT
VUVLO ACIN Under Voltage Lockout 3.8 V
VOUT IPS Output Voltage 2.9 5.0 V
RACIN Internal Ideal Resistance PIN to PIN, ACIN to 120 mΩ
IPSOUT
VBUS
VIN VBUS Input Voltage 3.8 6.3 V
IOUT VOUT Current Available Before 1500 900 mA
Loading BAT
VUVLO VBUS Under Voltage Lockout 3.8 V
VOUT IPS Output Voltage 2.9 5.0 V
RVBUS Internal Ideal Resistance PIN to PIN, VBUS to 160 mΩ
IPSOUT
Battery Charger
VTRGT BAT Charge Target Voltage -0.5% 4.2 +0.5% V
ICHRG Charge Current 1200 2200 mA
ITRKL Trickle Charge Current 10% ICHRG
mA
VTRKL Trickle Charge Threshold 3.0 V
Voltage
ΔVRECHG Recharge Battery Threshold Threshold Voltage -100 mV
Voltage Relative to VTARGET
TTIMER1 Charger Safety Timer Trickle Mode 50 Min
Termination Time
TTIMER2 Charger Safety Timer CC Mode 480 Min
Termination Time
IEND End of Charge Indication CV Mode 10% 15% ICHRG
Current Ratio mA
NTC
VTL Cold Temperature Fault Charge 2.112 V
0 3.264
Threshold Voltage Discharge 3.226
VTH Hot Temperature Fault Charge 0.397 V
0 3.264
Threshold Voltage Discharge 0.282
VTE NTC Disable Threshold Falling Threshold 0.2 V

AXP228 Datasheet V1.1 Copyright © 2012 X-Powers Limited. All Rights Reserved PAGE 8/52
X-Powers AXP228
Enhanced Single Cell Li-Battery and Power System Management IC

Voltage Hysteresis

SYMBO DESCRIPTION CONDITIONS MIN TYP MAX UNITS


L
Off Mode Current
IBATOFF OFF Mode Current BAT=3.8V 40 μA
ISUSPEND USB VBUS suspend Mode BAT=3.8V, 86 μA
current VBUS=5V,
N_VBUSEN=1
Logic
VIL Logic Low Input Voltage 0.3 V
VIH Logic High Input Voltage 1.2 V
TWSI
VCC Input Supply Voltage 1.8 3.3 V
ADDRE TWSI Address 0x68
SS
fSCK Clock Operating Frequency 400 1200 kHZ
tf Clock Data Fall Time 2.2Kohm Pull High 60 ns
tr Clock Data Rise Time 2.2Kohm Pull High 100 ns
DCDC
fOSC Oscillator Frequency Default 3 MHz
DCDC1
IVIN1 Input Current PFM Mode 50 μA
IDC1OUT =0
ILIM1 PMOS Switch Current Limit PWM Mode 2200 mA
IDC1OUT Available Output Current PWM Mode 1400 mA
VDC1OUT Output Voltage Default 1.6 3.0 3.4 V
DCDC2
IVIN2 Input Current PFM Mode 50 μA
IDC2OUT =0
ILIM2 PMOS Switch Current Limit PWM Mode 3000 mA
IDC2OUT Available Output Current PWM Mode 2500 mA
VDC2OUT Output Voltage Range 0.6 1.1 1.54 V
DCDC3
IVIN3 Input Current PFM Mode 50 uA
IDC3OUT =0
ILIM3 PMOS Switch Current Limit PWM Mode 3000 mA
IDC3OUT Available Output Current PWM Mode 2500 mA
VDC3OUT Output Voltage Range 0.6 1.1 1.86 V
DCDC4
IVIN3 Input Current PFM Mode 42 uA
IDC3OUT =0

AXP228 Datasheet V1.1 Copyright © 2012 X-Powers Limited. All Rights Reserved PAGE 9/52
X-Powers AXP228
Enhanced Single Cell Li-Battery and Power System Management IC

ILIM3 PMOS Switch Current Limit PWM Mode 1200 mA


IDC3OUT Available Output Current PWM Mode 600 mA
VDC3OUT Output Voltage Range 0.6 1.1 1.54 V
DCDC5
IVIN3 Input Current PFM Mode 45 uA
IDC3OUT =0
ILIM3 PMOS Switch Current Limit PWM Mode 2600 mA
IDC3OUT Available Output Current PWM Mode 2000 mA
VDC3OUT Output Voltage Range 1.0 1.5 2.55 V

SYMBOL DESCRIPTION CONDITIONS MIN TYP MAX UNITS


RTC_VCC
VRTC_VCC Output Voltage IRTC_VCC=1mA -1% 1.2 1% V
IRTC_VCC Output Current 100 mA
ALDO1
VALDO1 Output Voltage I ALDO1=1mA -1% 0.7 1% V
I ALDO1 Output Current 300 mA
IQ Quiescent Current 67 μA
PSRR Power Supply Rejection Ratio I ALDO1=60mA,1KHz TBD dB
eN Output Noise,20-80KHz Vo=3.3V , Io=20mA 31 μVRMS
ALDO2
VALDO2 Output Voltage I ALDO2=1mA -1% 1.8 1% V
I ALDO2 Output Current 300 mA
IQ Quiescent Current 67 μA
PSRR Power Supply Rejection Ratio I ALDO2=10mA,1KHz TBD dB
eN Output Noise,20-80KHz Vo=3.3V , Io=20mA 31 μVRMS
ALDO3
V ALDO3 Output Voltage I ALDO3=1mA -1% 3.0 1% V
I ALDO3 Output Current 200 mA
IQ Quiescent Current 67 μA
PSRR Power Supply Rejection Ratio I ALDO3=10mA,1KHz TBD dB
eN Output Noise,20-80KHz Vo=3.3V, Io=20mA 43 μVRMS
DLDO1
V DLDO1 Output Voltage I DLDO1=1mA -1% 0.7 1% V
I DLDO1 Output Current 400 mA
IQ Quiescent Current 60 μA
PSRR Power Supply Rejection Ratio I DLDO1=10mA,1KHz TBD dB
eN Output Noise,20-80KHz Vo=3.3V, Io=20mA 100 μVRMS
DLDO2
V DLDO2 Output Voltage I DLDO2=1mA -1% 0.7 1% V
I DLDO2 Output Current 200 mA
IQ Quiescent Current 60 μA
PSRR Power Supply Rejection Ratio I DLDO2=10mA,1KHz TBD dB

AXP228 Datasheet V1.1 Copyright © 2012 X-Powers Limited. All Rights Reserved PAGE 10/52
X-Powers AXP228
Enhanced Single Cell Li-Battery and Power System Management IC

eN Output Noise,20-80KHz Vo=3.3V, Io=20mA 100 μVRMS


DLDO3
V DLDO3 Output Voltage I DLDO3=1mA -1% 3.0 1% V
I DLDO3 Output Current 200 mA
IQ Quiescent Current 60 μA
PSRR Power Supply Rejection Ratio I DLDO3=10mA,1KHz TBD dB
eN Output Noise,20-80KHz Vo=3.3V, Io=20mA 100 μVRMS
DLDO4
V DLDO4 Output Voltage I DLDO4=1mA -1% 3.0 1% V
I DLDO4 Output Current 100 mA
IQ Quiescent Current 60 μA
PSRR Power Supply Rejection Ratio I DLDO4=10mA,1KHz TBD dB
eN Output Noise,20-80KHz Vo=3.3V, Io=20mA 100 μVRMS
ELDO1
V ELDO1 Output Voltage I ELDO1=1mA -1% 0.7 1% V
I ELDO1 Output Current 400 mA
IQ Quiescent Current 60 μA
PSRR Power Supply Rejection Ratio I ELDO1=10mA,1KHz TBD dB
eN Output Noise,20-80KHz Vo=3.3V, Io=20mA 100 μVRMS
ELDO2
V ELDO2 Output Voltage I ELDO2=1mA -1% 0.7 1% V
IELDO2 Output Current 200 mA
IQ Quiescent Current 60 μA
PSRR Power Supply Rejection Ratio I ELDO2=10mA,1KHz TBD dB
eN Output Noise,20-80KHz Vo=3.3V, Io=20mA 100 μVRMS
DLDO3
V ELDO3 Output Voltage I ELDO3=1mA -1% 0.7 1% V
I ELDO3 Output Current 200 mA
IQ Quiescent Current 60 μA
PSRR Power Supply Rejection Ratio IELDO3=10mA,1KHz TBD dB
eN Output Noise,20-80KHz Vo=3.3V, Io=20mA 100 μVRMS
DC5LDO
VDC5LDO Output Voltage I DC5LDO=1mA -1% 0.7 1% V
I DC5LDO Output Current 200 mA
IQ Quiescent Current 60 μA
PSRR Power Supply Rejection Ratio IDC5LDO=10mA , TBD dB
1KHz
eN Output Noise,20-80KHz Vo=3.3V, Io=20mA 100 μVRMS
LDOio0
V LDOio0 Output Voltage I LDOio0=1mA -1% 3.3 1% V
I LDOio0 Output Current 100 mA
IQ Quiescent Current 40 μA
PSRR Power Supply Rejection Ratio I LDOio0=10mA,1KHz TBD dB
eN Output Noise,20-80KHz Vo=3.3V, Io=20mA 40 μVRMS

AXP228 Datasheet V1.1 Copyright © 2012 X-Powers Limited. All Rights Reserved PAGE 11/52
X-Powers AXP228
Enhanced Single Cell Li-Battery and Power System Management IC

LDOio1
V LDOio1 Output Voltage I LDOio1=1mA -1% 3.3 1% V
I LDOio1 Output Current 100 mA
IQ Quiescent Current 40 μA
PSRR Power Supply Rejection Ratio I LDOio1=10mA,1KHz TBD dB
eN Output Noise,20-80KHz Vo=3.3V, Io=20mA 40 μVRMS
DC1SW
RDC1SW Internal Ideal Resistance PIN to PIN,DCDC1 156 mΩ
同 DC1SW
IQ Quiescent Current 40 μA
CHGLED
RDC1SW Internal Ideal Resistance Vin =0.3V 2000 mΩ

AXP228 Datasheet V1.1 Copyright © 2012 X-Powers Limited. All Rights Reserved PAGE 12/52
X-Powers AXP228
Enhanced Single Cell Li-Battery and Power System Management IC

9 Control and Operation


Once AXP228 is powered on, SCK/SDA pin of TWSI will be pulled up to IO Power and then Host can adjust and
monitor AXP228 with rich feedback information.

