Control Valves 412-1412 - En.08.02.01-05.183
Control Valves 412-1412 - En.08.02.01-05.183
CONTROL VALVES
Type
Presentación de la compañía
412
HISTORY Over fifty years experience in fluid power. Supplier to international manufactures of agricultural, construction, mining, mechanical handling,
machine-tool and food machinery. Main supplier to the Spanish market with rapidly increasing presence in European and world markets.
TECHNOLOGY Roquet has a large design and development department with substantial fatigue, noise, corrosion-resistance, cleanliness and testing
facilites, backed by a well-equipped metallurgical laboratory.
RELIABILITY A broad range of robust products: designed to perform, built to last. All products ranges life-tested under realistic conditions during
development to ensure their suitability for use in applications such as tractors, fork-lift trucks, loaders, excavators, cranes, dumpers, dock-levellers...
Each and every product tested to a stringent test specification prior to shipment.
CAPABILITY 400 well trained empoyees. Four factories with a total floor area of 30.000m² Current production 180.000 pumps, 300.000 control valve
bodies, 500.000 cylinders and 30.000 power packs per year. Distribution network in over 35 countries.
2
Type
412
This range of directional control valves is primarily intended for applications such as construction, material handling and agricultural machinery etc.
The valves are actuated by hand-levers, pneumatic operated, cable operated, etc.
Index
This Catalogue shows the product in the most standard configuration; customized or special designs are also avaible, please contact to PEDRO
ROQUET S.A. The specifications and data in this catalogue are not open to any interpretation, please contact with PEDRO ROQUET S.A. in case of
doubt.
PEDRO ROQUET S.A. reserves the right to modify, update or revise this catalogue without prior notice.
PEDRO ROQUET S.A. IS NOT RESPONSABLE FOR ANY DAMAGE CAUSED BY AN INCORRECT USE OF THE PRODUCT.
3
Type
Directional control valves
412
412
Technical data
Type Parallel
Spool force 18 Kg / 40 Lb
4
Type
Directional control valve curves
412
Diagrams
P→T
24 (348)
12
22 (319) 11
10
20 (290) 9
8
18 (260) 7
6
16 (230)
5
14 (200)
p=bar
(psi)
4
12 (175)
3
10 (145)
8 (115) 2
6 (85) 1
4 (60)
2 (30)
Relief valve
10 20 30 40 50 60 70 80
(2.6) (5.3) (7.9) (10) (13) (16) (19) (21) 250 (3625)
Q=L/min 230 (3335)
(US GPM)
210 (3045)
190 (2755)
170 (2465)
150 (2175)
p=bar
130 (1885)
(psi)
110 (1595)
90 (1305)
70 (1015)
50 (725)
30 (435)
10 (145)
10 20 30 40 50 60
(2.6) (5.3) (7.9) (10) (13) (16)
P→T2 Q=L/min
60 (870)
(US GPM)
12
11 Minimal pressure curve
10
50 (725) 9
8
7
6
40 (580)
5
p=bar
(psi)
4
30 (435)
20 (290) 2
10 (145)
10 20 30 40 50 60 70 80
(2.6) (5.3) (7.9) (10) (13) (16) (19) (21)
Q=L/min
(US GPM)
5
Type
Directional control valve curves
412
P→A or B
24 (348)
22 (319)
20 (290)
18 (260)
12
16 (230) From 1 to 12 elements
1
14 (200)
p=bar
(psi)
12 (175)
10 (145)
8 (115)
6 (85)
4 (60)
2 (30)
10 20 30 40 50 60 70 80
(2.6) (5.3) (7.9) (10) (13) (16) (19) (21)
Q=L/min
(US GPM)
32 (464) 21
30 (435)
321
28 (406)
26 (378) 4321
24 (348)
54321
22 (319)
20 (290) 654321
p=bar
7654321
(psi)
18 (260)
16 (230)
87654321
14 (200)
987654321
12 (175)
10 (145) 10 9 8 7 6 5 4 3 2 1
8 (115)
11 10 9 8 7 6 5 4 3 2 1
6 (85)
2 (30)
10 20 30 40 50 60 70 80
(2.6) (5.3) (7.9) (10) (13) (16) (19) (21)
Q=L/min
(US GPM)
6
Type
Directional control valve dimensions
412
°
ion 25° ª position 25
