0% found this document useful (0 votes)
112 views6 pages

Pages From Curtain Wall (BD Submission) - 2

The document provides material properties and design parameters for a project involving the property development at Tai Wai Station. It specifies strengths and coefficients for welding, aluminum extrusions, tempered glass panels, and stainless steel bolts and screws. It also outlines permissible deflections for glass panels, structural members, and cantilevers. Standards and codes referenced include those for wind effects, structural steel and concrete use, aluminum structures, dead and imposed loads, and glazing. Analysis will utilize SAP2000 and STRAND7 computer programs.

Uploaded by

Con Can
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
112 views6 pages

Pages From Curtain Wall (BD Submission) - 2

The document provides material properties and design parameters for a project involving the property development at Tai Wai Station. It specifies strengths and coefficients for welding, aluminum extrusions, tempered glass panels, and stainless steel bolts and screws. It also outlines permissible deflections for glass panels, structural members, and cantilevers. Standards and codes referenced include those for wind effects, structural steel and concrete use, aluminum structures, dead and imposed loads, and glazing. Analysis will utilize SAP2000 and STRAND7 computer programs.

Uploaded by

Con Can
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 6

Project: Tai Wai Station Property Development

WAH 華東幕牆工程有限公司 in STTL No. 520


Wah Tung facade Company
T&N Limited
Prepared: Date: 19-Jul-18
Checked: File: Page: 2

2.2 Welding (H.K.Steel Code. - 2011, table 9.2a)

Welding strength 220 N/mm²

2.3 Aluminium Extrusion 6063-T5 (BS 8118)

Modulus of Elasticity 70000 N/mm²


Coefficient of Thermal Expansion 23.0x10-6 / ° C
G - Modulus of Rigidity 26600 N/mm²
0.2% proof stress / Minium Yield Strength ( Ys ) 110 N/mm²
Bending stregth 110 N/mm²
Shear strength 65 N/mm²

2.4 Aluminium Extrusion 6063-T6 (BS 8118)

Modulus of Elasticity 70000 N/mm²


Coefficient of Thermal Expansion 23.0x10-6 / ° C
G - Modulus of Rigidity 26600 N/mm²
0.2% proof stress / Minium Yield Strength ( Ys ) 160 N/mm²
Bending stregth 160 N/mm²
Shear strength 95 N/mm²

2.5 Aluminium Extrusion 6061-T6 (BS 8118)

Modulus of Elasticity 70000 N/mm²


Coefficient of Thermal Expansion 23.0x10-6 / ° C
G - Modulus of Rigidity 26600 N/mm²
0.2% proof stress / Minium Yield Strength ( Ys ) 240 N/mm²
Bending stregth 240 N/mm²
Shear strength 145 N/mm²

2.6 Aluminium panel 3003-H14 (BS 8118)

Modulus of Elasticity 70000 N/mm²


Coefficient of Thermal Expansion 23.0x10-6 / °C
0.2% proof stress / Minium Yield Strength ( Ys ) 125 N/mm²
Bending stregth 125 N/mm²

2.7 Tempered Glass panel

Modulus of Elasticity 70000 N/mm²


Allowable bending strength 50 N/mm²
Project: Tai Wai Station Property Development
WAH 華東幕牆工程有限公司 in STTL No. 520
Wah Tung facade Company
T&N Limited
Prepared: Date: 19-Jul-18
Checked: File: Page: 3
2.8 Class 70 stainless steel bolt / screw (BS EN 3506 part 1)

0.2% proof stress 450 N/mm²


Tensile strength 450 N/mm²
Shear strength 311 N/mm²
Bearing strength 828 N/mm²

3. PERMISSIBLE DEFLECTION

Glass panel Span / 60


Structural Member Span/180 or 20mm (Whichever is the lesser)
Structural Member (Cantilever) Span / 180

4. STANDARDS, CODES & PARTICULAR SPECIFICATIONS

Code of Practice on Wind Effects, Hong Kong - 2004


H.K. Steel Code 2011: Structural Use of Steel
H.K. Concrete Code 2004: Structural Use of Concrete
BS 8118: Part 1 1991, Structural Use of Aluminium
Code of Practice Dead and Imposed Loads 2011
BS 6262: Glazing for Buildings

5. COMPUTER PROGRAM
SAP2000 version 7.40 (standard)
B.D. ref S0473
(Valid till 2021 - 06 - 11)

STRAND7 version 2.4.6


BD ref. S0893
(Valid till 2020-02-19)
Project: Tai Wai Station Property Development
WAH 華東幕牆工程有限公司 in STTL No. 520
Wah Tung facade Company
T&N Limited
Prepared: Date: 19-Jul-18
Checked: File: Page: 4

2.0 Glass panel design

2.1 Check for 19mm thk. tempered glass panel (Refer to appendix A)
(Refer to drawing no. E03, detail 1)
2200
3825

Load case - WIND

Design wind pressure, P = 2.45kPa x 1.4


= 3.43 kPa

Load case - LIVE1 (3kN/m)

Live load, FL1 = 3kN/m x 2200 / 22 no. of shells


= 300.00 N/mm

Load case - LIVE2 (1.5kPa)

Live load, FL2 = 1.50 kPa

Load case - LIVE2 (1500N)

Live load, FL3 = 1500.0 N


Project: Tai Wai Station Property Development
WAH 華東幕牆工程有限公司 in STTL No. 520
Wah Tung facade Company
T&N Limited
Prepared: Date: 19-Jul-18
Checked: File: Page: 5

Joint no.
Project: Tai Wai Station Property Development
WAH 華東幕牆工程有限公司 in STTL No. 520
Wah Tung facade Company
T&N Limited
Prepared: Date: 19-Jul-18
Checked: File: Page: 6

Shell no.
Project: Tai Wai Station Property Development
WAH 華東幕牆工程有限公司 in STTL No. 520
Wah Tung facade Company
T&N Limited
Prepared: Date: 19-Jul-18
Checked: File: Page: 7

Shell section

You might also like