Remarks: “Host” here refers to system processor.


Remarks: “External Power” below includes ACIN and VBUS input.

9.1 Power On/Off & Reset

Power Enable Key (PEK)


The Power Key (PEK) can be connected between PWRON pin and GND of AXP228. AXP228 can automatically
identify the four status (Long-press ,Short-press ,Key Down ,Key Up) and then correspond respectively.

Power on Source
1. ACIN、VBUS Insert
2. PEK

Power On
System power-on is initiated whenever the following conditions occur:
1. If a valid power source has plugged in (ACIN or VBUS>3.8V), AXP228 will be turned on or not by the default
the configure module configuration.

2. Press PEK can power on AXP228.

After power on, DC-DC and LDO will be soft booted in preset timing sequence, and then either Host or PWREN
pin can enable/disable corresponding power.

Power Off
When you push-and-hold PEK longer than IRQLEVEL, HOST can write “1” into“REG32H [7]” to inform AXP228
to shutdown, which can disable all power output except LDO1.

System power-off is initiated whenever the following conditions occur:


1. input voltage is too low( Low-Power Protection)
2. Power output voltage(DCDC) is too low due to overload( Overload Protection)
3. Input voltage is too high( Overvoltage Protection)( See more details in chapter “ Intelligent Power Select”
4. Push PEK longer more than OFFLEVEL( Default 6s), and system will cut off all power output except
LDO1( there is no need for an extra RESET key)

Remarks: With the automatic protection mechanism, AXP228 can protect whole system by preventing
components from damage due to system abnormality.

AXP228 Datasheet V1.1 Copyright © 2012 X-Powers Limited. All Rights Reserved PAGE 13/52
X-Powers AXP228
Enhanced Single Cell Li-Battery and Power System Management IC

Sleep and wakeup


When the running system needs to enter Sleep mode, Maybe one or several power outputs should be disabled or
change to other voltage. Wakeup can be initiated by the following sources:
1.,ACIN/VBUS insert/remove
2,PEK short/long press
3,PEK nedge
4,Low power warning level1/2
5,GPIO[1:0] Posedg or negedge
6,Software wakeup by Set the REG31H[5]
7,IRQ from high go low
These sources will make the PMU wakeup and all power outputs resume to default voltage in default power on
timing sequence.

See control process under sleep and wakeup modes as below:

Write “1” to REG31H[3] to


start the Wakeup and PMU
will save power status Set ting
at that time

Disable corresponding power


or modify the voltage

Sleep and wait to be Wakeup

Wakeup
sources

Restore Power output and


clear IRQ

System Reset and Output Monitoring (PWROK)


The PWROK pin can be used as the reset signal of application system. During AXP228 startup, PWROK outputs
low level, which will then be pulled high to startup the system after output voltage reaches the regulated value.

When application system works normally, AXP228 will be always monitoring the voltage and load status. If
overload or under-voltage occurs, the PWROK will instantly output low level to reset the system and prevent

AXP228 Datasheet V1.1 Copyright © 2012 X-Powers Limited. All Rights Reserved PAGE 14/52
X-Powers AXP228
Enhanced Single Cell Li-Battery and Power System Management IC

malfunction or data errors.

9.2 Power Path Management (IPS)

The input sources of AXP228 include Li- Battery, external power ACIN (such as AC adapter or USB VBUS
input). IPS can select proper power allotting method according to external power and Li- Battery status.
o If only Li- Battery is available, and no external power input, Li- Battery is used for power input;
o If external power is available (VBUS or ACIN), it is preferred in power supply
o If Li- Battery is available, it will “Seamlessly” switch to Li- Battery once external power is removed
o When both VBUS and ACIN are available, ACIN will be applied to supply power in priority, and Li-
Battery will be charged.
o If the current of ACIN path is not enough, VBUS will be enabled to achieve ACIN/VBUS common power
supply
o If the current is still insufficient, charge current will be reduced to zero, and Battery is used for one of
power sources
Therefore, compatibility of the system with external powers of different drive ability can be dramatically
improved, and no special customized adapters are required to be provided on the part of manufacturers.
Please refer to the following diagram.

As shown above, when ACIN provides insufficient load ability, IPSOUT voltage will fall, and BAT will
change from charge status to discharge to supply load current together with ACIN.

Host can set IPS parameters and read the feedback by visiting internal registers in AXP228 via TWSI.

Voltage-Limit/ Current-Limit Mode and Direct Mode


In order not to affect the USB communication, VBUS is always working under VBUS Voltage-Limit mode by

AXP228 Datasheet V1.1 Copyright © 2012 X-Powers Limited. All Rights Reserved PAGE 15/52
X-Powers AXP228
Enhanced Single Cell Li-Battery and Power System Management IC

default. In this mode, AXP228 ensures that VBUS voltage remains above a configurable reference voltage VHOLD
which can meet the USB specification. The default VHOLD is 4.4V, adjustable in Reg30H [5:3] register.

If the system need to limit the current obtained from USB VBUS, a current-limit mode is provided (See REG30H
[1] register), with 900mA/500mA (Reg30H [1:0]) selectable.

If the system just utilizes the USB for power supply rather than communication, or the USB power adapter is
utilized, AXP228 can be Set to “VBUS Direct Mode” by modifying register REG30H[6], and then AXP228 will
give priority to the application power demand. When the drive ability of USB Host is insufficient or system power
consumption is large so that the VBUS voltage is lower than VHOLD, AXP228 will release IRQ to indicate the
weak power supply ability of Host VBUS, which may affect USB communication, and then Host software will
follow up.

AXP228’s Reaction to External Power Supply Plugin


AXP228 can automatically detect the plug-in of external powers and judge whether the power is usable or not. The
result will be set in corresponding registers, and IRQ will be released to inform the Host at the same time.

The following table has listed the status bits and meanings of external power registers.

Register Status Bits Description


REG00H[7] Indicating the presence of external ACIN
REG00H[6] Indicating whether the external ACIN is usable or not
REG00H[5] Indicating the presence of external VBUS
REG00H[4] Indicating whether the external VBUS is usable or not
REG00H[3] Indicating whether the VBUS voltage is above VHOLD when used
REG00H[1] Indicating whether ACIN/VBUS short circuits on PCB or not
REG00H[0] Indicating whether the system is triggered to startup by ACIN/VBUS or not

The status bit of “indicating whether the VBUS voltage is above VHOLD or not when used” enables the Host to judge
when it receives IRQ7 (indicating weak supply ability) whether VBUS is pulled low by system load input or the
external power itself is below VHOLD, which may facilitate Host software to decide either to keep on working in
Voltage-Limit mode or switch to Direct mode.

When to Select VBUS as Input Power


N_VBUSEN and register REG30H[7]: is used to determined when shall VBUS be used as power supply.

REG30_[7] REG8F_[4] N_VBUSEN REG30H[2] 是否选用


0 0 High 0 No
0 0 Low 1 Yes
0 1 High X No
0 1 Low X Yes
1 X X X Yes

AXP228 Datasheet V1.1 Copyright © 2012 X-Powers Limited. All Rights Reserved PAGE 16/52
X-Powers AXP228
Enhanced Single Cell Li-Battery and Power System Management IC

Low-Power Warning and Low-Power Protection (Automatic Power-off)


With AXP228, the value of VWARNING(low-power warning voltage) and VOFF(automatic shutdown voltage) can be
Set . If the Battery level is found to be lower than VWARNING, IRQ20/IRQ21 will be released. If ALDOIN is lower
than VOFF, AXP228 will automatically enter Shutdown Mode, and disable all other outputs except LDO1.

The two VWARNING, namely, LEVEL 1 and LEVEL 2, which can be defined differently in applications. For example,
use LEVEL1 to indicate insufficient power while LEVEL 2 can be used to indicate the oncoming shutdown.

Over-Voltage Protection
If the external power voltage exceeds 6.3V, AXP228 will release IRQ1/4 for indication. If the external power
voltage exceeds 7V, AXP228 will automatically shutdown the system.