30 Nm
14º
Torque:
208
22 Lb-ft
4
14º
56
4ª posit
130
P
100,5
90
68
23 26
63
53
32,5
184 51
14,5
64 64 D
220
94 127
P1 T2
41,5
SPOOL DETAIL END
21
22 Ø9 H9
94 127
Ø15
7
8,3
72
Normal positions
11
Ø14,8
38,5
Mounting Holes Ø9 T T1
A B 5 (1 position) 5 (2 position)
38
(0 position)
E
C
A B
Special positions
38
P1 T2
42
23,5
(0 position)
73
FREE FLOW
NOTE:
Port A is always next to operator side even if the section is assembled with levers on the other side. T-T1-T2 All are tank ports
T Power
C (mm) 118 156 194 232 270 308 346 384 422 460 498 536
T1-T2 Tank port
D (mm) 116 154 192 230 268 306 345 382 420 458 496 534
E (mm) 146 184 222 260 298 336 374 412 450 488 526 564 CLOSED CENTER
Weight in kg 5 8 11 14 17 20 23 26 29 32 35 38 T Closed
Weight in Lb 11 17,5 24,3 31 37,5 44,3 51 57,5 64,3 71 77,5 84,3 T1-T2 Tank port
7
Type
Directional control valve, general view
412
Spool position
Operator side
kit side
PLUG
PLUG
Hydraulic circuit
Hydraulic scheme with Hydraulic scheme with main relief Hydraulic scheme with main relief
main relief valve. valve and auxiliary valves. valve and unloading valve.
T T1 T T1 T T1
A2 B2 A2 B2 A2 B2
A1 B1 A1 B1 A1 B1
P1 P T2 P1 P T2
P1 P T2
8
Type
Identification control valve parts
412
4 Hand lever
3 Spool position
Inlet cover
Auxiliary valve
6 Relief valve
9
Type
Coding system
412
24 24 V
4 Operators
10
Type
Coding system
412
Code
Code
Control valve type
Code
Microswitch
(page: 29)
Control valve type Auxiliary valve pressure range (pressure set al 22l/min.)
Auxiliary valves
12
Type
Inlet section details
412
9803003
Hydraulic unloading
valve kit
* **
97180 3/ - 8411273 224901
* 224904
*
Electric unloading Main relief Main relief valve with
valve kit valve kit Tamper proof kit
13
Type
Inlet section details
412
Unloading valve
97180 3/
T
Power (W)
Connector type
P 30 30 W
** VDC ** W
100% ED
0 HIRSCHMANN
Voltage (DC)
2 DEUTSCH
D12 12 V
D24 24 V
Technical data
Technical data
14
Type
Operating section details
412
Spool types
D I U
3 position, 4-way, double acting, A and B ports 3 position, 4-way, double acting, A and B ports 3 position, 4 -way, double acting, A and B
blocked in 0 position. open to tank in 0 position. ports restricted to tank in 0 position.
T T T
A B A B A B
S V L
3 position, 3 -way, single acting, A port 3 position, 3-way, single acting, B port blocked 4 position, 4-way, double acting, A and B port
blocked in position 0, B port plugged. in position 0, A port plugged. blocked in position 0, 4th position float.
T T T
A B A B A B
15
Type
Operating section details
412
Three positions with detent. Two positions with detent, third position return by spring.
2 0 1 2 0 1
51
51
Two ends positions with detent. Three positons return to neutral by spring.
2 1
2 0 1
51 51
Two positions, neutral and end position by detent, Four positions three return by spring the fourth detented pulling spool.
action pushing spool.
2 1
51
81
Two positions, neutral and end position by detent, action pulling spool. Three positions. Central by spring and two end positions with detent.
2 1
51 81
16
Type
Operating section details
412
One end position and neutral position with detents, action pushing One end position with detent, action pulling spool; Neutral and other
spool; and other end position by spring, end position by spring, action pushing spool.
action pulling spool.
2 0 1 2 0 1
51
81
75 P.N. M8412/227
One end position with detent, action pushing spool; Neutral and other
end position by spring, action pulling spool.
