TEST REPORT
EN 60335-2-102 / EN 60335-2-6
Safety of household and similar electrical appliances
Part 2-102: Particular requirements for gas, oil and solid-fuel burning appliances
having electrical connections
Part 2-6: Particular requirements for stationary cooking ranges, hobs, ovens and
similar appliances
Reference number: 198155TRFSAF
E.U.T.: Built in hobs
Mod : 6822 (see page 5 for speaking code)
Safety -- T E S T R E P O R T
2011-11-20
Test Report No. : 198155TRFSAF ______________________________________________________________________________________________
Date of issue
General Comments
The CE marked component has been declared by its manufacturer in conformity with the applicable
national legislation and it is given the presumption to satisfy the standard listed in table 24.1.
It is responsibility of product manufacturer to verify conformity of the component with a.m. standard.
Certificates/CE conformity declarations/manufacturers declarations of listed components shall be
included in the TCF of the product.
Summary of testing:
This appliance is a cooking appliance built in hobs designed and built for domestic use.
It is composed by 0 or 1 or 2 electric hobs and 2 or 3 or 4 gas cooking zone.
All of variants equipped with ignition module.
Different models changes for the dimension enclosure and for the functions. Model 6822 is the most complex
and the other models are the same as 6822 without some components.
6 CLASSIFICATION -
6.1 Protection against electric shock: Class I P
Class I, II, III (IEC 60335-2-6 : 2002):
6.2 Protection against harmful ingress of water P
7.8 Except for type Z attachment, terminals for connection to the supply mains indicated as -
follows:
- marking of terminals exclusively for the neutral P
conductor (N)
- marking of protective earthing terminals (symbol P
5019 of IEC 60417)
- marking not placed on removable parts P
7.9 Marking or placing of switches which may cause a P
hazard
7.10 Indications of switches on stationary appliances and P
controls on all appliances by use of figures, letters or
other visual means ................................................... :
The figure 0 indicates only OFF position, unless no N
confusion with the OFF position
The figure 0 indicates OFF position and figure I N
indicates ON position of touch controls for hobs or
(IEC 60335-2-6:2002)
for each hob element (IEC 60335-2-6:2002) P
7.11 Indication for direction of adjustment of controls P
7.12 Instructions for safe use provided P
Instructions shall include the following: (IEC 60335-2-6:2002)
Warning: If the surface is cracked, switch off the N
appliance to avoid the possibility of electric shock, for
hob surfaces of glass-ceramic or similar material
which protect live parts
During use the appliances becomes hot. Care N
should be taken to avoid touching heating elements
inside the oven, for cooking ranges and ovens
Instructions for ovens: (IEC 60335-2-6:2002) -
Warning: Accessible parts may become hot during N
use. Young children should be kept away.
Instructions for ovens having doors with glass panels: (IEC 60335-2-6:2002) -
Do not use harsh abrasive cleaners or sharp metal N
scrapers to clean the oven door glass since they can
scratch the surface, which may result in shattering of
the glass.
