Basic Type Weighing Indicator: Specifications

1. The document describes the specifications of a basic type weighing indicator that can be combined with a set point unit to form a measuring instrument. 2. It has a high display resolution of 1/10000 at all input ranges and a DIN-size format for easy installation. 3. Key features include analog and digital filtering, high accuracy even at low weights, and multiple digital and analog interfaces for connectivity options.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
85 views1 page

Basic Type Weighing Indicator: Specifications

1. The document describes the specifications of a basic type weighing indicator that can be combined with a set point unit to form a measuring instrument. 2. It has a high display resolution of 1/10000 at all input ranges and a DIN-size format for easy installation. 3. Key features include analog and digital filtering, high accuracy even at low weights, and multiple digital and analog interfaces for connectivity options.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

F701 BASIC TYPE WEIGHING INDICATOR

Specifications

ANALOG Excitation voltage DC10V±5% Output current: within 120mA


Remote sense type (Up to 4 units of 350 loadcells can be connected in parallel)
Zero adjustment range Rough adjustment: Input of approx. 0.5mV/V or 1.0mV/V selectable adjust
to zero by dip switch on the rear panel
HI gain: 0 ~ 1.5mV/V LO gain: 0 ~ 3.0mV/V
Fine adjustment: Automatic adjustment by digital processing.
Span adjustment range Rough adjustment: 2-stage gain can be selected according to load cell
output (via switch on the rear panel)
HI gain: 0.5 ~ 1.5 mV/V LO gain: 1.0 ~ 3.0 mV/V
Fine adjustment: Automatic adjustment by digital processing.
Min. input sensitivity 0.5μV/count
Accuracy Non-linearity .................. within 0.01%/FS
Zero drift ......................... within 0.2μV/℃ RTI (Typ 0.15μV/℃)
Gain drift ......................... within 15 ppm/℃ (Typ 7 ppm/℃)
Noise.............................. within0.1μVp-p RTI (0.1ޯ10Hz)
Analog filter Bessel type low-pass filter (-12dB/oct.)
DIN Selectable from 2,4,6,8 Hz
192 ×96 A/D converter Speed .............. 100 times/sec
Resolution ......... 16 bit (binary)
DISPLAY Numeric display Numerical display of 18.5 mm
character height via vacuum fluorescent display (7 digits)
● The basic type of weighing indicator. Weighing value display 5 digit, Signs: Minus sign on most significant digit

● Can be combined with a set point unit to form a measuring Unit Selectable from lb, N, kg, g, t, none
Status display SP3/ SP2/ SP1/ LOCK/ ZT/ ZALM/ STAB/ TARE/ NET/ GROSS/ HILIM/ HI/
instrument. GO/ LO/ LOLIM/ HOLD/ NZ
SETTING Setting ・HI/ LO / Near Zero/ SP1/ SP2/ Compensation/ Over/ Under/ Final
● High display resolution item ・Comparison Inhibit Time/ Judging Time/ Complete Output Time/ Adjust Feeding Time/
AZ Times/ Judging Times/ Auto FF Compensation Regulation/ Tare Weight
1/10000 resolution at all input range is assured. ・Weighing Function 1/ Weighing Function 2/ Weighing Function 3/ Sequence Mode/
● DIN-size Function Key Inhibit/ Filter/ Motion Detect/ Zero Tracking/Setting Value Lock
・Balance Weight/ Capacity/ Min. Scale Division/ Net Weight Over/ Gross Weight Over/
DIN-size 192 x 96 for easy installation DZ Regulation/ Function Selection/ Gravitational Acceleration Compensation
・D/A Output Mode/ D/A Zero Output Weight/ D/A Full Scale/ RS-232C & RS-485 I/F Setting/
ID Setting/ External Setter Selection/ Extended Function Selection 1 / Compliance With
Set Point Unit E780 Measurement Law
・Span Calibration / Zero Calibration
※With its push-type digital switch, the final cut-off value is easily set to the F701 EXTERNAL Near Zero/ SP1/ SP2/ SP3/ Final . Complete/ Over/ Under/ Hi/ Lo/ Stable/
External
※
The select signal selects which of the set point unit that had been pre-set SIGNAL Weight Error . Error/ Run
output signal
(12) Transistor open collector output (Emitter = COM terminal)
with the final cut off value to use. Output is set to LO when transistor is ON. Vceo=30V(MAX), lc=50mA(MAX)
External Feed . Discharge/ Tare On/ Tare Off/ Digital Zero/G.N/ HOLD . Judgment/ Start/ Stop
input signal Set to ON when shorted to COM terminal through contact point (relay, switch etc.)
(8) or non-contact point (transistor, open collector output such as TTL etc.) Ic=10mA or lower
INTERFACE ・SIF: 2-wire type serial interface
・SPI: Interface for the setpoint (option)
・232: RS-232C communication Interface(option)※
・BCO: BCD parallel data output interface (option)
・485: RS-485 communication interface(option)※
・DAC: D/A converter Interface (option)
F701  Exclusive slot for D/A option is available
Select signal Only up to 2 other options can be installed
(however, Serial communication interface (※) is 1 option only.)
GENERAL Power supply voltage AC85ޯ110V, 102ޯ132V, 170ޯ220V,187ޯ242V
SPECIFICATIONS (Please specify when ordering) 50/60Hz 
Select signal
Power consumption 15VA
Operation condition Temperature .................... Operation temperature:−10ޯ+40℃
Storage temperature:−20ޯ+85℃
Select signal Humidity ......................... 85%RH or less (non-condensing)
External dimension 192(W)×96(H)×160(D)mm (not including protrusions)
Weight Approx. 2.2kg
ATTACHMENTS AC input cord (Nominal rating 125V) 2m ........... 1 Set point unit connector.....................................1
Select signal Spare fuse (1A) .................................................. 1 (when set point unit option is selected)
Mini driver........................................................... 1 BCD output connector .....................................1
Loadcell input connector (JRCconnector) .......... 1 (When BCD output option is selected)
57 series 24pconnector ...................................... 1 D/A converter connector.................................1
Set Point Unit E780 Operational Manual ............................................ 1 (when D/A converter option is selected)
OPTIONAL E780: Set point unit
ACCESSORIES CAAC2P-P2: AC input cord 2m
CAAC3P-CEE7/7-P1.5:AC input cord (Voltage resistance: 250 V) 1.5m
CA4131: (6-wired) cable with JRC connector at one end 3m
External Dimension CA4230: JRC-PRC (6-wired) conversion relay cable 0.3m
CA7: Coaxial cable with BNC at both ends 1.5m
(Front View) CA8: BNC alligator clip cable 1.5m
(Side View) CA3150: Sag-type flat cable with 57F / 36 pins termination 0.5m
CA4311: JRC-PRC (6-wired)conversion relay cable 1m (4-wired to 6-wired)
(for 520A)
CN21: 57 series 36p connector for BCD output and set point unit
CN23: 57 series 24p connector for external input/output
CN35: D-sub25p connector for RS-232C
CN3P-2P: 3P-2P converter plug for AC input cord
LB01-NH: Lithium battery (with NH connector)

10 150

(Rear View)

Panel cut dimension


92 +1
−0
91

185 186 +2
−0

Unit: mm