Access Control Programming Guide
Access Control Programming Guide
The device is a single entry standalone Access Control with integrated keypad Surface Finish Powder Coat Wire Insulation Colour Function Notes
and card reader. It is an easy to install and operate device, designs in as less Dimensions L120 X W76 X H25 (mm) (Wide)
Easy Keypad
Request to Exit input(REX) Power
Yellow OPEN
as 6 wires for mounting, with user-friendly programming. The compact design L130 X W56 X H23 (mm) (Narrow) 12-24V DC/3A
makes it a good choice for door access. Unit Weight 470g(Wide)/490g(Narrow) Red Power + 9-18 Votes DC Regulated Power Input
Shipping Weight 550g(Wide)/550g(Narrow) Black GND Ground
The device is housed in a strong Zinc Alloy electroplated case. It supports up to Normally Open Relay Output Exit Button NC COM NO 12-24V GND PUSH
White NO
1000 users in multiple access configurations (Card Only, Card or PIN, or
(Outdoor)
Brown COM Common Connection for Relay Output
Card + PIN). The built in card reader supports EM 125KHz frequency cards. Carton Inventory
Green NC Normally closed Relay Output
Two Versions Optional:
_ _
1) Indoor, nonwaterproof Yellow + +
Connection Diagram OPEN
2) Outdoor,Waterproof(IP66) Electric bolt Electric strike
1N4004
Normal Users 990 Green NC Electric Bolt: NC LOCK between 0 ~ 989.The PIN is any
NC + Programming will vary depending on access configuration. Follow the
Visitor Users 10 > Remove the back cover from the unit instructions according to your access configuration. 4-6 digits between 0000 ~ 999999
Operating Voltage 9-18V DC > Drill 2 holes(A,C) on the wall for the screws and one hole for the cable
Keypad 2 (Read Card) #
> Knock the supplied rubber bungs to the screw holes(A,C) Common Power Supply Delete User
Idle Current 50mA > Fix the back cover firmly on the wall with 4 flat head screws 2 (User ID) #
Active Current 80mA > Thread the cable through the cable hole(B)
Programming 1 Configure the device
Exit from the programming mode
Keypad 12 Key > Attach the unit to the back cover.
Attention: Install a 1N4004 or equivalent diode is needed when use a Change the configure settings according to your application (optional). How to be granted access.
Proximity Card Reader EM Multiple configuration settings can be changed at one time: enter program
Radio Technology 125 KHz Industry Standard Proximity Card common power supply, or the keypad might be damaged. Card User Read card
(1N4004 is included in the packing) mode, change desired settings, then exit program mode.
Read Range 3-6cm PIN User Enter (PIN) #
Wiring Connections Relay Output, Exit Button 1 2 3
Set Master Code
4 5 6
Relay One (NO, NC, Common) 7 8 9 The 4-6 digit Master Code is used to prevent unauthorized access to the
Adjustable Relay Output Time 0-99 Seconds (5 seconds default) 0 # system. To interface with the device the manager will need a Master Code
Lock Output Load 3 Amp Maximum (factory default code: 6666). We highly recommend immediate update and
Environment Meets IP66 record of your Master Code.
User Manual Operating Temperature -40℃~60℃, -40℉~140℉
Operating Humidity 10%-90% Non-condensing
Programming Step Keystroke Combination Set Strike-out Alarm 2. Add Card: Using Auto ID 1 (Read Card) #
Change a PIN Visitor User Setting Sound and Light Indication
1. Enter Program Mode (Master Code) # The strike-out alarm will engage after 5 failed card/PIN attempts. Default is (Allows the device to assign Card Cards can be added continuously. This operation is executed from outside of Program Mode. There are 10 groups Visitor PIN/card available, the users can be Operation Status Red LED Green LED Sounds
OFF. The strike-out alarm can be set to deny access for 10 minutes after specified up to 10 times of usage, after a certain number of times, Bright Short Single Beep
to next available User ID number) Programming Step Keystroke Combination Power on
0 ( New Master Code) # engaging or it can be set disengage only after entering a valid card/PIN or i.e. 5 times, the PIN/card become invalid automatically.
2. Update Master Code OR Stand by Bright
( Repeat New Master Code) # Master code. 1 (User ID) # (Read Card) # (User ID #) (Old PIN #)
2. Add Card: Select Specific ID 1. Change a PIN Press Keypad Flashing Short Single Beep
3. Exit Program Mode Programming Step Keystroke Combination (Allows manager to define a The user ID is any number from (New PIN #) (New PIN #) Programming Step Keystroke Combination Enter Master Code Entry Mode ON Short Single Beep
specific User ID to associate the 0~989.
