Test Report No. F690101/LF-CTSAYGU20-00379 Issued Date : 2020. 01.
09 Page 1 of 7
POONGSAN CORPORATION
94 Sanam-ro,Onsan-eup
Ulju-gun,Ulsan
Korea
The following sample(s) was/were submitted and identified by/on behalf of the client as:-
SGS File No. : AYGU20-00379
Product Name : C2600-Tin Plated
Item No./Part No. : Brass
Received Date : 2020. 01. 02
Test Period : 2020. 01. 02 to 2020. 01. 09
Test Results : For further details, please refer to following page(s)
SGS Korea Co., Ltd.
/ LTS Busan Laboratory
Thomas Hwang / Lab Manager
This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at <http://www.sgs.com/en/Terms-and-Conditions.aspx>
and, for electronic format documents, subject to Terms and Conditions for Electronic Documents at https://www.sgs.com/en/terms-and-conditions/terms-e-document . Attention is drawn to the
limitation of liability, indemnification and jurisdiction issues defined therein. Any holder of this document is advised that information contained hereon reflects the Company’s findings at the time
of its intervention only and within the limits of Client’s instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from
exercising all their rights and obligations under the transaction documents. This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized
alteration, forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law. Unless otherwise stated the results
shown in this test report refer only to the sample(s).
CBQP-7081-F01 (01) 50, Sinsan-ro 29beon-gil, Saha-gu, Busan, Korea 49432
t +82 (0)51 795 7300 f +82 (0)51 795 7310 http://www.sgsgroup.kr
SGS Korea Co.,Ltd.
Member of the SGS Group (Société Générale de Surveillance)
Test Report No. F690101/LF-CTSAYGU20-00379 Issued Date : 2020. 01. 09 Page 2 of 7
Sample No. : AYGU20-00379.001
Sample Description : C2600-Tin Plated
Item No./Part No. : Brass
Materials : N/A
Heavy Metals
Test Items Unit Test Method MDL Results
Cadmium (Cd) mg/kg With reference to IEC 62321-5:2013(Determination 0.5 N.D.
of Cadmium by ICP-OES)
Lead (Pb) mg/kg With reference to IEC 62321-5:2013(Determination 5 11.0
of Lead by ICP-OES)
Mercury (Hg) mg/kg With reference to IEC 62321-4:2013(Determination 2 N.D.
of Mercury by ICP-OES)
Hexavalent Chromium (Cr VI) * µg/cm² With reference to IEC 62321-7-1:2015 0.1 N.D.
(Determination of CrVI by UV-Vis)
Beryllium (Be) mg/kg With reference to EPA 3052(1996), US EPA 5 N.D.
6010B(1996), ICP
Flame Retardants-PBBs/PBDEs
Test Items Unit Test Method MDL Results
Monobromobiphenyl mg/kg With reference to IEC 62321-6:2015 (Determination 5 N.D.
of PBBs and PBDEs by GC-MS)
Dibromobiphenyl mg/kg With reference to IEC 62321-6:2015 (Determination 5 N.D.
of PBBs and PBDEs by GC-MS)
Tribromobiphenyl mg/kg With reference to IEC 62321-6:2015 (Determination 5 N.D.
of PBBs and PBDEs by GC-MS)
Tetrabromobiphenyl mg/kg With reference to IEC 62321-6:2015 (Determination 5 N.D.
of PBBs and PBDEs by GC-MS)
Pentabromobiphenyl mg/kg With reference to IEC 62321-6:2015 (Determination 5 N.D.
of PBBs and PBDEs by GC-MS)
Hexabromobiphenyl mg/kg With reference to IEC 62321-6:2015 (Determination 5 N.D.
of PBBs and PBDEs by GC-MS)
Heptabromobiphenyl mg/kg With reference to IEC 62321-6:2015 (Determination 5 N.D.
of PBBs and PBDEs by GC-MS)
Octabromobiphenyl mg/kg With reference to IEC 62321-6:2015 (Determination 5 N.D.