- built-in appliances P
- fixed appliances P
- appliances delivered in separate units N
8.2 Class II appliances and constructions constructed so N
that there is adequate protection against accidental
contact with basic insulation and metal parts
separated from live parts by basic insulation only
Only possible to touch parts separated from live parts N
by double or reinforced insulation
11 HEATING
11.1 No excessive temperatures in normal use P
For cooking ranges and ovens, compliance is also P
checked by the test of 11.101 (IEC 60335-2-6:2002)
11.2 Placing and mounting of appliance as described -
- built-in (IEC 60335-2-6:2002) P
- against a wall (IEC 60335-2-6:2002) N
- on the floor (IEC 60335-2-6:2002) N
For hobs, the tests are carried out with a vessel filled P
as specified in 3.1.9.101 placed on each cooking
zone (IEC 60335-2-6:2002)
Induction hob elements and induction wok elements N
are tested as specified for motor-operated
appliances (IEC 60335-2-6:2002)
13.2 Leakage current measured by means of the circuit P
described in figure 4 of IEC 60990
Leakage current measurements (see appended table) P
13.3 The appliance is disconnected from the supply P
Electric strength tests according to table 4 (see appended table) P
No breakdown during the tests P
14 TRANSIENT OVERVOLTAGES -
Appliances withstand the transient overvoltages to N
which they may be subjected
Clearances having a value less than specified in table N
16 subjected to an impulse voltage test, the test
voltage specified in table 6
No flashover during the test, unless of functional N
insulation
In case of flashover of functional insulation, the N
appliance complies with clause 19 with the clearance
short circuited
15 MOISTURE RESISTANCE -
15.1 Enclosure provides the degree of moisture protection IPX0 N
according to classification of the appliance
Compliance checked as specified in 15.1.1, taking into N
account 15.1.2, followed by the electric strength test of
16.3
No trace of water on insulation which can result in a N
reduction of clearances and creepage distances below
values specified in clause 29
15.1.1 Appliances, other than IPX0, subjected to tests as N
specified in IEC 60529 ............................................. :
19 ABNORMAL OPERATION -
19.1 The risk of fire or mechanical damage under P
abnormal or careless operation obviated
Electronic circuits so designed and applied that a N
fault will not render the appliance unsafe
For induction hobs compliance is also checked by N
the test 19.101and 19.102 (19.4 not applicable)
(IEC 60335-2-6:2002)
19.101 is not applicable to induction wok elements N
(IEC 60335-2-6:2002)
Temperature-sensing probes placed in the oven in N
any position likely to occur during normal use that
they are connected to control the oven temperature
(IEC 60335-2-6:2002)
19.2 Test of appliance with heating elements with 0.85x3500Wx(220/230)² = P
restricted heat dissipation; test voltage (V): power 2722W (195V)
input of 0.85 times rated power input
Hob elements are operated without a vessel, pan P
detectors being rendered inoperative.
Oven doors are open or closed, whichever is more
unfavourable.
Hob lids are closed unless the hob elements are
interlocked with the lid or an indicator lamp shows
that a hob element is switched on. (IEC 60335-2-
6:2002)
For appliances incorporating more than one heating P
unit, the test is only carried with the heating unit
resulting in the most unfavourable conditions, its
control adjusted to the highest setting.
For appliance incorporate an oven without an
indicator lamp to show that the oven is switched on,
the oven is operated, its control adjusted to the
highest setting. (IEC 60335-2-6:2002)
For induction hob element or induction wok element N
with a metallic lid: a force of 30N is applied to the
closed lid in the most unfavourable place by means
of test probe B of IEC 61032. (IEC 60335-2-6:2002)
Pyrolytic self-cleaning ovens are also operated N
under cleaning conditions, motors which operate
during cleaning being switched off or disconnect in
turn. (IEC 60335-2-6:2002)
21 MECHANICAL STRENGTH -
21.1 Appliance has adequate mechanical strength and is P
constructed as to withstand rough handling
22 CONSTRUCTION -
22.1 Appliance marked with the first numeral of the IP N
system, relevant requirements of IEC 60529 are
fulfilled
