RKI H2O2 Sensor Specification ES - ESM-23dh - H2o2

This document provides the specifications for an RKI sensor that measures hydrogen peroxide (H2O-2) levels between 0-3 ppm. The sensor has a fast warm-up time, good zero stability, and quick response time of 90 seconds. It operates between -20°C and +45°C temperature with 10-95% humidity and has an expected life of 2-3 years. The sensor measures within +/- 10% accuracy and has potential interference from various gases that are listed along with their cross-sensitivities.

Uploaded by

Jainil Panchal
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
142 views1 page

RKI H2O2 Sensor Specification ES - ESM-23dh - H2o2

This document provides the specifications for an RKI sensor that measures hydrogen peroxide (H2O-2) levels between 0-3 ppm. The sensor has a fast warm-up time, good zero stability, and quick response time of 90 seconds. It operates between -20°C and +45°C temperature with 10-95% humidity and has an expected life of 2-3 years. The sensor measures within +/- 10% accuracy and has potential interference from various gases that are listed along with their cross-sensitivities.

Uploaded by

Jainil Panchal
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

RKI Sensor Specification

Features: Fast warm-up time Hydrogen Peroxide (H2O2)


Good zero stability Part Number: ES/ESM-23DH-H2O2
GD-K8A, GD-K7D2, GD-K71D,
Quick response time Sensor Application:
Eagle, GD-K77D

Technical Specifications
+/- 10% of reading or
Measuring Principle Amperometric 3-electrode sensor Accuracy +/- 5% of full scale
(whichever is greater)
Range of Measurement 0 – 3 ppm Repeatability +/- 5% of reading
T90 Response time
Resolution 1% of full scale 90 seconds
(20°C, 2 min. exposure)

Operating Conditions
Temperature Range -20°C to +45°C Life Expectancy 2-3 Years
Humidity Range 10-95% RH, Non Condensing Warranty 1 Year

Known Gas Interferences


PPM Gas PPM Gas
Gas Reading Gas Reading
Applied Applied
Acetone ((CH3)2CO) 1.0 % vol 1.0 ppm Hydrogen Chloride (HCl) 14.5 ppm 4.1 ppm
Ammonia (NH3) 250 ppm 1.1 ppm Hydrogen Selenide (SeH2) 5.2 ppm 4.1 ppm
Arsine (AsH3) 5.2 ppm 5.0 ppm Hydrogen Sulfide (H2S) 3.2 ppm 4.1 ppm
Isopropyl Alcohol (IPA)
Carbon Dioxide (CO2) 99.9 % vol 0.1 ppm
((CH3)2CHOH) 1.0 % vol 1.4 ppm
no
Carbon Monoxide (CO) 1250 ppm 4.1 ppm Methane (CH4)
1.0 % vol response
Chlorine (Cl2) 7.2 ppm -4.1 ppm Nitrogen (N2) 99.9 % vol 0.03 ppm
Diborane (B2H6) 4.5 ppm 4.1 ppm Nitric Oxide (NO) 100 ppm -0.29 ppm
Disilane (Si2H6) 1.0 ppm 4.1 ppm Nitrogen Dioxide (NO2) 4.8 ppm -4.1 ppm
Germanium Tetrahydride
1.1 ppm 4.1 ppm Phosphine (Ph3)
(GeH4) 0.5 ppm 2.0 ppm
Hydrogen (H2) 0.25 % vol 4.1 ppm Sulfur Dioxide (SO2) 4 ppm 4.1 ppm

Part # Prefix Applicable Instruments


ES GD-K8A, GD-K7D2, Eagle
ESM GD-K71D, GD-K77D