1. Enter Program Mode (Master Code) # 1. Enter Program Mode (Master Code) # In program mode ON Single Flash Short Single Beep
card to)
Set Access Configuration 2. Strike-Out OFF 6 0 # (factory default) ACCESS CONFIGURATION: CARD+PIN------------------------------------ 2. Add Visitor PIN User 8 (0~9 #) (User ID #) (PIN #) Entered Program Step
3. Exit Program Mode Successfully ON Single Flash Short Single Beep
There are 3 types of access configurations for the device OR Add a Card+ PIN User PIN is any 4~6 digits number except 1234
> Card or PIN (Default): The User must present a valid Card to the device or 2. Strike-Out ON 6 1 # Access will be denied for OR Entered Program Step Incorrectly Short Single Beep
enter their PIN code followed by the # key, in order to be granted access. OR 10 minutes Programming Step Keystroke Combination 2. Add Visitor Card User 8 (0~9 #) (User ID #) (Read Card #) Exit from the programming mode Bright 3 Short Beeps
> Card Only: The User must present a valid Card to the device in order to be Delete User Cards 1. Enter Program Mode (Master Code) # 2 (User ID #) Entry Granted ON Short Single Beep
2.Delete Visitor Users
granted access. 2. Strike-Out ON 6 2 # The buzzer alarms. Open lock Green light bright One beep
Programming Step Keystroke Combination 2. Add a User Card by ID number 1 (User ID) # (Read Card) #
> Card + PIN: The User must first present a valid Card to the device and then 3. Exit Program Mode Alarm Mode Engaged Flashing Alarm
enter their PIN code followed by the # key, in order to be granted access. Set alarm time 5 (0 ~ 30) #, 1. Enter Program Mode (Master Code) # 3. Exit Program Mode
Factory default is 1 minute. Note: Red light Shines
2. Delete Card: By card 2 (Read Card) # (Read Card) (1234#) Alarm Beeps
Number of time is 0~9, 0=10 times quickly
Programming Step Keystroke Combination 3. Exit Cards can be deleted continuously. (New PIN #) (New PIN #)
4. Add PIN User ID number must be any number between 990~999 Pressing * Toggles Standby /
1. Enter Program Mode (Master Code) # OR This operation is executed from Visitor PIN/card must be unique, should be distinguished from ON/Flashing Short Single Beep
Master Code Entry
outside of Program Mode common PIN and card
2. Card or PIN 3 0 # Programming 2 Program Cards and PINS 2. Delete Card: Select Specific ID 2 (User ID) #
OR The user ID is any number from
2. Card + PIN 3 1 # Programming will vary depending on the access configuration. Follow the 0~989. Change PIN
OR instructions according to your access configuration.
2. Card only 3 2 # 3. Exit Allows card user to update the PIN for their card + PIN User ID. This OTHERS
GENERAL PROGRAMMING INFORMATION operation is executed from outside of Program Mode. Reset to Factory Default:
3. Exit Program Mode > User ID Number: Assign a user ID number to the access code in order to 1. Power off
keep track of the users of access cards or PINS. The nomral user ID can be Programming Step Keystroke Combination
2. Press the * Button, hold it and power on
any number from 0~989, and the 10 groups of visitoris from 990~999. Add or Delete a PIN 1. Change PIN using a Card (Read Card) (Old PIN #) 3. There will be two beeps, release the button, then will have one beep
Set Relay Configuration IMPORTANT: User IDs do not have to be proceeded with any leading zeros. The device reset to factory default successfully.
Programming Step Keystroke Combination (New PIN #) (New PIN #)
The relay configuration sets the behaviour of the output relay on activation. Recording of User ID is critical. Modifications to user data require either the OR
card or the User ID be available. 1. Enter Program Mode (Master Code) # 1. Change PIN using ID (User ID #) (Old PIN #) Remark: Reset to factory default, the user’s information is still
Programming Step Keystroke Combination > Proximity Card: 125 KHz industry standard 26 bits EM Proximity Card. retained.
2. Add a PIN 1 (User ID) # (PIN) # (New PIN #) (New PIN #)
1. Enter Program Mode (Master Code) # > Keypad PIN: The PIN can be any 4~6 digits between 0000~999999 (except
Assigns PIN to user ID number PINS can be added continuously. Erase all Users
1234 which is reserved for factory testing).
2. Pulse Mode 4 (1-99) # OR This will delete ALL User data.
The relay time is 1-99 seconds. 2. Delete a PIN 2 (User ID) # Delete Card by User ID 1. Enter Program Mode by press: *(Master Code) #.
OR (1 is 50mS.) Default is 5 seconds. ACCESS CONFIGURATION: CARD OR PIN & CARD ONLY ----------- Deletes the User ID number and PINS can be deleted continuously. Deleting by ID number will clear cards and PINS 2. Press 20000 #
Add User Cards associated PIN 3. Exit:
2. Latch Mode 4 0 # Programming Step Keystroke Combination All configuration data is retained.
3. Exit
Sets the relay to ON/OFF Latch Programming Step Keystroke Combination 1. Enter Program Mode (Master Code) #
mode 1. Enter Program Mode (Master Code) # Reset Strike-Out Alarm
2. Delete User Card by User ID 2 (User ID) #
3. Exit Enter Master Code or Valid Card/PIN to silence
3. Exit Program Mode