22.2 Stationary appliance: means to provide all-pole disconnection from the supply -
provided, the following means being available:
- a supply cord fitted with a plug P
- a switch complying with 24.3 N
- a statement in the instruction sheet that a N
disconnection incorporated in the fixed wiring is to be
provided
- an appliance inlet N
Singe-pole switches and single-pole protective P
devices for the disconnection of heating elements in
single-phase, permanently connected class 01 and
class I appliances, connected to the phase conductor
22.3 Appliance provided with pins: no undue strain on N
socket-outlets
Applied torque not exceeding 0.25 Nm N
23 INTERNAL WIRING -
24 COMPONENTS -
24.1 Components comply with safety requirements in P
relevant IEC standards
List of components (see appended table) P
Components not tested and found to comply with N
relevant IEC standard for the number of cycles
specified are tested in accordance with 24.1.1 to
24.1.9
Components not tested and found to comply with P
relevant IEC standard, components not marked or
not used in accordance with its marking, tested under
the conditions occurring in the appliance
Lampholders and starterholders not being tested and N
found to comply with the relevant IEC standard,
tested as a part of the appliance and additionally
according to the gauging and interchangeability
requirements of the relevant IEC standard
24.1.1 Capacitors likely to be permanently subjected to the N
supply voltage and used for radio interference
suppression or for voltage dividing, complying with
IEC 60384-14, or
tested according to annex F N
24.1.2 Safety isolating transformers complying with IEC N
61558-2-6, or
- during installation N
At least two screws being used for each connection N
providing earthing continuity, unless
the screw forms a thread having a length of at least N
half the diameter of the screw
Thread-cutting and space-threaded screws may be N
used in connections providing earthing continuity,
provided unnecessary to disturb the connection and
at least two screws are used for each connection
28.4 Screws and nuts that make mechanical connection P
secured against loosening if they also make electrical
connections or connections providing earthing
continuity
Rivets for electrical connections or connections N
providing earthing continuity secured against
loosening if subjected to torsion
31 RESISTANCE TO RUSTING -
A ANNEX A (INFORMATIVE) -
ROUTINE TESTS
Description of routine tests to be carried out by the P
manufacturer
B ANNEX B (NORMATIVE) -
APPLIANCES POWERED BY RECHARGEABLE BATTERIES
The following modifications to this standard are N
applicable for appliances powered by batteries that
are recharged in the appliance
This annex does not apply to battery chargers N
3.1.9 Appliance operated under the following conditions:
-the appliance, supplied by its fully charged battery, N
operated as specified in relevant part 2
-the battery is charged, the battery being initially N
discharged to such an extent that the appliance
cannot operate
-if possible, the appliance is supplied from the supply N
mains through its battery charger, the battery being
initially discharged to such an extent that the
appliance cannot operate. The appliance is operated
as specified in relevant part 2
C ANNEX C (NORMATIVE) -
AGEING TEST ON MOTORS
Tests, as described, carried out when doubt with N
regard to the temperature classification of the
insulation of a motor winding
D ANNEX D (NORMATIVE) -
THERMAL MOTOR PROTECTORS
Applicable to appliances having motors that N
incorporate thermal motor protectors
E ANNEX E (NORMATIVE) -
NEEDLE-FLAME TEST
Needle-flame test carried out in accordance with P
IEC 60695-11-5, with the following modifications:
7 Severities -
F ANNEX F (NORMATIVE) -
CAPACITORS
Capacitors likely to be permanently subjected to the N
supply voltage, and used for radio interference
suppression or voltage dividing, comply with the
following clauses of IEC 60384-14, with the following
modifications:
1.5 Terminology -
1.5.3 Class X capacitors tested according to subclass X2 N
1.5.4 This subclause is applicable N
1.6 Marking -
Items a) and b) are applicable N
3.4 Approval testing -
3.4.3.2 Table II is applicable as described N
4.1 Visual examination and check of dimensions -
G ANNEX G (NORMATIVE) -
SAFETY ISOLATING TRANSFORMERS
The following modifications to this standard are N