9.3 Adaptive Flash Charger

AXP228 integrates a constant current/voltage PWM charger to automatically control the charge cycle, with a
built-in safety clock capable of automatic charge termination without processor intervention. This charger features
automatic charge current scaling in accordance with the system power consumption, as well as Battery detection,
trickle charge and activation. In addition, the built-in temperature detection circuit can automatically stop the
charge current when the temperature is too high or too low.

Adaptive Charge Startup


The default state of the charger is “Enable”. (It can be programmed via registers. Refer to register REG33H.) When
external power is plugged in, AXP228 will automatically start the charge, and send IRQ to Host for indication. At
the same time, CHGLED pin will output low level to drive external LED to indicate the charging state.

Charge Voltage/Current

VTRGT

ICHRG

VTRKL

ITRKL

AXP228 Datasheet V1.1 Copyright © 2012 X-Powers Limited. All Rights Reserved PAGE 17/52
X-Powers AXP228
Enhanced Single Cell Li-Battery and Power System Management IC

Two Symbolic Voltages


VTRGT=charge target voltage. The VTRGT is 4.2V by default, which can be Set by register (Refer to“REG33H[6:5]”) .
At the same time, AXP228 will automatically adjust the charge target voltage when external power voltage is low.

VRCH=automatic recharge voltage. VRCH=VTRGT-0.1V。

Charge Current
The charge current is 450mA or 1200mA by default, which can be Set by REG33H [3:0].

Charge Process
If the Battery voltage is lower than 3.0V, the charger will automatically enter the pre-charge mode, with charge
current be 1/10 of the preset value. If the Battery voltage is still below 3.0V 40 minutes later (adjustable, see
“REG34H”), charger will automatically enter the Battery activate mode. Refer to “ Battery Activate Mode” section
for details.

Once the Battery voltage exceeds 3.0V, the charger enters constant current mode. If the charge current is below
65% of the preset value, the system will release IRQ17 to indicate that “drive ability of external power is
insufficient, as a result, the charge current is lower than the pre-set value, which may lead to longer charge time, so
stronger power is preferred, or the power-consuming functions should be disabled to shorten the charge time.”

When the Battery voltage reaches the VTRGT, the charger will switch from the constant current mode to constant
voltage mode, and the charge current will fall.

When the charge current is lower than 10% or 15% (adjustable, see register “REG33H”) of the preset value, a
charge cycle ends, and AXP228 will release IRQ18 while the CHGLED pin will stop indicating the charging state.
When the Battery voltage is below VRCH again, the automatic charge will restart, and IRQ17 will be released.

In non-precharge mode, if the charge cycle is not ending after 480 minutes (adjustable, refer to register “REG34H”),
the charger will automatically enter the Battery activate mode.

Battery Activate Mode


At the enterring the Battery activate mode from either pre-charge mode or constant current mod (the timer expires),
AXP228 will release IRQ10 in both cases to indicate that the Battery may be damaged.

In Battery activate mode, the charger always inputs relatively low current to batteries. AXP228 will exit activate
mode and release IRQ11 only if the Battery voltage has reached VRCH.

AXP228 will indicate whether the charger is in Battery activate mode or not in register REG01H.

CHGLED
CHGLED pin is used to indicate charge state and warning. There are four states, namely, charging, not charging,
Battery abnormal warning, and external power over-voltage warning. CHGLED is NMOS Open Drain output, so a
LED can be directly driven by a current-limit resistor to show the four states. The following table has displayed its
two operation modes.

AXP228 Datasheet V1.1 Copyright © 2012 X-Powers Limited. All Rights Reserved PAGE 18/52
X-Powers AXP228
Enhanced Single Cell Li-Battery and Power System Management IC

类型 A
Status 表现 注释
正在 Charge 低电平
不在 Charge 高阻
Battery 异常 25% duty 1Hz 跳变 Charge 器进入 Battery 激活模式,
或者 Battery 温度过高、
过低
过压 25% duty 4Hz 跳变 外部 Power 输入 Voltage 过高

类型 B
Status 表现 注释
正在 Charge 25% duty 1Hz 跳变
不在 Charge 高阻
Battery 异 常 及 25% duty 1Hz 跳变 Charge 器进入 Battery 激活模式,或者 Battery 温度过高、
输入过压 过低以及 Output Voltage 过高
无 Battery 低电平 无 Battery 接入

Battery Temperature Detection


AXP228 can connect a temperature-sensitive resistor via the TS pin to monitor the Battery temperature when the
Battery is charging or discharging. The diagram is shown below.

REG39/3DH
Li BAT VTH
BAT
10uF
C2
TS
NTC If be low, suspend
REG38/3CH Charger or
VTL Warning with IRQ
GND

VTE

In the diagram above, VTH/VTL refer to the high temperature threshold and low temperature threshold, which is
programmable via registers REG38H/39H/3CH/3DH respectively. VTE=0.2V. The temperature-sensitive resistor is
suggested to choose the NTC temperature-sensitive resistor, which is 10Kohm and 1% accuracy at 25℃. AXP228
will send constant current via TS pin, and the current can be Set as 20uA、40uA、60uA、and 80uA (See
registerREG84H) to adapt to different NTC resistors. When the current goes through the temperature-sensitive
resistor, a test voltage is generated, which will be measured by ADC, and compared with regulated value to release
corresponding IRQ or suspend the charge.

AXP228 Datasheet V1.1 Copyright © 2012 X-Powers Limited. All Rights Reserved PAGE 19/52
X-Powers AXP228
Enhanced Single Cell Li-Battery and Power System Management IC

If the resistance value of temperature-sensitive resistor is too high or too low, extra resistors can be serial or parallel
connected to expand the detect extent.

If the Battery is free from temperature-sensitive resistor, TS pin can be linked to the ground, and in that case,
AXP228 will automatically disable the Battery temperature monitoring function.

Battery Detection
AXP228 will automatically detect the Battery presence, record the result in registers (refer to REG01H) and release
IRQ8, IRQ9.

The Battery detection can be enabled and disabled by Host. (Refer to register REG32H.)

9.4 Multi-Power Outputs

The following table has listed the multi-power outputs and their functions of AXP228.
Output Path 类型 默认 Voltage 启动步骤 应用举例 最大驱动能力
DCDC1 BUCK 3.3V 1 3.3V I/O 1400 mA
DCDC2 BUCK 1.1V 1 1.1V CPU 2500 mA
DCDC3 BUCK 1.1V 1 1.1VGPU 2500 mA
DCDC4 BUCK 1.1V 1 1.1V Core 600mA
DCDC5 BUCK 1.5/DC5SET 设定 1 1.5V DDR 2000mA
RTC-LDO LDO 3.0V 1 RTC 30 mA
ALDO1 LDO OFF OFF N/A 300 mA
ALDO2 LDO 1.8V 1 N/A 300 mA
ALDO3 LDO 3.0V 1 N/A 200mA
LDOIO0 LDO OFF OFF N/A 100 mA
LDOIO1 LDO OFF OFF N/A 100 mA
DLDO1 LDO OFF OFF N/A 400 mA
DLDO2 LDO OFF OFF N/A 200 mA
DLDO3 LDO OFF OFF N/A 200mA
DLDO4 LDO OFF OFF N/A 200 mA
ELDO1 LDO OFF OFF N/A 400 mA
ELDO2 LDO OFF OFF N/A 200 mA
ELDO3 LDO OFF OFF N/A 200mA
DC5LDO LDO 1.1V 1 N/A 200mA
DC1SW Switch OFF OFF N/A 400mA

AXP228 includes five synchronous step-down DC-DCs, fourteen LDOs, two switches, as well as multiple timing
and controlling configuration. The work frequency of DC-DC is 3MHz by default, which is adjustable via registers.
External small inductors and capacitors can be connected as well. In addition, both DC-DCs can be Set in fixed
PWM mode or auto mode (automatically switchable according to the load). See register REG80H.

AXP228 Datasheet V1.1 Copyright © 2012 X-Powers Limited. All Rights Reserved PAGE 20/52
X-Powers AXP228
Enhanced Single Cell Li-Battery and Power System Management IC

DC-DC1/2/3/4/5
DCDC3 output voltage ranges from0.6 V to 1.86V,and output voltage of DCDC2 is ranged from 0.6-1.54V,which
can be programmed via registers.( refer to “ register REG23H 27H”).

The output capacitor is recommended to use small ESR ceramic capacitors, for example 10uF X7R.The saturation
current of inductors used must 50% higher than the output current.

LDO 1
LDO1 is always on and can be used to supply continuous power for application RTC with 30mA drive ability
30mA.

ALDO1/2/3
Low noise LDO, output current is 300mA/300mA/200mA

LDOio0/LDOio1
Low noise LDO, output current is 100mA

Soft Start
All DC-DCs and LDOs support soft start which can avoid the impact of dramatic current change on the input path
in system boot stage.

All DC-DCs do not require external Schottky diodes and resister divider feedback circuits. If a certain DC-DC is
unnecessary in application, just float the corresponding LX pins.

9.5 Default Voltage/Timing Set ting

The default voltage and power on/off sequence of each power can be Set by AXP228.

Power on Timing includes eight levels, and the interval between each level can be Set as 1、2、4、16 and 32mS.