of PBBs and PBDEs by GC-MS)
Nonabromobiphenyl mg/kg With reference to IEC 62321-6:2015 (Determination 5 N.D.
of PBBs and PBDEs by GC-MS)
Decabromobiphenyl mg/kg With reference to IEC 62321-6:2015 (Determination 5 N.D.
of PBBs and PBDEs by GC-MS)
This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at <http://www.sgs.com/en/Terms-and-Conditions.aspx>
and, for electronic format documents, subject to Terms and Conditions for Electronic Documents at https://www.sgs.com/en/terms-and-conditions/terms-e-document . Attention is drawn to the
limitation of liability, indemnification and jurisdiction issues defined therein. Any holder of this document is advised that information contained hereon reflects the Company’s findings at the time
of its intervention only and within the limits of Client’s instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from
exercising all their rights and obligations under the transaction documents. This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized
alteration, forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law. Unless otherwise stated the results
shown in this test report refer only to the sample(s).
CBQP-7081-F01 (01) 50, Sinsan-ro 29beon-gil, Saha-gu, Busan, Korea 49432
t +82 (0)51 795 7300 f +82 (0)51 795 7310 http://www.sgsgroup.kr
SGS Korea Co.,Ltd.
Member of the SGS Group (Société Générale de Surveillance)
Test Report No. F690101/LF-CTSAYGU20-00379 Issued Date : 2020. 01. 09 Page 3 of 7
Sample No. : AYGU20-00379.001
Sample Description : C2600-Tin Plated
Item No./Part No. : Brass
Materials : N/A
Flame Retardants-PBBs/PBDEs
Test Items Unit Test Method MDL Results
Monobromodiphenyl ether mg/kg With reference to IEC 62321-6:2015 (Determination 5 N.D.
of PBBs and PBDEs by GC-MS)
Dibromodiphenyl ether mg/kg With reference to IEC 62321-6:2015 (Determination 5 N.D.
of PBBs and PBDEs by GC-MS)
Tribromodiphenyl ether mg/kg With reference to IEC 62321-6:2015 (Determination 5 N.D.
of PBBs and PBDEs by GC-MS)
Tetrabromodiphenyl ether mg/kg With reference to IEC 62321-6:2015 (Determination 5 N.D.
of PBBs and PBDEs by GC-MS)
Pentabromodiphenyl ether mg/kg With reference to IEC 62321-6:2015 (Determination 5 N.D.
of PBBs and PBDEs by GC-MS)
Hexabromodiphenyl ether mg/kg With reference to IEC 62321-6:2015 (Determination 5 N.D.
of PBBs and PBDEs by GC-MS)
Heptabromodiphenyl ether mg/kg With reference to IEC 62321-6:2015 (Determination 5 N.D.
of PBBs and PBDEs by GC-MS)
Octabromodiphenyl ether mg/kg With reference to IEC 62321-6:2015 (Determination 5 N.D.
of PBBs and PBDEs by GC-MS)
Nonabromodiphenyl ether mg/kg With reference to IEC 62321-6:2015 (Determination 5 N.D.
of PBBs and PBDEs by GC-MS)
Decabromodiphenyl ether mg/kg With reference to IEC 62321-6:2015 (Determination 5 N.D.
of PBBs and PBDEs by GC-MS)
Phthalates
Test Items Unit Test Method MDL Results
Di-(2-ethylhexyl) phthalate (DEHP) mg/kg With reference to IEC 62321-8:2017, GC/MS 50 N.D.
Di-butyl phthalate (DBP) mg/kg With reference to IEC 62321-8:2017, GC/MS 50 N.D.
Benzyl butyl phthalate (BBP) mg/kg With reference to IEC 62321-8:2017, GC/MS 50 N.D.
Di-isobutyl phthalate (DIBP) mg/kg With reference to IEC 62321-8:2017, GC/MS 50 N.D.