applicable for safety isolating transformers:
7 Marking and instructions -
7.1 Transformers for specific use marked with: -
H ANNEX H (NORMATIVE) -
SWITCHES
Switches comply with the following clauses of IEC 61058-1, as modified: -
-The tests of IEC 61058-1 carried out under the N
conditions occurring in the appliance
-Before being tested, switches are operated 20 times N
without load
8 Marking and documentation -
Switches are not required to be marked N
However, switches that can be tested separately N
from the appliance marked with the manufacturer’s
name or trade mark and the type reference
13 Mechanism -
The tests may be carried out on a separate sample N
15 Insulation resistance and dielectric strength -
15.1 Not applicable N
15.2 Not applicable N
15.3 Applicable for full disconnection and micro- N
disconnection
17 Endurance -
Compliance is checked on three separate appliances N
or switches
For 17.2.4.4, the number of cycles is 10 000, unless N
otherwise specified in 24.1.3 of the relevant part 2 of
IEC 60335
Switches for operation under no load and which can N
be operated only by a tool and switches operated by
hand that are interlocked so that they cannot be
operated under load, are not subjected to the tests
Subclauses 17.2.2 and 17.2.5.2 not applicable N
The ambient temperature during the test is that N
occurring in the appliance during the test of Clause
11 in IEC 60335-1
Temperature rise of the terminals not more than 30 K N
above the temperature rise measured in clause 11 of
IEC 60335-1
20 Clearances, creepage distances, solid insulation and coatings of rigid printed board -
assemblies
This clause is applicable to clearances and creepage N
distances for functional insulation, across full
disconnection and micro-disconnection, as stated in
table 24
I ANNEX I (NORMATIVE) -
MOTORS HAVING BASIC INSULATION THAT IS INADEQUATE FOR THE RATED
VOLTAGE OF THE APPLIANCE
The following modifications to this standard are N
applicable for motors having basic insulation that is
inadequate for the rated voltage of the appliance:
8 Protection against access to live parts -
8.1 Metal parts of the motor are considered to be bare N
live parts
11 Heating -
J ANNEX J (NORMATIVE) -
COATED PRINTED CIRCUIT BOARDS
Testing of protective coatings of printed circuit boards N
carried out in accordance with IEC 60664-3 with the
following modifications:
5.7 Conditioning of the test specimens -
K ANNEX K (NORMATIVE) -
OVERVOLTAGE CATEGORIES
The information on overvoltage categories is P
extracted from IEC 60664-1
Overvoltage category is a numeral defining a P
transient overvoltage condition
Equipment of overvoltage category IV is for use at N
the origin of the installation
Equipment of overvoltage category III is equipment in N
fixed installations and for cases where the reliability
and the availability of the equipment is subject to
special requirements
Equipment of overvoltage category II is energy P
consuming equipment to be supplied from the fixed
installation
If such equipment is subjected to special N
requirements with regard to reliability and availability,
overvoltage category III applies
Equipment of overvoltage category I is equipment for N
connection to circuits in which measures are taken to
limit transient overvoltages to an appropriate low level
L ANNEX L (INFORMATIVE) -
GUIDANCE FOR THE MEASUREMENT OF CLEARANCES AND CREEPAGE
DISTANCES
M ANNEX M (NORMATIVE) -
POLLUTION DEGREE
The information on pollution degrees is extracted P
from IEC 60664-1
Pollution -
The microenvironment determines the effect of N
pollution on the insulation, taking into account the
microenvironment
Means may be provided to reduce pollution at the N
insulation by effective enclosures or similar
Minimum clearances specified where pollution may N
be present in the microenvironment
Degrees of pollution in the microenvironment -
For evaluating creepage distances, the following degrees of pollution in the -
microenvironment are established:
- pollution degree 1: no pollution or only dry, non- N
conductive pollution occurs. The pollution has no
influence
- pollution degree 2: only non-conductive pollution N
occurs, except that occasionally a temporary
conductivity caused by condensation is to be
expected
- pollution degree 3: conductive pollution occurs or P
dry non-conductive pollution occurs that becomes
