RC Slab Punching Shear Stresses Check & Calculation of Required Shear Reinforcement According To Aci 318M-11 Using Usr From Ramconcept To Csi Safe Programs
RC Slab Punching Shear Stresses Check & Calculation of Required Shear Reinforcement According To Aci 318M-11 Using Usr From Ramconcept To Csi Safe Programs
0
318M-11 Using USR from RamConcept to CSI SAFE programs
Project :- Project Designed by:- M. Abu Shady
Building :- Building Checked by:- M. Abu Shady
Element:- Element Date:- 22-Sep-20
Location:- Location
1- General input:
Slab Thk t = 500 mm fy = 420 N/mm2
Clear cover = 35 mm fc' = 45 N/mm2
d = 455 mm fy stud= 345 N/mm2
Column Demensions Normal weight concrete λ = 1
c1 = 500 mm b_o= 1237 mm from RamConcept or CSI SAFE
c2 = 1000 mm Parallel to edge for edge column
Position Edge Column
ᵦ 2.00 ACI 11.11.2.1.a
αs 30 ACI 11.11.2.1.b
Unreinforced Stress Ratio from RamConcept or CSI SAFE USR=v_u/ 1.270 v_u= 2.11 MPa
(ϕv_c )=
Therefore, ϕv_c= 1.66 MPa Φvc < vu Use Shear reinforcement or drop panel
=
3- The maximum shear stress resistance provided by Concrete & shear reinforcement:
〖 ϕv 〗 _(n max) ={█(ϕ0.5√(f_c^′ ) with rebar shear reinforcement, ACI 318-11, Cl = 2.52 MPa APPLICABLE
11.11.3.2 @ϕ0.58√(f_c^′ ) with Steel I or C Shear heads, ACI 318-11, Cl 11.11.4.8
@ϕ0.66√(f_c^′ ) with Headed Shear stud "SSR", ACI 318-11, Cl 11.11.5.1 )} = 2.92 MPa APPLICABLE
= 3.32 MPa APPLICABLE
4- The maximum shear stress resistance provided by Concrete only in case of using shear reinforcement:
ϕv_(c with shear rft)={█(ϕ0.17√(f_c^′ ) with rebar shear reinforcement, ACI 318-11, Cl 11.11.3.2
@ϕ0.33√(f_c^′ ) with Steel I or C Shear heads, ACI 318-11, Cl 11.11.4.8 @ϕ0.25√(f_c^′ ) with = 0.86 MPa
Headed Shear stud "SSR", ACI 318-11, Cl 11.11.5.1 )} = 1.66 MPa
= 1.26 MPa
v_s=v_u-ϕv_(c with shear rft)= {█( for rebar shear reinforcement@ = 1.25 MPa
forSteel I or C Shear heads@ forHeaded Shear stud "SSR")} = 0.45 MPa
= 0.85 MPa
For one peripheral line use 4 Leg T12 @75mm =452 mm2 OK, Av actual > Av required
c- Determine distance a from sides of column where stirrups or studs may be terminated
a distance = 371 mm b_(o @ "Cut 3050mm v_(u @ "Cut 0.86 MPa
off" ) = off" )=