Default voltage Set ting: each DC-DC/LDO Set ting ranges from the lowest voltage to the highest voltage.

DC3SET PIN is used to Set the default voltage of DC-DC3:


DC3SET DC3SETGND DC3SETto OAPS DC3SET floating
DC-DC3 voltage 1.8V 3.3V/2.5V 1.2V/1.5V

9.6 E-Gauge system

Ordinary Battery monitor is to estimate the Battery energy by measuring the Battery voltage. However, the multiple
12-bit ADCs in AXP228 can measure Battery voltage, as well as Battery current. It also integrates the gauge
algorithm. According to these data, Host can get the remaining percentage Battery energy and other Battery data,
such as the system real-time consumption, remaining Battery energy, Battery charge progress, remaining Battery

AXP228 Datasheet V1.1 Copyright © 2012 X-Powers Limited. All Rights Reserved PAGE 21/52
X-Powers AXP228
Enhanced Single Cell Li-Battery and Power System Management IC

using time and charge time, etc.

The Enable state controlling and sampling rate of each ADC can be Set via register 84H. The sampling results will
be saved in corresponding registers, register REG00H[2] is used to indicate the Battery charge/discharge current
directions.
Channel 000H STEP FFFH
Battery Voltage 0mV 1.1mV 4.5045V
Bat discharge current 0mA 1mA 4.095A
Bat charge current 0mA 1mA 4.095A
Internal temperature -267.7℃ 0.1℃ 165.8℃
TS pin input 0mV 0.8mV 3.276V

9.7 Multi-Function Pin Description

GPIO[1:0]
Can be defined as GPIO[1:0], or LDO, etc. Please refer to REG90H-92H Instruction for details

CHGLED
Features charge state indication, over-temperature/over-voltage warning, and GPO. Please refer to REG32H
Instruction section for details.

9.8 Timer

AXP228 features a 7-bit internal timer, whose values can be programmed via register REG8AH[6:0]. The
minimum time step of timer is one minute, and the timing range is 1~127 minutes.

AXP228 Datasheet V1.1 Copyright © 2012 X-Powers Limited. All Rights Reserved PAGE 22/52
X-Powers AXP228
Enhanced Single Cell Li-Battery and Power System Management IC

9.9 TWSI and IRQ

SCK … … … …

SDA A6 … A0 R/W ACK R7 … R0 ACK A6 … A0 R/W ACK D7 … D0 ACK

0 0 0 1 0 1
Register Slave
Start Slave Adress Slave Adress Master Drives
pA Adress pA S pA Drives
hA0 hA1 ACK and Stop
hCMD the Data
hNA P

Read Repeated Start, can be replaced by a


STOP and START

SCK … … …

SDA A6 A5 A4 … A0 R/W ACK R7 R6 R5 … R0 ACK D7 D6 … D0 ACK

0 0 0 0
Register Host Sends
Start Slave Adress
pA Adress pA Data pA P
hA0
hCMD hDATA

Write

Figure9-1: Single Read and Write

SCK … … … … …

R/ R/
SDA A6 … A0 W
ACK R7 … R0 ACK A6 … A0 W
ACK D7 … D0 ACK D7 … D0 ACK
0 0 0 1 0 0 1
Register Slave Slave P
Start Slave Adress Slave Adress Master
pA Adress pA S pA Drives Drives
hA0 hA1 ACK hNA
hCMD the Data the Data
hA

Repeated Start Read

SCK … … … … …

A
SDA A5 … A0 R/ AC R
R6 … R0 AC D
D6
AC
… D0 K
R
R6 … R0 AC D
D6
AC
… D0 K
6 W K 7 K 7 7 K 7
0 0 0 0 0 0
Register Host Sends Register Host Sends P
Start Slave Adress
pA Adress pA Data pA Adress pA Data pA
hA0
hCMD hDATA hCMD hDATA
Write

Figure 9-2. Multi Read and Write

Host can communication with AXP228 registers via the TWSI interface, and the operation timing is listed above.
Standard 100KHz or 400KHz frequency is supported, and the highest rate can reach 1.2MHz. In addition, multi
read and write operation is supported, and the device addresses are 69H (READ) and 68H (WRITE).

AXP228 Datasheet V1.1 Copyright © 2012 X-Powers Limited. All Rights Reserved PAGE 23/52
X-Powers AXP228
Enhanced Single Cell Li-Battery and Power System Management IC

When certain events occur, AXP228 will inform Host by pulling down to the IRQ interrupt mechanism, and the
interrupt state will be reserved in interrupt state registers (See registers REG48H, REG49H, REG4AH, REG4BH
and REG4CH). The interrupt can be cleared by writing 1 to corresponding state register bit. When there is no
interrupt, IRQ output will be pulled high (51K resistance higher through the external). Each interrupt can be
masked via interrupt control registers (Refer to registers REG40H, REG41H, REG42H, REG43H, and REG44H).

Bit IRQ DESCRIPTION Bit IRQ DESCRIPTION


REG48_[7] IRQ1 ACIN over voltage REG4B_[7]
REG48_ [6] IRQ2 ACIN insert REG4B_ [6]
REG48_ [5] IRQ3 ACIN remove REG4B_ [5]
Reserved
REG48_ [4] IRQ4 VBUS over voltage REG4B_ [4]
REG48_ [3] IRQ5 VBUS insert REG4B_ [3]
REG48_ [2] IRQ6 VBUS remove REG4B_ [2]
REG48_ [1] IRQ7 VBUS lower than REG4B_ [1] IRQ20 Battery low level
VHOLD warning1
REG48_ [0] reversed REG4B_ [0] IRQ21 Battery low level
warning2
REG49_[7] IRQ8 Battery present REG4C_[7] IRQ22 Timer timeout
REG49_ [6] IRQ9 Battery remove REG4C_ [6] IRQ23 PEK posedge
REG49_ [5] IRQ10 Battery active REG4C_ [5] IRQ24 PEK negedge
mode
REG49_ [4] IRQ11 Exit Battery active REG4C_ [4] Reserved
mode
REG49_ [3] IRQ12 Charging REG4C_ [3]
REG49_ [2] IRQ13 Charge finish REG4C_ [2]
REG49_ [1] IRQ14 Battery over REG4C_ [1] IRQ25 GPIO1 edge trigger
temperature
REG49_ [0] IRQ15 Battery under REG4C_ [0] IRQ26 GPIO0 edge trigger
temperature
REG4A_ [7] IRQ16 IC over temperature
REG4A_ [6] IRQ17 Charge current not
enough
REG4A_ [5] Reserved
REG4A_ [4]
REG4A_ [3]
REG4A_ [2]
REG4A_ [1] IRQ18 PEK short press
REG4A_ [0] IRQ19 PEK long press

AXP228 Datasheet V1.1 Copyright © 2012 X-Powers Limited. All Rights Reserved PAGE 24/52
X-Powers AXP228
Enhanced Single Cell Li-Battery and Power System Management IC

10 REGISTER
Control Register List
Address Description R/W Default
00 Status REG R
01 Mode and charge status REG R
04-0F Data bugger REG R/W 00H
10 DCDC1/2/3/4/5&ALDO1/2&DC5LDO Control REG R/W BFH
12 ELDO1/2/3&DLDO1/2/3/4&DC1SW Control REG R/W 00H
13 ADLDO1/2/3 woke mode REG R/W 81H
15 DLDO1 Voltage Set REG R/W 00H
16 DLDO2 Voltage Set REG R/W 00H
17 DLDO3 Voltage Set REG R/W 00H
18 DLDO4 Voltage Set REG R/W 00H
19 ELDO1 Voltage Set REG R/W 00H
1A ELDO2 Voltage Set REG R/W 00H
1B ELDO3 Voltage Set REG R/W 00H
1C DC5LDO Voltage Set REG R/W 04H
21 DC-DC1 Voltage Set REG R/W 11H
22 DC-DC2 Voltage Set REG R/W 19H
23 DC-DC3 Voltage Set REG R/W 19H
24 DC-DC4 Voltage Set REG R/W 19H
25 DC-DC5 Voltage Set REG R/W 0AH
27 DC-DC2/3 Ramp control REG R/W 00H
28 ALDO1 Voltage Set REG R/W 00H
29 ALDO2 Voltage Set REG R/W 0BH
2A ALDO3 Voltage Set REG R/W 17H
30 VBUS-IPSOUT Path control REG R/W 60H
31 Sleep/wakeup and power off control REG R/W 03H
32 Power off and Battery detection REG R/W 43H
33 Charge control REG1 R/W C6H
34 Charge control REG2 R/W 45H
35 Charge control REG3 R/W 0EH
36 PEK parameter Set REG R/W 5DH
37 DCDC converter work frequency REG R/W 08H
38 Battery under temperature Set REG when charging R/W A5H
39 Battery over temperature Set REG when charging R/W 1FH
3C Battery under temperature Set REG when R/W FCH
discharging
3D Battery over temperature Set REG when R/W 16H

AXP228 Datasheet V1.1 Copyright © 2012 X-Powers Limited. All Rights Reserved PAGE 25/52
X-Powers AXP228
Enhanced Single Cell Li-Battery and Power System Management IC

