Lighting
CorePro LEDtube EM/
Mains T8
CorePro LEDtube 600mm 8W865
The CorePro LEDtube is an affordable LED solution suitable for replacing T8 fluorescent
lamps. The product provides a natural lighting effect for use in general lighting applications,
as well as instant energy savings – an environmentally friendly solution.
Product data
General Information Warm Up Time to 60% Light (Nom) 0.5 s
Cap-Base G13 [ Medium Bi-Pin Fluorescent] Power Factor (Nom) 0.9
Main Application Industrial Voltage (Nom) 220-240 V
Nominal Lifetime (Nom) 30000 h
Switching Cycle 200000X Temperature
B50L70 30000 h T-Ambient (Max) 45 °C
T-Ambient (Min) -20 °C
Light Technical T-Storage (Max) 65 °C
Color Code 865 [ CCT of 6500K] T-Storage (Min) -40 °C
Luminous Flux (Nom) 800 lm T-Case Maximum (Nom) 40 °C
Luminous Flux (Rated) (Nom) 800 lm
Correlated Color Temperature (Nom) 6500 K Controls and Dimming
Color Consistency <6 Dimmable No
Color Rendering Index (Nom) 80
LLMF At End Of Nominal Lifetime (Nom) 70 % Mechanical and Housing
Product Length 600 mm
Operating and Electrical
Input Frequency 50 to 60 Hz Approval and Application
Power (Rated) (Nom) 8W Energy Saving Product Yes
Lamp Current (Nom) 38 mA Energy Efficiency Label (EEL) A+
Starting Time (Nom) 0.5 s Approval Marks CE marking RoHS compliance KEMA Keur certificate
Datasheet, 2018, October 9 data subject to change
CorePro LEDtube EM/Mains T8
Energy Consumption kWh/1000 h 8 kWh Numerator - Quantity Per Pack 1
Numerator - Packs per outer box 10
Product Data Material Nr. (12NC) 929001338702
Full product code 871869671105700 Net Weight (Piece) 0.120 kg
Order product name CorePro LEDtube 600mm 8W865
EAN/UPC - Product 8718696711057
Order code 929001338702
Warnings and Safety
• NOTES: The overall energy efficiency and light distribution of any installation that uses these lamps are determined by the design of the
installation.
Dimensional drawing
A3 Product D1 D2 A1 A2 A3
CorePro LEDtube 600mm 8W865 25.7 mm 28 mm 588.5 mm 595.5 mm 602.5 mm
A2
A1
D1
D2
TLED 2ft 8-18W 800lm 6500K G13 Ess-Corep
Photometric data
General Uniform Lighting 150o 180o 150o
1 x TLED 8W 6500K 240D 9290013387
1 x 800 lm 200
Polaro intensityo diagramo Quantity estimation diagram UGR diagram
150 180 150 nr. of luminaires
16.0
200 hroom: 2.8 m hroom : 2.8 m
Reflectances: 0.70, 0.50, 0.20 22 Refl: 0.70 0.50 0.20
m
150
150 Maintenance factor: 1.0
120 25
Ceiling mounted
120o 120o Ceiling mounted
100
12.0 : viewed endwise
750 lx
50 90 Y : viewed crosswise
90o 90o Y : Parallel to viewing dir.
120 o 120o
500 lx
50 60
8.0 19
60o 100 60o 300 lx 22
30
150
100
γ
200 4.0
0
(cd/1000lm) 0o 10 30 50 70 90 (m2) 4.0 8.0 12.0 m 16.0
X
0-180o 90-270o
Utilisation factor table Luminance Table
Light output ratio 1.00
Service upward 0.27 Reflectances (%) for ceiling, walls and working plane (CIE) Plane 0.0 15.0 30.0 45.0 60.0 75.0 90.0
Room Cone
Service downward 0.73 0.80 0.80 0.70 0.70 0.70 0.70 0.50 0.50 0.30 0.30 0.00
45.0 5497 5452 5413 5442 5634 6191 7496
Index 0.50 0.50 0.50 0.50 0.50 0.30 0.30 0.10 0.30 0.10 0.00
50.0 5311 5251 5188 5171 5300 5785 7185
50
CIE flux code 36 64 85 73 100 k 0.30 0.10 0.30 0.20 0.10 0.10 0.10 0.10 0.10 0.10 0.00
55.0 5150 5083 4987 4919 4955 5348 6810
60.0 5020 4941 4827 4706 4643 4898 6399
UGRcen (4Hx8H, 0.25H) 23 0.60 0.40 0.38 0.38 0.37 0.36 0.29 0.27 0.22 0.25 0.21 0.17
0.80 0.50 0.47 0.47 0.46 0.44 0.37 0.34 0.29 0.31 0.27 0.22 65.0 4914 4838 4690 4513 4345 4426 5877
1.00 0.58 0.53 0.54 0.53 0.51 0.43 0.40 0.35 0.36 0.32 0.27 70.0 4839 4767 4594 4372 4104 3936 5245
1.25 0.65 0.60 0.62 0.59 0.57 0.50 0.46 0.41 0.42 0.38 0.31 75.0 4821 4743 4553 4304 3918 3448 4446
1.50 0.72 0.65 0.67 0.65 0.62 0.55 0.50 0.45 0.46 0.42 0.35 80.0 4840 4749 4577 4287 3803 2983 3280
2.00 0.81 0.72 0.76 0.72 0.69 0.63 0.57 0.53 0.52 0.49 0.41
85.0 4879 4767 4606 4332 3768 2656 1737
2.50 0.87 0.77 0.82 0.78 0.74 0.68 0.62 0.58 0.57 0.54 0.46
3.00 0.92 0.81 0.86 0.81 0.77 0.72 0.66 0.62 0.60 0.57 0.49 90.0 4958 4845 4672 4399 3866 2625 765
90o 90o
2
4.00 0.98 0.85 0.92 0.86 0.81 0.77 0.71 0.67 0.65 0.62 0.53 (cd/m )
5.00 1.02 0.88 0.96 0.90 0.84 0.80 0.74 0.71 0.68 0.65 0.56
Ceiling mounted
2017-03-02
50
60o 100 60o
150
200
(cd/1000lm) 0o
0-180o 90-270o
CalcuLuX Photometrics 4.5 Philips Lighting B.V. Page: 1/1
LEDtube 1500mm 20W G13 840 2200lm
Datasheet, 2018, October 9 2 data subject to change
CorePro LEDtube EM/Mains T8
Photometric data
100
Intensity (%)
80
60
40
20
0
200 300 400 500 600 700 800
[nm]
LEDtube HF 1500mm SO 25 W /865 T8
Lifetime
100 Lumen in % 100
Failure rate in %
80 95
90
60
85
40 80
20 75
0 70
0 10000 20000 30000 40000 50000
0 10000 20000 30000 40000 50000 60000
Time (hours) Burning hours
LEDtube 1500mm 20W G13 840 2200lm LEDtube 1500mm 20W G13 840 2200lm
© 2018 Philips Lighting Holding B.V. All rights reserved. Philips Lighting reserves the right to make changes in specifications
and/or to discontinue any product at any timewithout notice or obligation and will not be liable for any consequences resulting www.lighting.philips.com
from the use of this publication. 2018, October 9 - data subject to change