KLINGER® Graphite Laminate PSM
KLINGER® Graphite Laminate PSM is suitable for hot
water and steam at high temperatures up to 450°C.
Glueless gasket material consisting of expanded graphite and
a 0.1mm thick tanged stainless steel insert.
The material is free from resins, impregnations or other orga-
nic compounds. Therefore it is free of eventual toxic risks.
Stable physical properties over the whole temperature range.
Key features: Benefits:
»» Mechanically bonded tanged stainless steel insert »» Stable physical properties over the whole temperature range
»» Free of organic resins or toxic risks »» Provides excellent adaptability to any sealing surface
»» Excellent chemical resistance »» Very good tightness
»» Excellent high temperature resistance »» Suitable for steam up to 450°C
Certificates and approvals: Properties: referring to Graphite product range
»» DIN-DVGW
SUPERIOR
»» KTW
»» Fire Safe acc. to DIN EN ISO 10497 EXCELLENT
»» German Lloyd
»» BAM tested VERY GOOD
GOOD
MODERATE
MECHANICAL THERMAL SEALABILITY CHEMICAL
RESISTANCE RESISTANCE RESISTANCE
Industries:
INDUSTRY CHEMICAL OIL & GAS ENERGY INFRASTRUCTURE PULP & PAPER TRANSPORT FOOD & PHARMA
BEVERAGES
www.klinger.co.at
Typical technical data for KLINGER® Graphite Laminate PSM:
1.0 mm 1.5 mm 2.0 mm
Density of the graphite layer DIN 28090-2 g/cm 3
1.0 1.0 1.0
Purity of graphite 1)
DIN 51903 % ≥ 99.0 ≥ 99.0 ≥ 99.0
Metallic reinforcement Tanged metal 1.4401 (or 1.4404)
Thickness mm 0.10 0.10 0.10
Number of sheets 1 1 1
Compressibility ASTM F36 J ASTM F36 J % 25 - 35 30 - 40 35 - 45
Recovery ASTM F36 J ASTM F36 J % 15 - 20 15 - 20 12 - 18
Stress relaxation DIN 52913 16 h/ 50 MPa/ 300°C MPa ≥ 46 ≥ 46 ≥ 46
Klinger cold/hot compression 50 MPa Thickness decrease at 23°C % 30 - 40 35 - 45 35 - 45
Thickness decrease at 300°C % 1-3 1-3 1-3
Specific leakrate λ DIN 28090-2 mg/ s x m < 0.06 < 0.10 < 0.10
Chloride content of graphite layer 2)
DIN 28090-2 ppm ≤ 40 ≤ 40 ≤ 40
1) Nuclear quality with a purity of ≥99.8 available on request
2) Detailed specifications of the used graphite foils are found in our Graphite vade mecum, which will be sent to you on request with pleasure
Dimensions of the standard sheets:
Sizes: Tolerances:
1000 x 1000 mm, 1500 x 1500 mm, 2000 x 1000 mm Thickness 5%
Length 4 mm, width 4 mm
Thicknesses:
0.8 mm, 1.0 mm, 1.5 mm, 2.0 mm, 3.0 mm Other thicknesses, sizes and inserts on request.
pT diagram for thickness 2.0 mm:
200 1 2 3
3
180
In area one, the gasket In area two, the gasket In area three, do not in-
160 material is normally sui- material may be suitable stall the gasket without a
140 table subject to chemical but a technical evaluation technical evaluation.
120 compatibility. is recommended.
100 2
Always refer to the che-
mical resistance of the
80
gasket to the media.
60
40 1
pi bar
0
-200 -150 -100 -50 0°C 50 100 150 200 250 300 350 400 450
All information and recommendations contained in this data sheet are to the best of our knowledge correct. Since conditions of use are beyond our control,
users must satisfy themselves that the products are suitable for the intended processes and uses. No warranty is given or implied in respect of information or
recommendations or that any use of products will not infringe rights belonging to other parties. In any event or occurrence our liability
to our invoice value of the goods delivered by us to you. We reserve the right to change product design and properties without notice.
Certified acc. to DIN EN ISO 9001:2008 Subject to technical alterations. Status: June 2016
Rich. Klinger Dichtungstechnik GmbH & Co KG » Am Kanal 8-10 » A-2352 Gumpoldskirchen, Austria
Tel +43 (0) 2252/62599-137 » Fax +43 (0) 2252/62599-296 » e-mail: [email protected] www.klinger.co.at