Address Description R/W Default


discharging
80 DCDC work mode Set REG R/W E0H
82 ADC Enable Set REG1 R/W E0H
84 ADC Sample rate, TS pin Control REG R/W 32H
85 TS ADC sample rate Set REG R/W 00H
8A Timer Set REG R/W 00H
8C/8D PWREN Set REG R/W 00H
8F Over temperature operation Set REG R/W 01H

GPIO Set Register List


Address Description R/W Default
90 GPIO0 Set REG R/W 07H
91 GPIO0 LDO mode output voltage Set REG R/W 1FH
92 GPIO1 control REG R/W 07H
93 GPIO1 LDO mode output voltage Set REG R/W 1FH
94 GPIO[1:0] signal REG R/W 00H
97 GPIO[1:0] pull down Set REG R/W 00H

Interrupt Register List


Address Description R/W Default
40 IRQ enable Set REG1 R/W D8H
41 IRQ enable Set REG2 R/W FFH
42 IRQ enable Set REG3 R/W 03H
43 IRQ enable Set REG4 R/W 03H
44 IRQ enable Set REG5 R/W 00H
48 IRQ status REG1 R/W 00H
49 IRQ status REG2 R/W 00H
4A IRQ status REG3 R/W 00H
4B IRQ status REG4 R/W 00H
4C IRQ status REG5 R/W 00H

ADC Data Register List


Address Description R/W
56 AXP228 internal temperature monitor ADC Data highest 8 bit R
57 AXP228 internal temperature monitor ADC Data lowest 4 bit R
58 TS ADC Data highest 8 bit, Battery temperature R
59 TS ADC Data lowest 4 bit, Battery temperature R
78 Battery voltage highest 8 bit R

AXP228 Datasheet V1.1 Copyright © 2012 X-Powers Limited. All Rights Reserved PAGE 26/52
X-Powers AXP228
Enhanced Single Cell Li-Battery and Power System Management IC

79 Battery voltage lowest 4 bit R


7A Charge current highest 8 bit R
7B Charge current lowest 5 bit R
7C Discharge current highest 8 bit R
7D Discharge current lowest 5 bit R

Address Description R/W Default


B8 Coulomb counter control REG R/W 00H
B9 Gauge result (%) R 64H
E0 Battery full capacity bit[14:8] R/W 00H
E1 Battery full capacity bit[7:0] R/W 00H
E6 Battery low level warning Set REG R/W A0H
Note: Battery full capacity unit :1.456mAH

Register Description

REG 00H: Power Input Status

Bit Description R/W


7 ACIN presence indication R
0:ACIN not exist;1:ACIN exists
6 Indicating whether ACIN is usable R
5 VBUS presence indication R
0:VBUS not exist;1:VBUS exists
4 Indicating whether VBUS is usable R
3 Indicating whether the VBUS voltage is above VHOLD before used. R
2 Indicating the Battery current direction R
0: the Battery is discharging;1: the Battery is charging
1 Indicating whether ACIN and VBUS input short circuit on PCB R
0 Indicating whether the boot source is ACIN or VBUS R
0: Boot source isn’t ACIN/VBUS; 1: Boot source is ACIN/VBUS.

REG 01H: Power Working Mode and Charge Status Indication

Bit Description R/W


7 Indicating whether AXP202 is over-temperature R
0: not over-temperature; 1: over-temperature
6 Charge indication R
0:not charge or charge finished; 1: in charging
5 Battery existence indication R
0:no Battery connected to AXP202; 1: Battery already connected to AXP202

AXP228 Datasheet V1.1 Copyright © 2012 X-Powers Limited. All Rights Reserved PAGE 27/52
X-Powers AXP228
Enhanced Single Cell Li-Battery and Power System Management IC

4 Reserved and unchangeable R


3 Indicating whether the Battery enters the activate mode R
0: not enter the activate mode; 1: already entered the activate mode
2-0 Reserved and unchangeable R

REG 04-0FH: Data Buffer

Note: As long as one of the external powers, batteries or backup batteries exists, this data will be
reserved and free from the startup and shutdown influence.

REG 10H: DCDC1/2/3/4/5&ALDO1/2&DC5LDO Enable Set

Default: XXH
Bit Description R/W Default
7 ALDO2 Enable Set 0:Off; 1:On RW X
6 ALDO1 Enable Set RW X
5 DC-DC5 Enable Set RW X
4 DC-DC4 Enable Set RW X
3 DC-DC3 Enable Set RW X
2 DC-DC2 Enable Set RW X
1 DC-DC1 Enable Set RW X
0 DC5LDO Enable Set RW X
Note:X means that decided by the internal memory Set

REG 12H: Power Output Control

Default: XXH
Bit Description R/W Default
7 DC1SW Enable Set 0:Off; 1:On RW 0
6 DLDO4 Enable Set RW 0
5 DLDO3 Enable Set RW 0
4 DLDO2 Enable Set RW 0
3 DLDO1 Enable Set RW X
2 ELDO3 Enable Set RW 0
1 ELDO2 Enable Set RW 0
0 ELDO1 Enable Set RW X

AXP228 Datasheet V1.1 Copyright © 2012 X-Powers Limited. All Rights Reserved PAGE 28/52
X-Powers AXP228
Enhanced Single Cell Li-Battery and Power System Management IC

REG 13H:Power Output Control

Default:01H
Bit Description R/W Default
7 ALDO3 Enable Set 0:Off; 1:On RW 0
6-0 Reserved and unchangeable RW 0

REG 15H:DLDO1 Output Voltage Set

Default: 00H
Bit Description R/W Default
7-5 Reserved and unchangeable
4 DLDO1 Output Voltage Set Bit4 0.7-3.3V,100mV/step RW 0
3 DLDO1 Output Voltage Set Bit3 RW 0
2 DLDO1 Output Voltage Set Bit2 RW 0
1 DLDO1 Output Voltage Set Bit1 RW 0
0 DLDO1 Output Voltage Set Bit0 RW 0

REG 16H:DLDO2 Output Voltage Set

Default: 00H
Bit Description R/W Default
7-5 Reserved and unchangeable
4 DLDO2 Output Voltage Set Bit4 0.7-3.3V,100mV/step RW 0
3 DLDO2 Output Voltage Set Bit3 RW 0
2 DLDO2 Output Voltage Set Bit2 RW 0
1 DLDO2 Output Voltage Set Bit1 RW 0
0 DLDO2 Output Voltage Set Bit0 RW 0

REG 17H:DLDO3 Output Voltage Set

Default: 00H
Bit Description R/W Default
7-5 Reserved and unchangeable
4 DLDO3 Output Voltage Set Bit4 0.7-3.3V,100mV/step RW 0
3 DLDO3 Output Voltage Set Bit3 RW 0
2 DLDO3 Output Voltage Set Bit2 RW 0
1 DLDO3 Output Voltage Set Bit1 RW 0

AXP228 Datasheet V1.1 Copyright © 2012 X-Powers Limited. All Rights Reserved PAGE 29/52
X-Powers AXP228
Enhanced Single Cell Li-Battery and Power System Management IC

0 DLDO3 Output Voltage Set Bit0 RW 0

REG 18H: DLDO4 Output Voltage Set

Default: 00H
Bit Description R/W Default
7-5 Reserved and unchangeable
4 DLDO4 Output Voltage Set Bit4 0.7-3.3V,100mV/step RW 0
3 DLDO4 Output Voltage Set Bit3 RW 0
2 DLDO4 Output Voltage Set Bit2 RW 0
1 DLDO4 Output Voltage Set Bit1 RW 0
0 DLDO4 Output Voltage Set Bit0 RW 0

REG 19H: ELDO1 Output Voltage Set

Default: 00H
Bit Description R/W Default
7-5 Reserved and unchangeable
4 ELDO1 Output Voltage Set Bit4 0.7-3.3V,100mV/step RW 0
3 ELDO1 Output Voltage Set Bit3 RW 0
2 ELDO1 Output Voltage Set Bit2 RW 0
1 ELDO1 Output Voltage Set Bit1 RW 0
0 ELDO1 Output Voltage Set Bit0 RW 0

REG 1AH:ELDO2 Output Voltage Set

Default: 00H
Bit Description R/W Default
7-5 Reserved and unchangeable
4 ELDO2 Output Voltage Set Bit4 0.7-3.3V,100mV/step RW 0
3 ELDO2 Output Voltage Set Bit3 RW 0
2 ELDO2 Output Voltage Set Bit2 RW 0
1 ELDO2 Output Voltage Set Bit1 RW 0
0 ELDO2 Output Voltage Set Bit0 RW 0

REG 1BH:ELDO3 Output Voltage Set

Default: 00H
Bit Description R/W Default

AXP228 Datasheet V1.1 Copyright © 2012 X-Powers Limited. All Rights Reserved PAGE 30/52
X-Powers AXP228
Enhanced Single Cell Li-Battery and Power System Management IC

7-5 Reserved and unchangeable


4 ELDO3 Output Voltage Set Bit4 0.7-3.3V,100mV/step RW 0
3 ELDO3 Output Voltage Set Bit3 RW 0
2 ELDO3 Output Voltage Set Bit2 RW 0
1 ELDO3 Output Voltage Set Bit1 RW 0
0 ELDO3 Output Voltage Set Bit0 RW 0