conductive due to condensation that is to be
expected
- pollution degree 4: the pollution generates N
persistent conductivity caused by conductive dust or
by rain or snow
N ANNEX N (NORMATIVE) -
PROOF TRACKING TEST
O ANNEX O (INFORMATIVE) -
SELECTION AND SEQUENCE OF THE TESTS OF CLAUSE 30
Description of tests for determination of resistance to P
heat and fire
P ANNEX P (INFORMATIVE) -
GUIDANCE FOR THE APPLICATION OF THIS STANDARD TO APPLIANCES
USED IN WARM DAMP EQUABLE CLIMATES
Modifications applicable for class 0 and 01 appliances having a rated voltage -
exceeding 150V, intended to be used in countries having a warm damp equable
climate and that are marked WDaE
Modifications may also be applied to class 1 appliances having a rated voltage -
exceeding 150V, intended to be used in countries having a warm damp equable
climate and that are marked WdaE, if liable to be connected to a supply mains that
excludes the protective earthing conductor
5 General conditions for the tests -
Q ANNEX Q (INFORMATIVE) -
SEQUENCE OF TESTS FOR THE EVALUATION OF ELECTRONIC CIRCUITS
Description of tests for appliances incorporating electronic circuits N
R ANNEX R (NORMATIVE) -
SOFTWARE EVALUATION
Software evaluated in accordance with the following clauses of Annex H of IEC 60730- N
1, as modified
H.2 Definitions -
Only definitions H.2.16 to H.2.20 applicable N
H.7 Information -
Only footnotes 12) to 18) of Table 7.2, as modified, N
applicable
H.11.12 Controls using software -
All the subclauses of H.11.12, as modified, except N
H.11.12.6 and H.11.12.6.1, applicable
H.11.12.7 Delete text N
H.11.12.7.1 For appliances using software class C having a N
single channel with self-test and monitoring structure,
the manufacturer provides the measures necessary
to address the fault/errors in safety related segments
and data
H.11.12.8 Software fault/error detection occurs before N
compliance with 19.13 of IEC 60335-1 is impaired
H.11.12.8.1 Replace text N
H.11.12.13 Software and safety related hardware under its N
control initializes and terminates before compliance
with 19.13 of IEC 60335-1 is impaired
~
10.2 TABLE: Current deviation P
Current deviation of/at: I rated (A) I measured (A) dI Required dI Remark
at 230V 15.2 15.9
11.101 TABLE: Temperature rise limits for accessible front and side surfaces P
dT (K) Max. dT (K)
Front surfaces of oven doors
Test step n. - - - - - -
Ambient (°C) - - - - - -
Metal and painted metal - - - - - - 45
Vitreous-enamelled metal - - - - - - 50
Glass and ceramic - - - - - - 60
Plastic having a thickness exceeding 0,3mm - - - - - - 80
Other accessible front and side surfaces
(or surfaces above 850 mm)
Test step n. 1 - - - - -
Ambient (°C) 25 - - - - -
Metal and painted metal 20 - - - - - 60
Vitreous-enamelled metal - - - - - - 65
Glass and ceramic - - - - - - 80
Plastic having a thickness exceeding 0,3mm 10 - - - - - 100
19.7 and TABLE: abnormal operation, temperature and temperature rise measurements P
19.13
at 0,85 times rated for test step n.: 1 (19.2) heating hob
at 1,15 times rated for test step n.: 2 (19.4) heating hob
3 (19.5) heating hob
at 1,24 times rated for test step n.: 4 (19.3) heating hob
at voltage input (V) for test step n.:
Part measured Max. dT (K) Measured (K)
Test step n. --- 1 2 3 4
Ambient (°C) 25 25 25 25
Wall-ceiling and floor of test corner 150 67 116 67 93
Terminal block 150 43 91 49 60
Power cord 150 17 27 14 22
Manufacturer/ Mark(s) of
Object / part No. Type / model Technical data Standard
trademark conformity
Terminal block NOVA SL100 16A 400 V T125 EN 60998-1 VDE
Terminal block
GP BGTB16A 450V, 16A, T110 EN 60335-2-6 CTS
(alternative)
Tested in
Signal Lamp AR-EL SL-400 250V AC T120 EN 60335-2-6
appliance VDE
Signal Lamp S01-S10-S16- Tested in
AN-EL 240V AC T120 EN 60335-2-6
(alternative) S13-S19-S20 appliance VDE
Signal Lamp
Başoğlu HB9 240V AC T120 EN 60335-2-6 VDE
(alternative)
EN 60335-2-6 EN Test in the
Internal wiring STAR N2GFAF 300V, T180
60335-1 appliance, VDE
Internal wiring EN 60335-2-6 EN Test in the
ELCAB N2GFAF 300V, T180
(alternative) 60335-1 appliance, VDE
Hob heating 22375315072 2000W Test in the
ŞANAL EN 60335-2-6
element 111 230V appliance TUV
Hob heating 135W – 1500W
PĐRAMĐT 41* EN 60335-2-6 VDE
element(alternative) 100V - 240V
Hob heating HP180R-4
HOTDAC 2000W 230V EN 60335-2-6 NEMKO
element(alternative)
Hob heating GP.180.20.4.
