220V Main DCDB - 8FA

This document provides a layout of circuit breakers and equipment for a 220V Main DCDB board, listing the equipment and ratings for each of the 15 slots. It details things like DC voltage metering and protection, bus couplers, chargers, unit switchgears, turbine and diesel generator control panels, customer loads, and spare circuits. The board controls and protects various critical power distribution and control equipment for a facility.

Uploaded by

Joydev Ganguly
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as DOC, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
97 views2 pages

220V Main DCDB - 8FA

This document provides a layout of circuit breakers and equipment for a 220V Main DCDB board, listing the equipment and ratings for each of the 15 slots. It details things like DC voltage metering and protection, bus couplers, chargers, unit switchgears, turbine and diesel generator control panels, customer loads, and spare circuits. The board controls and protects various critical power distribution and control equipment for a facility.

Uploaded by

Joydev Ganguly
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as DOC, PDF, TXT or read online on Scribd
You are on page 1/ 2

220V Main DCDB – 8FA [1000A, 220VDC]

1F 2F 3F 4F 5F 6F 7F 8F 9F 10F 11F 12F 13F 14F 15F


Empty Empty Empty Empty Empty DC volt. I/C 1 Bus I/C 2 DC volt Empty Empty Empty Empty EOP 1
metering from coupler from metering starter
& prot. FCB DC- BC FCB & prot. panel –
Bus PT – Charge – 1000A Charger Bus PT – S 97A
S - 6A r– – 1000A - 6A
1000A
Spare Spare – Unit Misc. HFO rtn. Spare - 6.6KV Spare Acoustic HFO trip vlv Spare – FSSS
-20A 3.7KW / PMCC Use – line trip 0.01KW Unit Swgr -20A Encl SV - 0.01KW 5.3KW / Panel –
7.3 A 8DA – 32A vlv- /0.02A (8CA) – lighting /0.02A 10A 32A
20A 0.01KW 20A DC – 14A
/0.02A
Custome 6.6KV Turbine TG Panel Solenoid Spare - 6.6KV Power DAVR – Scanner Spare - DG PCC
r Loads - Unit Swgr MCC – 5A vlv for 0.02KW Unit Swgr House 15A Emg Air 0.02KW 8DG –
6A (8CA) – 8KA – CEP /0.04A (8CB) – A/C damper SV - /0.04A 20A
20A 20A disch. 20A MCC#O 0.01KW
vent - TA – /0.02A
0.02KW 20A
/0.04A
Solenoid 6.6KV BLR MCC GCD – 5A SV of Spare 220V Fuse GT#8M 220V Fuse Solenoid vlv Spare – Spare -
vlv of RC Unit Swgr 8HA – vac. bkr- -50A DCDB – B - 6A DCDB – of RC vlv 6A 0.02KW
vlv (8CB) – 20A 0.02KW 50A – ESP 32A -0.02KW /0.04A
-0.02KW 20A /0.04A DCDB /0.04A
/0.04A
Spare Solenoid DG PCC GCD – 5A RH/SH DC SOP Misc. Use EMG Misc. Use Solenoid vlv Spare – Misc.
-32A vlv for 8DG – block vlv starter – 32A MCC – 32A of RC vlv 10A Use –
CEP 20A – SV panel – 8EA – -0.02KW 5.3KW /
disch. 0.02KW 60A 20A /0.04A 10A
vent - /0.04A
0.02KW /
0.04A
GT#8MB RH/SH EMG Custome Misc. Empty Empty ESP PCC GCD – 5A Sol. vlv for Spare – Spare –
- 6A Ctrl vlv - MCC 8EA r Loads - Use – 8DB – CEP disch. 15A 60A
0.02KW / – 20A 6A 63A 20A vent
0.04A
Gen Prot Power Spare – UAT Spare – ESP PCC GCD – 5A RH/SH Spare – Empty
panel - House 6A 8AMB – 63A 8DC – block vlv – 16A
16A A/C 6A 20A SV
MCC#OT 0.02KW
A /0.04A
220V 220V Spare – 6.6KV Empty 220V Customer Misc. Use – Spare –
Fuse Fuse 16A Stn. Swgr Fuse Loads - 6A 25A 20A
DCDB – DCDB – (OCB) – DCDB –
50A 50A 20A 50A
Empty Empty Empty Empty