REG 1CH:DC5LDO Output Voltage Set

Default: 04H
Bit Description R/W Default
7-3 Reserved and unchangeable
2 DC5LDO Output Voltage Set Bit2 0.7-1.4V,100mV/step RW 1
1 DC5LDO Output Voltage Set Bit1 RW 0
0 DC5LDO Output Voltage Set Bit0 RW 0

REG 21H: DC-DC1 Output Voltage Set

Default: 11H
Bit Description R/W Default
7-5 Reserved and unchangeable
4 DC-DC1 Output Voltage Set Bit4 1.6-3.4V,100mV/step RW 1
3 DC-DC1 Output Voltage Set Bit3 RW 0
2 DC-DC2 Output Voltage Set Bit2 RW 0
1 DC-DC2 Output Voltage Set Bit1 RW 0
0 DC-DC2 Output Voltage Set Bit0 RW 1

REG 22H: DC-DC2 Output Voltage Set

Default:19H
Bit Description R/W Default
7-6 Reserved and unchangeable
5 DC-DC2 Output Voltage Set Bit5 0.6-1.54V,20mV/step RW 0
4 DC-DC2 Output Voltage Set Bit4 RW 1
3 DC-DC2 Output Voltage Set Bit3 RW 1
2 DC-DC2 Output Voltage Set Bit2 RW 0
1 DC-DC2 Output Voltage Set Bit1 RW 0
0 DC-DC2 Output Voltage Set Bit0 RW 1

AXP228 Datasheet V1.1 Copyright © 2012 X-Powers Limited. All Rights Reserved PAGE 31/52
X-Powers AXP228
Enhanced Single Cell Li-Battery and Power System Management IC

REG 23H: DC-DC3 Output Voltage Set

Default: 19H
Bit Description R/W Default
7-6 Reserved and unchangeable
5 DC-DC3 Output Voltage Set Bit5 0.6-1.86V,20mV/step RW 0
4 DC-DC3 Output Voltage Set Bit4 RW 1
3 DC-DC3 Output Voltage Set Bit3 RW 1
2 DC-DC3 Output Voltage Set Bit2 RW 0
1 DC-DC3 Output Voltage Set Bit1 RW 0
0 DC-DC3 Output Voltage Set Bit0 RW 1

REG 24H: DC-DC4 Output Voltage Set

Default: 19H
Bit Description R/W Default
7-6 Reserved and unchangeable
5 DC-DC4 Output Voltage Set Bit5 0.6-1.54V,20mV/step RW 0
4 DC-DC4 Output Voltage Set Bit4 RW 1
3 DC-DC4 Output Voltage Set Bit3 RW 1
2 DC-DC4 Output Voltage Set Bit2 RW 0
1 DC-DC4 Output Voltage Set Bit1 RW 0
0 DC-DC4 Output Voltage Set Bit0 RW 1

REG 25H: DC-DC5 Output Voltage Set

Default:0AH
Bit Description R/W Default
7-5 Reserved and unchangeable
4 DC-DC5 Output Voltage Set Bit4 1.0-2.55V,50mV/step RW 0
3 DC-DC5 Output Voltage Set Bit3 RW 1
2 DC-DC5 Output Voltage Set Bit2 RW 0
1 DC-DC5 Output Voltage Set Bit1 RW 1
0 DC-DC5 Output Voltage Set Bit0 RW 0

REG 27H: DC-DC2/3 Dynamic Voltage Scaling Parameter Set

Default: 00H
Bit Description R/W Default

AXP228 Datasheet V1.1 Copyright © 2012 X-Powers Limited. All Rights Reserved PAGE 32/52
X-Powers AXP228
Enhanced Single Cell Li-Battery and Power System Management IC

7-4 Reserved and unchangeable


3 DC-DC3 VRC Enable Control RW 0
0:On; 1:Off
2 DC-DC2 VRC Enable Control RW 0
0:On; 1:Off
1 DC-DC3 VRC Voltage ramp 0: 20mV/15.625us=1.6mV/us RW 0
Control 1: 20mV/31.250us=0.8mV/us
0 DC-DC2 VRC Voltage ramp 0: 20mV/15.625us=1.6mV/us RW 0
Control 1: 20mV/31.250us=0.8mV/us

REG 28H: ALDO1 Output Voltage Set

Default: 00H
Bit Description R/W Default
7-5 Reserved and unchangeable
4 ALDO1 Output Voltage Set Bit4 0.7-3.3V,100mV/step RW 0
3 ALDO1 Output Voltage Set Bit3 RW 0
2 ALDO1 Output Voltage Set Bit2 RW 0
1 ALDO1 Output Voltage Set Bit1 RW 0
0 ALDO1 Output Voltage Set Bit0 RW 0

REG 29H: ALDO2 Output Voltage Set

Default: 0BH
Bit Description R/W Default
7-5 Reserved and unchangeable
4 ALDO2 Output Voltage Set Bit4 0.7-3.3V,100mV/step RW 0
3 ALDO2 Output Voltage Set Bit3 RW 1
2 ALDO2 Output Voltage Set Bit2 RW 0
1 ALDO2 Output Voltage Set Bit1 RW 1
0 ALDO2 Output Voltage Set Bit0 RW 1

REG 2AH:ALDO3 Output Voltage Set

Default: 17H
Bit Description R/W Default
7-5 Reserved and unchangeable
4 ALDO3 Output Voltage Set Bit4 0.7-3.3V,100mV/step RW 1

AXP228 Datasheet V1.1 Copyright © 2012 X-Powers Limited. All Rights Reserved PAGE 33/52
X-Powers AXP228
Enhanced Single Cell Li-Battery and Power System Management IC

3 ALDO3 Output Voltage Set Bit3 RW 0


2 ALDO3 Output Voltage Set Bit2 RW 1
1 ALDO3 Output Voltage Set Bit1 RW 1
0 ALDO3 Output Voltage Set Bit0 RW 1

REG 30H: VBUS-IPSOUT Path set

Default: 6XH
Bit Description R/W Default
7 VBUS-IPSOUT Path select Control when VBUS valid RW 0
0:decided by N_VBUSEN pin, N_VBUSEN=0,the path is on
1:VBUS-IPSOUT Path is On
6 VBUS VHOLD voltage limit set RW 1
0:not limited; 1:limited
5 VHOLD Set Bit 2 000: 4.0V; 001: 4.1V; 010: 4.2V RW 1
4 VHOLD Set Bit 1 011: 4.3V; 100: 4.4V; 101: 4.5V RW 0
3 VHOLD Set Bit 0 110: 4.6V; 111: 4.7V RW 0
2 DRIVEVBUS as GPO, Output Control RW 0
0: Output Low 1: Output High(IPSOUT)
1:0 VBUS current limit Control Set RW X
00 -900mA;01-500mA;1x-no current limit

REG 31H: Wakeup Control and Voff Voltage Set

Default:X3H
Bit Description R/W Default
7 PWROK status when Wakeup RW 0
0:do not output low 1:output low
6 Soft re-startup Control, write 1 to re-startup, then it self-clear RW 0
5 Software Wakeup Control, write 1 to restore the output voltage, then it RW 0
self-clear
4 When Wakeup function Enabled, IRQ triggered PMU Wakeup and IRQ
masked or not when Wakeup
0: IRQ triggered Wakeup,When Wakeup,all IRQ masked
1:IRQ work normal, but not triggered Wakeup
3 Wakeup Function Enable Set when Sleep
0: Wakeup function Off
1: Wakeup function On
It self-clear after write 1
2 VOFF Set Bit2 000-2.6V; 001-2.7V; 010-2.8V; RW 0
1 VOFF Set Bit1 011-2.9V; 100-3.0V; 101-3.1V; RW 1

AXP228 Datasheet V1.1 Copyright © 2012 X-Powers Limited. All Rights Reserved PAGE 34/52
X-Powers AXP228
Enhanced Single Cell Li-Battery and Power System Management IC

0 VOFF Set Bit0 110-3.2V; 111-3.3V RW 1

REG 32H: Power off Set 、 Battery detection and CHGLED Control

Default:43H
Bit Description R/W Default
7 Power off Control RW 0
Write 1 to power off all output except LDO1
6 Battery detection Set : 0:Off; 1:On RW 1
5-4 CHGLED PIN Set 00: High-Z RW 00
01: 25% 0.5Hz toggle
10: 25% 2Hz toggle
11: Output Low
3 CHGLED PIN Control Set 0: REGREG 32HBit[5:4] Control RW 0
1: Controlled by charge module
2 Sequence when Power Output Off RW 0
0:All Power Output Off at the same time
1:Reverse to the power on sequence
1-0 PWROK delay after Power 00: 8ms; 01: 16ms; RW 10
Output ready 10: 32ms; 11:64ms

REG 33H: Charge Control1

Default: CXH
Bit Description R/W Default
7 Charge Enable Control RW 1
0:Off, 1:On
6:5 Charge Voltage Set RW 10
00:4.1V; 01:4.22V; 10:4.2V; 11:4.24V
4 Charge end current Set RW 0
0: 10%
1: 15%
3-0 Charge current Set RW X
0000:300mA; 0001:450mA; 0010:600mA; 0011:750mA;
0100:900mA; 0101:1050mA; 0110:1200mA; 0111:1350mA;
1000:1500mA; 1001:1650mA; 1010:1800mA; 1011:1950mA;
1100:2100mA; 1101:2250mA; 1110:2400mA; 1111:2550mA