GP 2000W 230V EN 60335-2-6 VDE
element(alternative) RH
Hob heating 22275315051 1500W Tested in
ŞANAL EN 60335-2-6
element 111 230V appliance TUV
Hob heating
HOTDAC HP145R-4 230V 1500W EN 60335-2-6 NEMKO
element(alternative)
Hob heating GP145.15.4.R
GP 230V 1500W EN 60335-2-6 VDE
element(alternative) H
Hob switch AN-EL RTH-D01 16A 250V T125 EN 61058-1 VDE
Hob switch
TIBON 430 250V T125 16A EN 61058-1 KEMA
(alternative)
Hob switch 230V/400V
MXT BC3 EN 61058-1 KEMA
(alternative) 10A/16A T150
Plug GMS G-20 16A 250V 2P+ IEC 60884 VDE
Plug (alternative) AREL 2002 16A 250V 2P+PE IEC 60884 KEMA
Plug (alternative) Deka 2PE02 16A 250V 2P+PE IEC 60884 VDE
Plug (alternative) Hedef TP501 16A 250V 2P+PE IEC 60884 VDE
Power cord GMS H05VV-F 3x1.5mm HD21 HAR
Power cord
Hedef H05VV-F 3x1.5mm HD21 HAR
(alternative)
220\240V 50-
Ignition device Erta ECB10-295 EN 61058 VDE
60Hz T120
Ignition device 220\240V 50-
GP 1814310 EN 61058 VDE
(Alternative) 60Hz T120
Ignition device 220\240V 50 EN 61058
Termal 507.XXX VDE
(Alternative) 60Hz
Ignition device 220\240V 50 EN 61058
Yangzhou DST2010-X.. VDE
(Alternative) 60Hz
Ignition device 220\240V 50 EN 61058
Castfatura IGB.... , IGS... VDE
(Alternative) 60Hz
>1250 and ≤1600 4,2 6,3 9,0 12,5 16,0 18,0 20,0
>1250 and ≤1600 4,2 6,3 9,0 12,5 16,0 18,0 20,0
>1250 and ≤1600 8,4 12,6 18,0 25,0 32,0 36,0 40,0
>1600 and ≤2000 5,6 8,0 11,0 16,0 20,0 22,0 25,0
>1600 and ≤2000 5,6 8,0 11,0 16,0 20,0 22,0 25,0
>1600 and ≤2000 11,2 16,0 22,0 32,0 40,0 44,0 50,0
>2000 and ≤2500 7,5 10,0 14,0 20,0 25, 0 28,0 32,0
>2000 and ≤2500 7,5 10,0 14,0 20,0 25, 0 28,0 32,0
>2000 and ≤2500 15,0 20,0 28,0 40,0 50,0 56,0 64,0
>2500 and ≤3200 10,0 12,5 18,0 25,0 32,0 36,0 40,0
>2500 and ≤3200 10,0 12,5 18,0 25,0 32,0 36,0 40,0
>2500 and ≤3200 20,0 25,0 36,0 50,0 64,0 72,0 80,0
>3200 and ≤4000 12,5 16,0 22,0 32,0 40,0 45,0 50,0
>3200 and ≤4000 12,5 16,0 22,0 32,0 40,0 45,0 50,0
>3200 and ≤4000 25,0 32,0 44,0 64,0 80,0 90,0 100,0
>4000 and ≤5000 16,0 20,0 28,0 40,0 50,0 56,0 63,0
>4000 and ≤5000 16,0 20,0 28,0 40,0 50,0 56,0 63,0
>4000 and ≤5000 32,0 40,0 56,0 80,0 100,0 112,0 126,0
>5000 and ≤6300 20,0 25,0 36,0 50,0 63,0 71,0 80,0
>5000 and ≤6300 20,0 25,0 36,0 50,0 63,0 71,0 80,0
>5000 and ≤6300 40,0 50,0 72,0 100,0 126,0 142,0 160,0
>6300 and ≤8000 25,0 32,0 45,0 63,0 80,0 90,0 100,0
>6300 and ≤8000 25,0 32,0 45,0 63,0 80,0 90,0 100,0
>6300 and ≤8000 50,0 64,0 90,0 126,0 160,0 180,0 200,0
>8000 and ≤10000 32,0 40,0 56,0 80,0 100,0 110,0 125,0
>8000 and ≤10000 32,0 40,0 56,0 80,0 100,0 110,0 125,0
>8000 and ≤10000 64,0 80,0 112,0 160,0 200,0 220,0 250,0
>10000 and ≤12500 40,0 50,0 71,0 100,0 125,0 140,0 160,0
>10000 and ≤12500 40,0 50,0 71,0 100,0 125,0 140,0 160,0
>10000 and ≤12500 80,0 100,0 142,0 200,0 250,0 280,0 320,0
)
* , B=Basic, S=Supplementary and R=Reinforced
Model/Type reference....................... :
Ratings ............................................. : 3500 W 220-240V~ 50 Hz
8.1.3 For appliances other than class II, use of test probe N
41 of IEC 61032: no contact with live parts of visible
glowing heating elements
8.1.4 Accessible part not considered live if: -
- safety extra-low a.c. voltage: peak value not N
exceeding 42.4 V
- safety extra-low d.c. voltage: not exceeding 42.4 V N
- or separated from live parts by protective N
impedance
If protective impedance: d.c. current not exceeding N
2 mA, and
a.c. peak value not exceeding 0.7 mA N
- for peak values over 42.4 V up to and including N
450 V, capacitance not exceeding 0,1 µF
- for peak values over 450 V up to and including N