This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at <http://www.sgs.com/en/Terms-and-Conditions.aspx>
and, for electronic format documents, subject to Terms and Conditions for Electronic Documents at https://www.sgs.com/en/terms-and-conditions/terms-e-document . Attention is drawn to the
limitation of liability, indemnification and jurisdiction issues defined therein. Any holder of this document is advised that information contained hereon reflects the Company’s findings at the time
of its intervention only and within the limits of Client’s instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from
exercising all their rights and obligations under the transaction documents. This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized
alteration, forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law. Unless otherwise stated the results
shown in this test report refer only to the sample(s).
CBQP-7081-F01 (01) 50, Sinsan-ro 29beon-gil, Saha-gu, Busan, Korea 49432
t +82 (0)51 795 7300 f +82 (0)51 795 7310 http://www.sgsgroup.kr
SGS Korea Co.,Ltd.
Member of the SGS Group (Société Générale de Surveillance)
Test Report No. F690101/LF-CTSAYGU20-00379 Issued Date : 2020. 01. 09 Page 4 of 7
NOTE: (1) N.D. = Not detected.(<MDL)
(2) mg/kg = ppm
(3) MDL = Method Detection Limit
(4) - = No regulation
(5) Negative = Undetectable / Positive = Detectable
(6) ** = Qualitative analysis (No Unit)
(7) * = a. The sample is positive for CrVI if the CrVI concentration is greater than 0.13 ug/cm2. The sample coating
is considered to contain CrVI.
b. The sample is negative for CrVI if CrVI is n.d. (concentration less than 0.10 ug/cm2). The coating is
considered a non-CrVI based coating.
c. The result between 0.10 ug/cm2 and 0.13 ug/cm2 is considered to be inconclusive - unavoidable coating
variations may influence the determination.
(8) The results shown in this test report refer only to the sample(s) tested unless otherwise stated.
This test report is not related to Korea Laboratory Accreditation Scheme .
Picture of Sample as Received:
AYGU20-00379.001
This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at <http://www.sgs.com/en/Terms-and-Conditions.aspx>
and, for electronic format documents, subject to Terms and Conditions for Electronic Documents at https://www.sgs.com/en/terms-and-conditions/terms-e-document . Attention is drawn to the
limitation of liability, indemnification and jurisdiction issues defined therein. Any holder of this document is advised that information contained hereon reflects the Company’s findings at the time
of its intervention only and within the limits of Client’s instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from
exercising all their rights and obligations under the transaction documents. This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized
alteration, forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law. Unless otherwise stated the results
shown in this test report refer only to the sample(s).
CBQP-7081-F01 (01) 50, Sinsan-ro 29beon-gil, Saha-gu, Busan, Korea 49432
t +82 (0)51 795 7300 f +82 (0)51 795 7310 http://www.sgsgroup.kr
SGS Korea Co.,Ltd.
Member of the SGS Group (Société Générale de Surveillance)
Test Report No. F690101/LF-CTSAYGU20-00379 Issued Date : 2020. 01. 09 Page 5 of 7
Testing Flow Chart for RoHS:Cd/Pb/Hg/Cr6+ /PBBs&PBDEs Testing
Sample cutting / weighing
Sample Preparation
6+
Cr
Cd/Pb/Hg PBBs/PBDEs
Acid Digestion with Sample Solvent Nonmetallic Metallic
Microwave/Hotplate Extraction Material Material
Concentration/Dilution Boiling water
Filtration Dissolving by Digesting at
of Extraction Solution extraction
ultrasonication 150~160℃
Solution Residue
Filtration Digestion at Separating to Adding
60℃ by get aqueous 1,5-diphenylcar
ultrasonication phase bazide for color
1) Alkali Fusion /
Dry Ashing GC/MS
2) Acid to
UV-Vis
dissolve pH adjustment
DATA
DATA
Adding
ICP-OES/AAS 1,5-diphenylcarbazide
for color
DATA
UV-Vis
DATA
The samples were dissolved totally at the acid digestion step of the above flow chart for Cd,Pb,Hg
- Technician : Gihwan Kim/Choah Jeong/Taehee Kang
- Supervisor : Thomas Hwang
This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at <http://www.sgs.com/en/Terms-and-Conditions.aspx>
and, for electronic format documents, subject to Terms and Conditions for Electronic Documents at https://www.sgs.com/en/terms-and-conditions/terms-e-document . Attention is drawn to the
limitation of liability, indemnification and jurisdiction issues defined therein. Any holder of this document is advised that information contained hereon reflects the Company’s findings at the time
of its intervention only and within the limits of Client’s instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from
exercising all their rights and obligations under the transaction documents. This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized
alteration, forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law. Unless otherwise stated the results
shown in this test report refer only to the sample(s).
