Citizen M320LC-V Reinitialize and Restore Procedure L16 L20 Machines

This document provides instructions to initialize, format, and load canned cycles for a Citizen 320LC L1620 control that has become non-functional, or "brain dead". The procedure involves reinitializing the control's memory, setting it to English, loading parameters and I/O settings from an electronic backup, formatting the memory, and then loading canned cycles, programs, tool data, and other files to restore the control's functionality. It takes several steps to reset dip switches, enter commands, and input settings and files using the control's interface.

Uploaded by

sunhuynh
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
2K views6 pages

Citizen M320LC-V Reinitialize and Restore Procedure L16 L20 Machines

This document provides instructions to initialize, format, and load canned cycles for a Citizen 320LC L1620 control that has become non-functional, or "brain dead". The procedure involves reinitializing the control's memory, setting it to English, loading parameters and I/O settings from an electronic backup, formatting the memory, and then loading canned cycles, programs, tool data, and other files to restore the control's functionality. It takes several steps to reset dip switches, enter commands, and input settings and files using the control's interface.

Uploaded by

sunhuynh
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 6

MELDAS

Citizen 320LC L1620 Reinitialize

USA-E02051-006*

MITSUBISHI ELECTRIC AUTOMATION

USA
List of Revisions

Date of
Rev Revision Detail Author
* 2/26/10 First Edition TSS
M300 Series
- M320LC -
Initialize, Format and Load Canned Cycles with an Electronic Backup for L16/L20 Machines
Purpose:
To initialize, format and load canned cycles from a brain dead control on a Citizen 300 series control
with an electronic backup.

Overview:
The procedure will take a locked up or brain dead control and restore the control back into working
condition. This procedure may need to be done if the battery fails, the control is powered off for a
long time or if the CPU fails. After the memory contents are erased and formatted then the canned
cycles and data can be loaded back in and the control will be back up to prior operation.

\Tools Needed:
• Electronic copy of machine data
• Small flat head screwdriver

Instructions:
I. Reinitializing the Control
A. Power Off the control.
B. On the MC116 set dip switches 1 and 3 to the right.
C. Power On the control.
D. The two green LED’s on the MC116 will turn on, then off and then on again. (The lights may
turn on and off real quickly. Wait at least 30 seconds before going to the next step.)
E. Power Off the control.
F. Set dip switch 2 to the right as well so the top three dip switches are to the right.
G. Power on the control for 1 minute. (This does a board recognition, you will not notice anything in
particular on the control or screen when doing this.)
H. Power Off the control.
I. Set dip switches 1 and 2 back to the left on the MC116.
J. On the MC116 keep dip switch 3 to the right.
II. Setting the Control Back into English
A. Power On the control.
B. Press [DGN] hard key.
C. Press [I/F] soft key.
D. Type in 1001 for device and M for mode.
Device Data Mode
(1001)( )(M)
E. Press Input. (If done correctly the 1001 and M will disappear.)
F. Press [PRA] hard key.
G. Press Left soft key.
H. Page over to page 5/7 or 8/10.
I. Change parameter #24 lang to a 1.
#( 24)Data( 1)
J. Press Input. The control is now in English. (You may need to change pages to see the effect.)

