Item Trade Category Specific/Area/ Description
No. Room/Gridline
Green, red indicator doorbell
chimes not working
1 E A
Main
entrance
2 E A All areas Emergency light battery pack
not yet installed
Convinience outlet no power
supply / expose wires for proper
harnessing / faceplate missing
3 E A
Walk in
closet
RCU panel for cleaning / no
4 E A
Walk in diagram / no panel directory /
closet door handle missing
5 E A Bedroom Minibar not yet installed
Convinience outlet no power
6 E B Bedroom supply / Faceplate cover missing /
with gap
Convinience outlet no power
7 E B Bedroom supply / expose wires
Covelight need to identify LED
8 E B Bedroom driver location and install tagging
Covelight need to identify LED
9 E A Bathroom driver location and install tagging
Telephone device not yet
10 E A Bathroom installed
11 E B Bathroom Expose wires
12 E A Bathroom Curtain covelight not
working
13 E A Bathroom Convinience outlet no
power supply
14 C A Bathroom Rectify finish cove with gap
15 M B Bed room Dirty air filter and fcu
noisy
16 M B Bed room Chilled pipe accessories not
installed properly
Photo Reference Closed-out signed off Remarks
Date
HCC FM
Item Trade Category Specific/Area/ Description
No. Room/Gridline
Chilled valve no
17 M B Bed room insulation cover
18 M B Bed room Chilled valve no
insulation cover
19 M B Bed room Actuator not insatall
Drain pan dirty and drain pan
20 M B Bed room backflow
Chilled pipe incomplate
insulation/note.drain pan hard to
access for maintenance need
manhole
21 M B Bed room
Pop-up rod to adust too high
conflict to vanity mirror
22 P A Bathroom
23 P A Toilet area Water closet no power and
water supply
24 P A bathroom Cleaned and remove
unwanted materials
25 A Shower area Calibration oh shower
mixer (TMV)
Refixed of pipe support for hot
26 E A Powder water manifold header
27 E
rectify and provide flexible
conduit on exposed wire
cleaned and remove construction
28 P A Toilet area debris on above ceiling perimeter
29 P A bathroom Washbasin no water supply
30 E B Bathroom Re-seal of hole and final paint
31 P A Bathroom pedestal box cover hard to
open/closed
32 C B
Walk in Rectify finish of access
closet manhole ceiling
33 C B
Walk in Rectify finish of paint on RCU
closet door
34 C B
Walk in Seal the gap around
closet smoke detector
35 C B Bedroom Final touch up of paint on door
frame
36 C B
Walk in Sliding door handle loose
closet
37 C B Bathroom Rectify finish under wash basin
38 C B Bathroom Rectify finish of wire gap of
telephone
Rectify finish of hinges gap at the
39 C B Bathroom back of vanity mirror
Rectify finish of hinges gap at the
40 C B Bathroom back of vanity mirror
Rectify finish of wire gap at the
41 C B Bathroom back of vanity mirror
Rectify finish of wire gap on
42 C B Bathroom curtain ceiling
Rectify finish of paint on
43 C B Bathroom ceiling
Calibration of the TMV (Thermostatic Mixing
44 P A Shower Room Valve) for the shower. Provide the calibration
certificate from the contractor.
TEAD (Toilet Exhaust Air Duct) not yet
45 M A Toilet Room
functional.
46 M A All Areas FAD (Fresh Air Duct) not yet
functional.
47 M A Vestibule No vibration isolator installed for the FCU.
Verify as per design.
48 O B All Areas Provide the approved T&C for the MEPF
system.
Photo Reference Closed-out signed off Remarks
Date
HCC FM
FM/BU/ODT/CM/Designer/Consultant/Contractor Representative(s):
Company Name Sign
Date
Item Trade Category Specific/Area/ Description Photo Reference
No. Room/Gridline
Legend:
Trade
C- Civil F - Fire Pro A - Arch'l B - BMS
S - Str'l P- Plumbing M - Mech'l/MVAC E - Electrical
Category
A - Major snag which may affect functionality and safety B - Minor snag which can be rectified after handover
Photo Reference Closed-out signed off Remarks
Date
HCC FM
O-
Others
L-
Landsc
ape
snag which can be rectified after handover