AXP228 Datasheet V1.1 Copyright © 2012 X-Powers Limited. All Rights Reserved PAGE 35/52
X-Powers AXP228
Enhanced Single Cell Li-Battery and Power System Management IC

REG 34H: Charge Control2

Default: 45H
Bit Description R/W Default
7 Pre-Charge timeout Set Bit1 00: 40 min; 01: 50min; RW 0
6 Pre-Charge timeout Set Bit0 10: 60min; 11: 70min RW 1
5 Charge Output Off or On when charge finished RW 000
0:Off; 1:On
4 CHGLED function type 0
0:A 1:B
3 Reserved and unchangeable 0
2 Charge target voltage follow with the charge current or not 0
0:On 1:Off
2 Charge external Path Enable Set RW 0
0:Off; 1:On
1 Constant Current timeout set Bit1 00: 6Hours; 01: 8Hours; RW 0
0 Constant Current timeout set Bit0 10: 10Hours; 11: 12Hours RW 1

REG 35H: Charge Control3

Default: 22H
Bit Description R/W Default
7:4 Reserved and unchangeable
3:0 Charge loop current limit Set RW 1110
0000:300mA; 0001:450mA; 0010:600mA; 0011:750mA;
0100:900mA; 0101:1050mA; 0110:1200mA; 0111:1350mA;
1000:1500mA; 1001:1650mA; 1010:1800mA; 1011:1950mA;
1100:2100mA; 1101:2250mA; 1110:2400mA; 1111:2550mA

REG 36H:PEK Parameter Set

Default:5DH
Bit Description R/W Default
7 Power on Time Set Bit1 00: 128mS; 01: 1S; RW 0
6 Power on Time Set Bit0 10: 2S; 11: 3S. RW 1
5 Long key Time Set Bit1 00: 1S; 01: 1.5S; RW 0
4 Long key Time Set Bit0 10: 2S; 11: 2.5S. RW 1
3 Hardwar Power off function Set when key down time longer than Power RW 1
off Time
0:Off; 1:On

AXP228 Datasheet V1.1 Copyright © 2012 X-Powers Limited. All Rights Reserved PAGE 36/52
X-Powers AXP228
Enhanced Single Cell Li-Battery and Power System Management IC

2 Re-startup or not after hardware power off RW 1


0:no; 1:yes
1 Power off time Set Bit1 00: 4S; 01: 6S; RW 0
0 Power off time Set Bit0 10: 8S; 11: 10S RW 1

REG 37H:DC-DC work frequency Set

Default: 08H
Bit Description R/W Default
7 DC-DC and charger frequency-spread Set 0
0:Off 1:On
6 DC-DC and charger spread frequency Set 0
0:50KHz 1:100KHz
5 Reserved and unchangeable
4 DC-DC 2&3 Poly-phase Function Set X
0:Off 1:On
3 DC-DCSwitch frequency Set Bit 3 5%/step,Default 3MHz RW 1
2 DC-DCSwitch frequency Set Bit 2 RW 0
1 DC-DCSwitch frequency Set Bit 1 RW 0
0 DC-DCSwitch frequency Set Bit 0 RW 0

REG 38H:VLTF-charge Battery Charge under temperature Set

Default:A5H
Bit Description R/W Default
7-0 Battery under temperature Set M*10H RW A5H
when charge,M M=A5H:2.112V
Range:0V~3.264V
VLTF-charge = M *10H * 0.0008V

REG 39H:VHTF-charge Battery Charge over temperature Set

Default:1FH
Bit Description R/W Default
7-0 Battery over temperature Set N*10H RW 1FH
when charge,N N=1FH:0.397V
range:0V~3.264V
VHTF-charge = N *10H * 0.0008V

AXP228 Datasheet V1.1 Copyright © 2012 X-Powers Limited. All Rights Reserved PAGE 37/52
X-Powers AXP228
Enhanced Single Cell Li-Battery and Power System Management IC

REG 3CH:VLTF-discharge Battery under temperature Set

Default: FCH
Bit Description R/W Default
7-0 Battery under temperature Set M*10H RW FCH
when discharge,M M=FCH:3.226V
Range:0V~3.264V
VLTF-discharge = M *10H* 0.0008V

REG 3DH:VHTF-discharge Battery over temperature Set

Default:16H
Bit Description R/W Default
7-0 Battery over temperature Set N*10H RW 16H
when discharge,N N=16H:0.282V
Range:0V~3.264V
VLTF-discharge = N *10H* 0.0008V

REG 80H:DC-DC Work mode

Default:80H
Bit Description R/W Default
7-5 Reserved and unchangeable
4 DC-DC5 Work mode Control 0:PFM/PWM auto switch RW 0
3 DC-DC4 Work mode Control 1:fixed PWM RW 0
2 DC-DC3 Work mode Control RW 0
1 DC-DC2 Work mode Control RW 0
0 DC-DC1 Work mode Control RW 0

REG 82H:ADC Enable

Default:83H
Bit Description R/W Default
7 Battery Voltage ADC Enable 0:Off, 1:On RW 1
6 Battery Current ADC Enable RW 0
5 Internal temperature ADC Enable RW 0
4-1 Reserved and unchangeable
0 TS Pin ADC Enable 0:Off, 1:On RW 1

AXP228 Datasheet V1.1 Copyright © 2012 X-Powers Limited. All Rights Reserved PAGE 38/52
X-Powers AXP228
Enhanced Single Cell Li-Battery and Power System Management IC

REG 84H:ADC Sample rate Set ,TS Pin Control

Default:32H
Bit Description R/W Default
n
7 ADC Sample rate Set Bit 1 10× 2 RW 0
6 ADC Sample rate Set Bit 0 Sample rate: RW 0
100, 200, 400, 800Hz
5-4 TS Pin Output Current Set : RW 11
00:20uA; 01:40uA; 10:60uA; 11:80uA
3 Reserved and unchangeable
2 TS Pin function RW 0
0: Battery temperature detection,1:ADC Input
TS Pin Current Output Set 00:Off RW 1
1-0 01: Output Current when charging RW 0
10:Output Current when ADC sample
11: always On

REG 85H:TS ADC Sample rate set

Default:X0H
Bit Description R/W Default
n
7 TS ADC Sample rate Set 1 10× 2 RW 0
6 TS ADC Sample rate Set 0 Sample rate 分别为 100,200,400, RW 0
800Hz
5-0 Reserved and unchangeable

REG 8AH:Timer Control

Default:00H
Bit Description R/W Default
7 Timer Timeout status: RW 0
1:timeout
Write 1 to clear this bit
6-0 Timer set,1min/step RW 0000000
Write 0 to disable the timer

REG 8CH:PWRENControl Set 1

Default:00H

AXP228 Datasheet V1.1 Copyright © 2012 X-Powers Limited. All Rights Reserved PAGE 39/52
X-Powers AXP228
Enhanced Single Cell Li-Battery and Power System Management IC

Bit Description R/W Default


7 DC-DC1 controlled by PWREN 0:yes 1:no RW 0
6 DC-DC2 controlled by PWREN RW 0
5 DC-DC3 controlled by PWREN RW 0
4 DC-DC4 controlled by PWREN RW 0
3 DC-DC5 controlled by PWREN RW 0
2 ALDO1 controlled by PWREN RW 0
1 ALDO2 controlled by PWREN RW 0
0 ALDO3 controlled by PWREN RW 0

REG 8DH:PWRENControl Set 2

Default:00H
Bit Description R/W Default
7 DLDO1 controlled by PWREN 0:yes 1:no RW 0
6 DLDO2 controlled by PWREN RW 0
5 DLDO3 controlled by PWREN RW 0
4 DLDO4 controlled by PWREN RW 0
3 ELDO1 controlled by PWREN RW 0
2 ELDO2 controlled by PWREN RW 0
1 ELDO3 controlled by PWREN RW 0
0 DC5LDO controlled by PWREN RW 0

REG 8FH:IC over temperature Power off function Set

Default:01H
Bit Description R/W Default
7 IRQ PIN triggered Power on or Wakeup function Set RW 0
0:Off 1:On
6 ACIN/VBUS In-short function Set RW 0
0:auto detection 1:set by REG8F_[5]
5 ACIN/VBUS In-short status and Set RW 0
0:not In-short 1:In-short
4 N_VBUSEN PIN function Control RW X
0: Output Pin ,as DRIVEVBUS function(Output to enable the OTG 5V
Boost module)
1:Input Pin , Control VBUS Path
3 Reserved and unchangeable
2 AXP228 internal over temperature Power off function Set RW 0
0:do not Power off ; 1: Power off
1-0 Reserved and unchangeable RW 01

AXP228 Datasheet V1.1 Copyright © 2012 X-Powers Limited. All Rights Reserved PAGE 40/52
X-Powers AXP228
Enhanced Single Cell Li-Battery and Power System Management IC

