Frame 1014L Winding M: Shunt

This document provides specifications for a 3-phase, 4-pole, shunt wound electric motor. Key details include: - Rated at 14-16kVA at 50Hz and 16-17.5kVA at 60Hz - Insulation class H, protection level IP23 - Excitation via integrated shunt wound exciter regulated by an R250 AVR - Efficiencies range from 81-88% depending on load level - Technical details like reactances, time constants, and locked rotor curves are specified.

Uploaded by

scribdledee
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
49 views3 pages

Frame 1014L Winding M: Shunt

This document provides specifications for a 3-phase, 4-pole, shunt wound electric motor. Key details include: - Rated at 14-16kVA at 50Hz and 16-17.5kVA at 60Hz - Insulation class H, protection level IP23 - Excitation via integrated shunt wound exciter regulated by an R250 AVR - Efficiencies range from 81-88% depending on load level - Technical details like reactances, time constants, and locked rotor curves are specified.

Uploaded by

scribdledee
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 3

FRAME 1014L WINDING M

MODELS LB1014L(X) (inc LLB / LUB / LFB) REF: F1004LWM-2 APRIL 2010

WINDING DETAILS MECHANICAL DETAILS


Code M Insulation class H Standard protection IP23
Phase 1 Leads 4 Overspeed rpm 2250
Pole number 4 Pitch 2/3 Air flow 50Hz/60Hz m3/s 0.15 / 0.18

EXCITATION DETAILS WAVEFORM


Excitation system SHUNT No load or linear rated load
AVR model R250 Total harmonic content THC <4%
Sustained short-circuit current - Telephone influence factor TIF (NEMA) <50
Steady state voltage regulation ±0.5% Telephone harmonic factor THF (IEC) <2%

VOLTAGE
Frequency / speed 50Hz / 1500rpm 60Hz / 1800rpm
Series V 220 230 240 220 230 240
Parallel V 110 115 120 110 115 120

1 2 3 4 6 7 8 9 10 11
RATING Power factor 1.0, Altitude <=1000m
Class H rise BR 125/40 kVA 14.0 14.0 14.0 16.0 16.0 16.0
kW 14.0 14.0 14.0 16.0 16.0 16.0
Class H rise PR 150/40 kVA 14.8 14.8 14.8 17.0 17.0 17.0
kW 14.8 14.8 14.8 17.0 17.0 17.0
Class H rise PR 163/27 kVA 16.0 16.0 16.0 17.5 17.5 17.5
kW 16.0 16.0 16.0 17.5 17.5 17.5
Class F rise BR 105/40 kVA 12.7 12.7 12.7 14.6 14.6 14.6
kW 12.7 12.7 12.7 14.6 14.6 14.6

EFFICIENCIES Power factor 1.0


110% Class H BR % 81.4 82.3 83.1 80.1 81.2 82.3
100% Class H BR % 82.9 83.7 84.3 81.1 82.2 83.2
75% Class H BR % 85.5 86.0 86.4 84.2 85.1 85.8
50% Class H BR % 87.6 87.7 87.7 86.9 87.4 87.8
25% Class H BR % 87.1 86.6 86.0 87.4 87.4 87.2

CHARACTERISTIC PARAMETERS Reactance base class H BR rating


Kc Short-circuit ratio 0.43 0.50 0.56 0.27 0.29 0.35
Xd D-Axis synchronous reactance (unsaturated) pu 1.89 1.73 1.58 2.59 2.37 2.17
X'd D-Axis transient reactance (saturated) pu 0.30 0.27 0.25 0.41 0.37 0.34
X''d D-Axis sub-transient reactance (saturated) pu 0.148 0.135 0.124 0.202 0.185 0.170
Xq Q-Axis synchronous reactance (unsaturated) pu 0.94 0.86 0.79 1.29 1.18 1.09
X''q Q-Axis sub-transient reactance (saturated) pu 0.211 0.193 0.177 0.290 0.265 0.243
X2 Negative-sequence reactance (saturated) pu - - - - - -
X0 Zero-sequence reactance (independent) pu - - - - - -
T'd D-Axis transient time constant ms 40 40
T''d D-Axis sub-transient time constant ms 6 6
T'do D-Axis open-circuit time constant ms 340 340
Ta Armature time constant ms 8 8
Tr Voltage recovery time ms < 500 < 500

EXCITATION VOLTAGE AND CURRENT

No load excitation voltage V 12.3 13.5 14.9 9.0 9.4 10.1


No load excitation current A 0.52 0.57 0.63 0.38 0.40 0.43
Class H BR excitation voltage V 30.4 30.2 30.4 30.4 29.5 28.6
Class H BR excitation current A 1.29 1.28 1.29 1.29 1.25 1.21

WINDING RESISTANCE At 20 o C
Stator (series) Ω 0.250 Exciter field Ω 23.6
Main field Ω 2.30

According to: IEC 60034, UTE NFC51.111, VDE 0530, BS 4999/5000, NEMA MG 1-33
Values quoted are typical. In line with our policy of continuous improvement, we reserve the right to change specification without notice.
FRAME 1014L WINDING M

MODELS LB1014L(X) (inc LLB / LUB / LFB) REF: F1004LWM-2 APRIL 2010

LOCKED ROTOR MOTOR STARTING CURVES Power factor 0.9

50 Hz SHUNT

220V

230V

240V
35

30

25
voltage dip %

20

15

10

0
0 5 10 15 20 25
kVA

60 Hz SHUNT
220V
230V
240V

35

30

25
voltage dip %

20

15

10

0
0 5 10 15 20 25
kVA

According to: IEC 60034, UTE NFC51.111, VDE 0530, BS 4999/5000, NEMA MG 1-33
Values quoted are typical. In line with our policy of continuous improvement, we reserve the right to change specification without notice.
FRAME 1014L WINDING M

MODELS LB1014L(X) (inc LLB / LUB / LFB) REF: F1004LWM-2 APRIL 2010

SHORT-CIRCUIT DECREMENT CURVES No-load excitation at rated speed

230V 50Hz Series

1000 asymmetrical
RMS current (A)

symmetrical

100

10
1 10 100 1000 10000
time (ms)

Multiplication Factors

50Hz Voltages 220 230 240

Multiplication Factor 0.96 1.00 1.04

Apply factor up to 2xT'd, remainder of curve unchanged

60Hz Voltages 220 230 240

Multiplication Factor 0.80 0.83 0.87

Apply factor up to 2xT'd, remainder of curve unchanged

Winding Connection Series Parallel

Multiplication Factor 1.00 2.00

Apply factor to the complete curve

According to: IEC 60034, UTE NFC51.111, VDE 0530, BS 4999/5000, NEMA MG 1-33
Values quoted are typical. In line with our policy of continuous improvement, we reserve the right to change specification without notice.