CBQP-7081-F01 (01) 50, Sinsan-ro 29beon-gil, Saha-gu, Busan, Korea 49432
t +82 (0)51 795 7300 f +82 (0)51 795 7310 http://www.sgsgroup.kr
SGS Korea Co.,Ltd.
Member of the SGS Group (Société Générale de Surveillance)
Test Report No. F690101/LF-CTSAYGU20-00379 Issued Date : 2020. 01. 09 Page 6 of 7
Flow Chart for Inorganic Elements Testing
Inorganic Elements
Mechanic_Sample
Sample Measurement
Acid Digestion with
Microwave/Hotplate
Filtration
Residue
Total Digestion
ICP-AES
DATA
Major Inorganic Antimony(Sb) , Beryllium(Be) , Phosphorus(P) ,
Heavy Metals Arsenic(As) etc.
- Technician : Gihwan Kim
- Supervisor : Thomas Hwang
This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at <http://www.sgs.com/en/Terms-and-Conditions.aspx>
and, for electronic format documents, subject to Terms and Conditions for Electronic Documents at https://www.sgs.com/en/terms-and-conditions/terms-e-document . Attention is drawn to the
limitation of liability, indemnification and jurisdiction issues defined therein. Any holder of this document is advised that information contained hereon reflects the Company’s findings at the time
of its intervention only and within the limits of Client’s instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from
exercising all their rights and obligations under the transaction documents. This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized
alteration, forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law. Unless otherwise stated the results
shown in this test report refer only to the sample(s).
CBQP-7081-F01 (01) 50, Sinsan-ro 29beon-gil, Saha-gu, Busan, Korea 49432
t +82 (0)51 795 7300 f +82 (0)51 795 7310 http://www.sgsgroup.kr
SGS Korea Co.,Ltd.
Member of the SGS Group (Société Générale de Surveillance)
Test Report No. F690101/LF-CTSAYGU20-00379 Issued Date : 2020. 01. 09 Page 7 of 7
Flow Chart for Phthalate Test
Sample pretreatment / Separation
Sample dissolved / extracted by THF
Dilute Extracted solution
Analysis was performed by GC/MS
Data
- Technician : Yukyung Park
- Supervisor : Thomas Hwang
*** End of Report ***
This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at <http://www.sgs.com/en/Terms-and-Conditions.aspx>
and, for electronic format documents, subject to Terms and Conditions for Electronic Documents at https://www.sgs.com/en/terms-and-conditions/terms-e-document . Attention is drawn to the
limitation of liability, indemnification and jurisdiction issues defined therein. Any holder of this document is advised that information contained hereon reflects the Company’s findings at the time
of its intervention only and within the limits of Client’s instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from
exercising all their rights and obligations under the transaction documents. This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized
alteration, forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law. Unless otherwise stated the results
shown in this test report refer only to the sample(s).
CBQP-7081-F01 (01) 50, Sinsan-ro 29beon-gil, Saha-gu, Busan, Korea 49432
t +82 (0)51 795 7300 f +82 (0)51 795 7310 http://www.sgsgroup.kr
SGS Korea Co.,Ltd.
Member of the SGS Group (Société Générale de Surveillance)