REG 90H:GPIO0 function Set

Default:07H
Bit Description R/W Default
7 GPIO0 posedge triggered IRQ/wakeup or not when as input RW 0
0:no 1: yes
6 GPIO0 negedge triggered IRQ/wakeup or not when as input RW 0
0:no 1: yes
5-3 Reserved and unchangeable
2 GPIO0 Pin Function Set Bit 2 000: Output low RW 1
001: Output High
010:input Function
1 GPIO0 Pin Function Set Bit 1 011: low noise LDO Function On RW 1
100:low noise LDO Function Off
0 GPIO0 Pin Function Set Bit 0 101-111: floating RW 1

REG 91H:GPIO0 work as LDO mode and Output voltage Set

Default:1FH
Bit Description R/W Default
7-5 Reserved and unchangeable
4 GPIO0 LDO Output Voltage Set 0.7-3.3V,100mV/step RW 0
Bit4
3 GPIO0 LDO Output Voltage Set RW 0
Bit3
2 GPIO0 LDO Output Voltage Set RW 0
Bit2
1 GPIO0 LDO Output Voltage Set RW 0
Bit1
0 GPIO0 LDO Output Voltage Set RW 0
Bit0

REG 92H:GPIO1 Function Set

Default:07H
Bit Description R/W Default
7 GPIO1 posedge triggered IRQ/wakeup or not when as input RW 0
0:no 1: yes
6 GPIO1 negedge triggered IRQ/wakeup or not when as input RW 0
0:no 1: yes

AXP228 Datasheet V1.1 Copyright © 2012 X-Powers Limited. All Rights Reserved PAGE 41/52
X-Powers AXP228
Enhanced Single Cell Li-Battery and Power System Management IC

5-3 Reserved and unchangeable


2 GPIO1 Pin Function Set Bit 2 000: Output low RW 1
001: Output High
010: input Function
1 GPIO1 Pin Function Set Bit 1 011: low noise LDO Function On RW 1
100:low noise LDO Function Off
0 GPIO1 Pin Function Set Bit 0 101-111: floating RW 1

REG 93H:GPIO1 work as LDO mode and Output voltage Set

Default:1FH
Bit Description R/W Default
7-5 Reserved and unchangeable
4 GPIO1 LDO Output Voltage Set 0.7-3.3V,100mV/step RW 0
Bit4
3 GPIO1 LDO Output Voltage Set RW 0
Bit3
2 GPIO1 LDO Output Voltage Set RW 0
Bit2
1 GPIO1 LDO Output Voltage Set RW 0
Bit1
0 GPIO1 LDO Output Voltage Set RW 0
Bit0

REG 94H:GPIO[1:0] input status

Default:00H
Bit Description R/W Default
7-2
1 GPIO1 input status 0:Low R
0 GPIO0input status 1:High R

REG 97H:GPIO[1:0] pull down resister Set

Default:00H
Bit Description R/W Default
7-2 Reserved and unchangeable
1 GPIO1 pull down Control when 0:pull down resistor off RW 0
work as input 1:pull down resistor on

AXP228 Datasheet V1.1 Copyright © 2012 X-Powers Limited. All Rights Reserved PAGE 42/52
X-Powers AXP228
Enhanced Single Cell Li-Battery and Power System Management IC

0 GPIO0 pull down Control when RW 0


work as input

REG 40H:IRQ Enable 1

Default:D8H
Bit Description R/W Default
7 ACIN over voltage IRQ Enable RW 1
6 ACIN insert IRQ Enable RW 1
5 ACIN remove IRQ Enable RW 0
4 VBUS over voltage IRQ Enable RW 1
3 VBUS insert IRQ Enable RW 1
2 VBUS remove IRQ Enable RW 0
1 VBUS valid but lower than VHOLDIRQ Enable RW 0
0 Reserved and unchangeable RW 0

REG 41H:IRQ Enable 2

Default:FFH
Bit Description R/W Default
7 Battery present IRQ Enable RW 1
6 Battery remove IRQ Enable RW 1
5 Battery enter active mode IRQ Enable RW 1
4 Exit Battery active mode IRQ Enable RW 1
3 Charging IRQ Enable RW 1
2 Charge finished IRQ Enable RW 1
1 Battery over temperature IRQ Enable RW 1
0 Battery under temperature IRQ Enable RW 1

REG 42H:IRQ Enable 3

Default:3BH
Bit Description R/W Default
7 AXP228 internal over temperature IRQ Enable RW 0
6-2 Reserved and unchangeable
1 Short key IRQ Enable RW 1
0 Long key IRQ Enable RW 1

AXP228 Datasheet V1.1 Copyright © 2012 X-Powers Limited. All Rights Reserved PAGE 43/52
X-Powers AXP228
Enhanced Single Cell Li-Battery and Power System Management IC

REG 43H:IRQ Enable 4

Default:C1H
Bit Description R/W Default
7-2 Reserved and unchangeable
1 Battery energy low warning level 1 IRQ Enable(information) RW 1
0 Battery energy low warning level 2 IRQ Enable(need to Power off) RW 1

REG 44H:IRQ Enable 5

Default:00H
Bit Description R/W Default
7 Timer Timeout IRQ Enable RW 0
6 PEK posedge IRQ Enable RW 0
5 PEK negedge IRQ Enable RW 0
4-2 Reserved and unchangeable
1 GPIO1 edge IRQ Enable RW 0
0 GPIO0 edge IRQ Enable RW 0

REG 48H:IRQ Status 1

Default:00H
Bit Description R/W Default
7 ACIN over voltage IRQ RW 0
6 ACIN insert IRQ RW 0
5 ACIN remove IRQ RW 0
4 VBUS over voltage IRQ RW 0
3 VBUS insert IRQ RW 0
2 VBUS remove IRQ RW 0
1 VBUS valid but lower than VHOLDIRQ RW 0
0 Reserved and unchangeable RW 0

REG 49H:IRQ Status 2

Default:00H
Bit Description R/W Default
7 Battery present IRQ RW 0
6 Battery remove IRQ RW 0
5 Battery enter active mode IRQ RW 0

AXP228 Datasheet V1.1 Copyright © 2012 X-Powers Limited. All Rights Reserved PAGE 44/52
X-Powers AXP228
Enhanced Single Cell Li-Battery and Power System Management IC

4 Exit Battery active mode IRQ RW 0


3 Charging IRQ RW 0
2 Charge finished IRQ RW 0
1 Battery over temperature IRQ RW 0
0 Battery under temperature IRQ RW 0

REG 4AH:IRQ Status 3

Default:00H
Bit Description R/W Default
7 AXP228 internal over temperature IRQ RW 0
6-2 Reserved and unchangeable
1 Short key IRQ RW 0
0 Long key IRQ RW 0

REG 4BH:IRQ Status 4

Default:00H
Bit Description R/W Default
7-2 Reserved and unchangeable
1 Battery energy low warning level 1 IRQ (information) RW 0
0 Battery energy low warning level 2 IRQ (need to Power off) RW 0

REG 4CH:IRQ Status 5

Default:00H
Bit Description R/W Default
7 Timer Timeout IRQ RW 0
6 PEK posedge IRQ RW 0
5 PEK negedge IRQ RW 0
4-2 Reserved and unchangeable
1 GPIO1 edge IRQ RW 0
0 GPIO0 edge IRQ RW 0
Note:Write 1 to these bit will clear the IRQ status

REG B8H:E-Gauge Control

Default:C0H

AXP228 Datasheet V1.1 Copyright © 2012 X-Powers Limited. All Rights Reserved PAGE 45/52
X-Powers AXP228
Enhanced Single Cell Li-Battery and Power System Management IC

Bit Description R/W Default


7 Gauge system Enable Control RW 1
0:Off 1:On
6 Coulomb counter Enable Control RW 1
0:Off 1:On
5 Battery full capacity calibration Function Enable RW 1
0:Off 1:On
4 Battery capacity calibration Status RW 0
0:do not at calibration status 1:calibrating now
3-0 Reserved and unchangeable RW 0

REG B9H: Battery Gauge result

Default:64H
Bit Description R/W Default
7 Battery result indication R 0
0:be calculated yet 1: calculating now
6-0 Battery gauge result 0%~100% R 64

REG E0H: Battery full design capacity Set 1

Default:00H
Bit Description R/W Default
7 Battery full design capacity configured or not RW 0
0:not be configured 1:has been configured
6-0 Battery full design capacity bit[14:8] RW
Battery full design capacity = Value * 1.456mAh

REG E1H: Battery full design capacity Set 2

Default:00H
Bit Description R/W Default
7-0 Battery full design capacity bit[7:0] RW

REG E6H: Battery low power warning level Set

Default:A0H
Bit Description R/W Default
7:4 Battery low power warning level 1 Set RW 1010

AXP228 Datasheet V1.1 Copyright © 2012 X-Powers Limited. All Rights Reserved PAGE 46/52
X-Powers AXP228
Enhanced Single Cell Li-Battery and Power System Management IC

0000-1111:5%-20%
6-0 Battery low power warning level 2 Set RW 0000
0000-1111:0%-15%

AXP228 Datasheet V1.1 Copyright © 2012 X-Powers Limited. All Rights Reserved PAGE 47/52
X-Powers AXP228
Enhanced Single Cell Li-Battery and Power System Management IC

11 PACKAGE

AXP228 Datasheet V1.1 Copyright © 2012 X-Powers Limited. All Rights Reserved PAGE 48/52

You might also like