www.meau.com Mitsubishi Electric Automation, Inc. Page 1 of 4


M300 Series
- M320LC -
Initialize, Format and Load Canned Cycles with an Electronic Backup for L16/L20 Machines
III. Load Parameters
A. Press [DGN] hard key.
B. Press [PLC I/F] soft key.
C. Type in 300 for device and S for mode.
Device Data Mode
( 300)( )(S)
D. Press Input. (If done correctly the 300 and S will disappear.)
E. Press [DATA] hard key.
F. Press Menu until you Param.
G. Press [Param]
H. Hand type in the I/O parameters.
I. Press Menu until you see Input.
J. Press [Input].
K. Type in (#3) and hit Input.
L. Send the file over from your computer. (When loaded the control will say Data in Completed.)
IV. Store parameters into EEPROM
A. Press [DGN] hard key.
B. Press [PLC I/F] soft key.
C. Type in 1001 for device and M for mode.
Device Data Mode
(1001)( )(M)
D. Press [PRA] hard key.
E. Press [Base] or [Setup] soft key.
F. Page over to page 6/7 for Base or 9/10 for Setup.
G. Change parameter #32 EEROM to a 0.
#( 32)Data( 0)
H. Press Input. (The data in EEROM will change to other values and change back to 0)
I. Power Off the control.
J. On the MC116 set dip switch 3 back to the left.
V. Format and Load Canned Cycles
A. Power On the control.
B. Press [DGN] hard key.
C. Press [PLC I/F] soft key.
D. Type in 1001 for device and M for mode.
Device Data Mode
(1001)( )(M)
E. Press Input. (If done correctly the 1001 and M will disappear.)
F. Press [PRA] hard key.
G. Press [Setup] soft key.
H. Page over to page 8/10.
I. Change parameter #6 fix_p to a 1.
#( 6)Data( 1)
J. Press Input.
K. Change parameter #7 edlk_c to a 0.
#( 7)Data( 0)
L. Press Input.
M. Press [Data] hard key.
www.meau.com Mitsubishi Electric Automation, Inc. Page 2 of 4
M300 Series
- M320LC -
Initialize, Format and Load Canned Cycles with an Electronic Backup for L16/L20 Machines
N. Press Menu until you see Erase.
O. Press [Erase] soft key.
P. Arrow over to the second bracket and type in FORMAT.
#( )Data(FORMAT )
Q. Press Input. (The control will say Erase Complete.)
R. Press [Input] soft key.
S. Next to the # type in 4 and hit Input.
#( 4)Data( )
T. Once the control says Data in Complete the fixed cycles are loaded.
U. Press [PRA] hard key.
V. Press [Setup] soft key.
W. Page over to page 8/10.
X. Change parameter #6 fix_p to a 0.
#( 6)Data( 0)
Y. Press Input.
Z. Change parameter #7 edlk_c to a 1.
#( 7)Data( 1)
AA. Press Input.
BB. Power Off/On.
VI. Load Files
A. Set dip switch 2 on the MC116 to the right.
B. Press [Data] hard key
C. Press Menu until you see Input
D. Press [Input] soft key.
E. Re-input #1 (programs), #2 (tool data), #99 ALL1, #99 ALL2 and #99 ALL3.
F. Power Off.
G. Turn off dip switch 2 on the MC116.
H. Power On.
I. Press [DGN] hard key.
J. Press [PLC I/F] soft key.
K. Type in 1001 for device and M for mode.
Device Data Mode
(1001)( )(M)
L. Press Input. (If done correctly the 1001 and M will disappear.)
M. Press [PRA] hard key.
N. Press [Cus-Var] soft key.
O. Hand type in the custom variables. (Make sure to enter in zeros for customer variables that do
not have values or you will get incorrect machine operations and other errors.)
VII. Finish Machine Setup
A. Press [OFS] hard key.
B. Hand type in T-OFSET, T-DATA, and Nose-R.
C. Press [STAT] hard key.
D. Press Menu.
E. Hand type in COM-V.1, COM-V.2, and LOC-VAR.

www.meau.com Mitsubishi Electric Automation, Inc. Page 3 of 4


M300 Series
- M320LC -
Initialize, Format and Load Canned Cycles with an Electronic Backup for L16/L20 Machines
Appendix:
If you get M02 need R.P. RTN alarm message just zero return all axis on the machine
individually. You may need to open up the soft limits if you get alarm M01 0007 while trying to
home out the axis the first time after doing this procedure. After you get the axis zero returned
check home return positions and adjust zero points if necessary by adjusting parameter
G28SFT.

www.meau.com Mitsubishi Electric Automation, Inc. Page 4 of 4