15 kV, discharge not exceeding 45 µC
- for peak values over 15kV, the energy in the N
discharge not exceeding 350 mJ
8.1.5 Live parts protected at least by basic insulation before installation or assembly: -
- built-in appliances P
- fixed appliances N
- appliances delivered in separate units N
8.2 Class II appliances and constructions constructed so N
that there is adequate protection against accidental
contact with basic insulation and metal parts
separated from live parts by basic insulation only
Only possible to touch parts separated from live N
parts by double or reinforced insulation
8.101 Parts of spark-ignition circuit shall not be P
accessible if the limits in table 101 are exceeded,
unless they are piezoelectric igniters.
(IEC 60335-2-102/A1)
11 HEATING -
11.8 Temperature rises not exceeding values in table 3 (see appended tables) P
Sealing compound does not flow out P
Protective devices do not operate, except P
components in protective electronic circuits tested for N
the number of cycles specified in 24.1.4
The temperature rise of the walls of test corner are N
not measured. (IEC 60335-2-102)
The temperature rise limits for common parts of N
appliance having electric and fuel-burning heating
source are specified in the relevant part 2.
(IEC 60335-2-102)
15 MOISTURE RESISTANCE -
15.2 Spillage of liquid does not affect the electrical P
insulation
Appliances with type X attachment fitted with a N
flexible cord as described
Appliances incorporating an appliance inlet tested N
with or without an connector, whichever is most
unfavourable
Detachable parts removed N
Overfilling test with additional amount of P
water, over a period of 1 min (l)................................:
19.13 During the tests the appliance does not emit flames, P
molten metal, poisonous or ignitable gas in
hazardous amounts
Temperature rises not exceeding the values shown (see appended table) P
in table 9
Compliance with cl. 8 not impaired P
If the appliance can still be operated it complies with P
20.2
Insulation, other than of class III appliance, withstand the electric strength test of 16.3, -
the test voltage specified in table 4:
- basic insulation ...................................................... : 1000V P
- supplementary insulation ....................................... : N
- reinforced insulation............................................... : 3000V P
After operation or interruption of a control, N
clearances and creepage distances across the
functional insulation withstanding the electric
strength test of 16.3. the test voltage being twice the
working voltage
The appliance does not undergo a dangerous N
malfunction, and
no failure of protective electronic circuits, if the N
appliance is still operable
Appliances tested with an electronic switch in the off position, or in the stand-by
mode:
- do not become operational, or N
- if they become operational, do not result in a N
dangerous malfunction during or after the tests of
19.11.4
During the tests of 19.11.4, the appliance continue to N
operate normally (IEC 60335-2-102)
After the testes of 19.11.4 on gas and oil-burning N
appliances shall have reached a lock-out condition,
unless it continuous to operate normally.
(IEC 60335-2-102)
21 MECHANICAL STRENGTH -
21.1 Appliance has adequate mechanical strength and is P
constructed as to withstand rough handling
(IEC 60335-2-102)
22 CONSTRUCTION -
22.101 Parts of spark-ignition circuits shall be positioned or P
secured against loosening so that contact between
the circuit and other live parts is prevented.