2 0 1
81
Operators
D2 Is the same operator rotated 180º but de not allow port vales options
M.8x14
14º
M.8
14º
17
Type
Operating section details
412
Operators
114
90
25
Ø 15
7
9
25 (neutral position)
51
NOTE:
Only includes pieces with mark
65
NOTE:
14º degree at all directions. 270
M.6
85
18
Type
Operating section details
412
Auxiliary valves
Auxilary
Plug
relief valve
M6412/113/1
*
2VSD /SA
Auxilary
Anticavitation valve
relief valve
VA 2VSD /SA
*
2VSD /VA 2VSD /VA
19
Type
Operating section details
412
Auxiliary valves
T A-B T
p=bar
p=bar
(psi)
18 (260)
(psi)
250 (3625)
200 (2900)
p=bar
A-B
(psi)
150 (2175)
50 (725)
0
T
0 10 20 30 40 50 60 70 80 90 100
(2.6) (5.3) (7.9) (10) (13) (16) (19) (21) (24) (26)
Q=L/min
(US GPM)
Anticavitation P.N. VA
32 (465)
30 (435)
28 (405)
26 (380)
24 (350)
22 (320)
20 (290)
p=bar
(psi)
18 (260)
16 (230)
14 (205)
12 (175)
T A-B 10 (145)
T A-B 8 (115)
6 (90)
4 (60)
2 (30)
10 20 30 40 50 60 70 80 90 100
(2.6) (5.3) (7.9) (10) (13) (16) (19) (21) (24) (26)
Q=L/min
(US GPM)
20
Type
Operating section details
412
Rotative operator
Spool position
Operator (R) kit (35)
º
90
90
º
131
51,8
48
5,5
48
5,5
T T1
37
P T2
NOTE: Rotative pilot normally use a stainless steel spool. Spool position type 35 and operator type R standard P.N. 8412283001
21
Type
Operating section details
412
65 48 Spool position
Operator (R)
kit (35)
48
T T1
37
P T2
65 48
5,5 5,5
90
90
Neutral Neutral
position (0) position (0)
90
º
90
º
22
Type
Operating section details
412
88
6
Plug AUXILIARY Plug
VALVES
127
314
NOTE:
When ordering spool position kit 83 “A” main relief valve postion must be used.
Spool position kit 84, according main relief valve in A (Standard) position Kit converter to spool kit type 84.
P.N.: M7799/5/84/85
Connection
236
280
NOTE:
In spool position kit 84, solenoid side is considered operator side.
280 (4060)
240 (3480)
200 (2900)
Coil connector Required connector
Operator Hand lever IP-Protector 200 (2320)
(Female) (Male)
p=bar
(psi)
160 (2320)
E without DEUTSCH DT04-2P DEUTSCH DT06-2S 67
120 (1740)
80 (1160)
Spool
Main relief 40 (580)
position Function Description
Valve position 0
Kit
10 20 30 40 50
(2.6) (5.3) (7.9) (10) (13)
A 83 Three positions; end positions by direct sole-
2 0 1 Q=L/min
noid, neutral position by spring.
(US GPM)
Two positions; neutral position and end po-
A-C 84 sition. Position 0 by spring and end position
by solenoid in side A port.
Ambient operating
Coil voltage Coil wattage Coil resistance Duty Coil insulation
Temperature (Coil)
12 V DC 42 W 3,25 Ohm continuous (100%) -54ºC (-65ºF) / +60ºC (+140ºF) CLASS H
23
Type
Operating section details
412
17º
Spool position kit 83 17
º
193
86
86
NOTE:
When ordering spool position kit 83
with emergency operator “A” main
6
127 42
relief position valve must be used. 345
Connection
NOTE:
In spool position kit 84,
with emergency operator,
solenoid side is considered 268
operator side. 311
280 (4060)
240 (3480)
200 (2900)
Coil connector Required connector 200 (2320)
Operator Hand lever IP-Protector
p=bar
(Female) (Male)
(psi)
160 (2320)
80 (1160)
Spool 40 (580)
Main relief
position Function Description 0
Valve position
Kit 10 20 30 40 50
(2.6) (5.3) (7.9) (10) (13)
Ambient operating
Coil voltage Coil wattage Coil resistance Duty Coil insulation
Temperature (Coil)
12 V DC 42 W 3,25 Ohm continuous (100%) -54ºC (-65ºF) / +60ºC (+140ºF) CLASS H
24
Type
Operating section details
412
Pneumatic pilot
NOTE:
Pneumatic pilot normally use an operator type Z2 (standard), S or T. If you want use another type of operator for this pneumatic pilot, please contact.
1/8” NPT
1/8” NPT
120
80
6
Plug AUXILIARY VALVES Plug
49 127 99
100
90
Ø15
80
% Full Flow
7
70
60
50
40
9 30
20
25 (neutral position) 10
0
0 0,5 1 1,5 2 2,5 3 3,5 4 4,5 5 5,5 6 6,5 7 7,5 8 8,5 9 9,5 10
Pressure in Pilot Line (bar) Hysteresis Cycle
Pneumatic Pilot
Entry by LARGE Chamber
51 100
90
80
% Full Flow
70
60
50
40
30
20
10
0
0 0,5 1 1,5 2 2,5 3 3,5 4 4,5 5 5,5 6 6,5 7 7,5 8 8,5 9 9,5 10
Pressure in Pilot Line (bar) Hysteresis Cycle
S
Z2 22 Three positions pneumatic piloted.
T
25
Type
Operating section details
412
Hydraulic pilot
NOTE:
Hydraulic pilot only use spool position kit 71 and operator Y.
1/8” G 1/8” G
86
6
Plug AUXILIARY VALVES Plug
127
235
Hydraulic Pilot
100
90
80
70
% Full Flow
60
50
40
30
20
10
0
0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30
26
Type
Operating section details
412
Spool position
Operator side (E)
kit (83)
126
315
Spool position
Operator side (Z2)
kit (11)
126
227
246
27
Type
Additional sections
412
This flow control section can be fitted at any position in valve assembly except final section, according to which sections are required with a
reduced flow rate.
All sections downstream of this valve can only operated at this reduced flow rate.
T T
P
82
PP1
6 137 max 23
166
NOTE:
Not possible reduce flow on final section.
3 way flow control ajustable P.N. M7792002 3 way flow control with knob P.N. M7792003
36
38
74,5
PP PP
PP1 PP1
T PP P T
T1 PP1 P1 T1
Technical data
28
Type
Mid-outlet details
412
Mid-outlet scheme
P1 P T2
A1
B1
A2
1/8”G. B2
1/2”G.
1/4”G. 1/4”G.
A3
T B3
T1
B3
A3
T1
1/2”G.
B2
82
A2
1/4”G.
B1
A1
P1 P T2
4 137 38
A1
B1
1/8”G.
1/2”G. A2
1/4”G. 1/4”G. B2
A3
B3
T T
T1
B3
T1
1/2”G.
A3
82
B2
1/4”G.
A2
B1
A1
4 137 38
P1 P T2
29
Type
Mid-outlet details
412
P1 P T2
200 bar
A1
B1
1/8”G.
1/2”G. A2
1/4”G. 1/4”G. B2
A3
B3
Tp Tp
T1
B3
T1
1/2”G.
A3
82
B2
1/4”G.
A2
B1
A1
200 bar
4 137 38
P1 P T2
Return configuration
Z
C
Ports
Return type Part number
T
30
Type
Operating section details
412
Position microswitch *
NOTE:
Seal is required
181
114
86
6
127 39
266
31
Type
Request a ROQUET control valve
412
Spool position: Auxiliary valve: Section: Without valve Auxiliary valve: Hand lever:
Section: With valve
9
Corredera:
Spool position: Auxiliary valve: Section: Without valve Auxiliary valve: Hand lever:
Section: With valve
8
Corredera:
Spool position: Auxiliary valve: Section: Without valve Auxiliary valve: Hand lever:
Section: With valve
7
Corredera:
Spool position: Auxiliary valve: Section: Without valve Auxiliary valve: Hand lever:
Section: With valve
6
Corredera:
Spool position: Auxiliary valve: Section: Without valve Auxiliary valve: Hand lever:
Section: With valve
4
Corredera:
Spool position: Auxiliary valve: Section: Without valve Auxiliary valve: Hand lever:
Section: With valve
3
Corredera:
Spool position: Auxiliary valve: Section: Without valve Auxiliary valve: Hand lever:
Section: With valve
2
Corredera:
Spool position: Auxiliary valve: Section: Without valve Auxiliary valve: Hand lever:
Section: With valve
1
Corredera:
Operative port:
Top port
Front port
Type Return S. p. device Hand lever Position Setting Spools Voltage Unloading valve Code
32
Type
Notes
412
33
www.pedro-roquet.com
www.ciandisseny.com
EN.08.02.01/05.18