(IEC/EN 60335-2-102)
22.102 If compliance with this standard can be affected by N
the polarity of the supply in the event of an earth
fault, the appliance shall incorporate a polarity-
detection device that results in shut-down or
prevents the appliance from operating if the polarity
is reversed. (IEC/EN 60335-2-102)
This requirement does not apply to appliances N
incorporating a control having all-pole
disconnection, to appliances intended to be
permanently connected to fixed wiring, or to
appliances having a supply cord fitted with a
polarized plug. (IEC/EN 60335-2-102)
22.103 If the limits in 8.101 are exceeded , the insulation of N
the parts of the circuit, where the distance to
unearthed accessible conductive parts do not
comply with reinforced insulation according to
29.1 and 29.2 (IEC/EN 60335-2-102/A1)
shall be resistant to ageing caused by partial N
discharge due to the ignition sparks .Unless the
insulation of cables having electrical properties
complying with ISO 3808
or the spark-ignition circuit are operated for at least N
100 h under the following test :
- Maximum duration of ignition switch-on repeated N
for the appropriate number of cycles in order to
obtained the total test time
- maximum value of the spark ignition voltage N
measured when the appliance is supplied at rated
voltage
- the temperature of the insulation as measured N
under conditions of Clause 11.
There shall be no breakdown of the insulation . N
In case of doubt the test of 16.3 is applied between
the cable conductor and water with cable insulation
immersed in water.
24 COMPONENTS -
24.101 Appliance outlets and plug connectors of N
interconnection cords shall not be
interchangeable if this could result in a hazard.
(IEC/EN 60335-2-102)
EN 62233
Clause Requirement + Test Result - Remark Verdict
EMF- ELECTROMAGNETICS FIELDS
The Tested product also complies to the requirements of EN 62233:2008
Limit ……………100% Measured max. :…2.0% P
24.1.7 If the remote operation of the appliance is via a telecommunication network, the N
relevant standards for the telecommunication interface circuitry in the appliance are
EN 41003 and EN 60950-1:2006, Subclause 6.3
25.6 Supply cords of single-phase portable appliances having a rated current not N
exceeding 16 A, fitted with a plug complying with the following standard sheets of
IEC 60083:1975:
- for Class I appliances: standard sheet C2b, C3b P
or C4 ....................................................................... :
- for Class II appliances: standard sheet C5 or C6 . : N
France
Norway
19.5 The test is also applicable to appliances intended to P
be permanently connected to fixed wiring
22.2 The second paragraph of this subclause, dealing P
with single-phase, permanently connected class I
appliances having heating elements, is not
applicable due to the supply system
25.6 Plugs according to standard sheet C3b not allowed P
Portugal
25.6 Plugs according to standard sheet C3b not allowed P
Spain
25.6 Plugs according to standard sheet C2b not allowed P
United Kingdom
25.6 Plugs according to standard sheet C2b not allowed P
ST
GROUP DIFFERENCES to IEC 60335-2-102 1 ed.
Clause Requirement – Test Result - Remark Verdict
8.101 Parts of spark-ignition circuit shall not be Continuous spark ignition with: P
accessible if the following limits are exceeded, - Discharge 9,5µAs per pulse
unless they are piezoelectric igniters: - duration: 0,35µs
Pulse spark ignition discharge = 100 µC per pulse - repetition: 0,45s
Continuous spark ignition
•Current = = 0,7 mA (peak)
•no load voltage = ≤10 kV
Or
•no load v
ltage = <10 kV(peak)
• Discharge = = ≤ 45 µC per pulse and
•frequen
y = 25 Hz
Pulse repetition ignition
• Di
charge = = ≤ 45 µC per pulse a
•pulse repetition 25 Hz
frequency
(EN 60335-2-102)
13.2 For appliances which are assembled on site, the N
leakage current and electrical strength tests on
the complete appliance need not be performed if
the components and sub-assemblies have been
separately tested and the interconnection is
carried out in accordance with the manufacturers
instructions. (EN 60335-2-102)
13.2 If the disconnection of protective impedance or N
radio interference filters is not possible, the limit
specified for leakage currents is to be calculated
taking into account the current through those
circuits or components. (EN 60335-2-102)
BB ANNEX AA (NORMATIVE) ——
Standards for control and safety devices
Standard use (EN 60335-2-102)
ANNEX EMF
The Tested product also complies to the requirements of EN 62233:2008
Limit ……………100% Measured max. :………2.0% P