1722.3.4.1. 2 Storage: 1722.3.4.2.2 Installation
1722.3.4.1. 2 Storage: 1722.3.4.2.2 Installation
~ Series of 2018
DPWH Standard Specification on Item 1722 - Fence and Railings
Page 5 of 7
Precast plant box fence units shall be handled and transported in a manner to minimize
damage. Lifting devi~es or holes shall be consistent with industry standards. Lifting shall be
accomplished with methods or devices intended for this purpose as indicated on shop
drawings. Upon request, the precast concrete producer/ supplier shall provide documentation
on acceptable handling methods for the product.
1722.3.4.1. 2 Storage
Precast Plant Box Fence units shall be stored in a manner that will minimize potential damage.
1722.3.4.1.3 Delivery
Precast plant box fence units shall be delivered to the site in accordance with the delivery
schedule to avoid excessive build-up of units in storage at the site. Upon delivery to the jobsite
all precast concrete units shall be inspected by the Engineer for quality and final acceptance.
Upon final acceptance, the Engineer· shall acknowledge and understand the appropriate
methods for handling the accepted precast plant box fence unites). Upon acceptance by the
Engineer, the precast plant box fence manufacturer shall not be responsible for replacing
damaged product resulting from improper handling practices on the job site. The damaged
precast plant box fence unit shall be replaced by the Contractor at his own expense.
The general contractor shall be responsible for providing adequate access to the site to
facilitate hauling, storage and proper handling of the precast plant box fence units.
1722.3.4.2.2 Installation
Precast plant box fence units shall be installed to the lines and grades shown in the Plans.
Precast plant box fence units shall be lifted by suitable lifting devices at points provided by
the precast plant box fence producer/ supplier.
Precast plant box fence units shall be installed in accordance with applicable industry
standards or as directed by the Engineer. Upon request, the producer/ supplier of precast
plant box fence shall provide installation instructions.
Field modifications to the product shall relieve the precast producer/ supplier of liability
regardless if such modifications result in the failure of the precast plant box fence unit.
1722.3.4.2.3 Watertightness
Where watertightness is a necessary performance characteristic of the precast plant box fence
unit's end use, watertight joints, pipe-entry connectors and inserts should be used to ensure
the integrity of the entire system.
Department Order No. ~ Seriesof 2018
DPWHStandard Specification on Item 1722 - Fence and Railings
Page6 of 7
1722.3.5 Railings
••
Railings shall conform to the applicable requirements of Item 1051 - Railings.
The quantity to be paid for shall be the number of linear meters measured center to center of
posts of fencing erected in place and accepted.
The quantity, as determined in Section 1722.4, Method of Measurement, shall be paid for at
the contract price per unit of measurement respectively for each of the particular items listed
below and as shown in the Bid Schedule, which price and payment shall be full compensation
for furnishing and placing all materials and for all labor, equipment, tools and incidentals
necessary to complete the Item.
References:
1. DPWH Standard Specifications for Public Works 3. Site Furnishings Precast Concrete Planters
Structures, Volume III (Buildings, Ports and Unformatted Specifications
Harbors, Flood Control and Drainage Structure
and Water Supply Systems) 4. Specification for Construction & Installation for
a. Item 1046 - MasonryWorks Woodcrete® Rail PrecastConcrete Fence
b. Item 900 - Reinforced Concrete
c. Item 1051 - Railings 5. Specificationsfor PrecastWall System
CYCLONE WIRE!
STEEL MATTING
\
TUBULA.R PIPES
,s;;U'~<O !>ferA.o;a "
Cj~lA.AP'
ANGULA.R BAR
WELDED TO TUB.
1sro-- CYCLONE WIRE!
PIPES & CYCLONE
LS=
• STEEL MATTING
WIRES
TUBULA.R PIPES
G B (SOlJ'REO '<Eer AAGLUJI :;;;;C<.LVI
FIN. GRADE LINE
CONCRETE
PEDESTAL
~ CONCRETE ELEVATION
PLAN
PEDESTAL
WELDED WIRE FENCE
;- CONCRETE
HOLLOW BLOCK
RC COLUMN
(f)
w
a:
«
CONCRETE >
r:-- HOLLOW BLOCK
~, I / .. RC COLUMN
PLAN ELEVATION
CONCRETE HOLLOW BLOCK FENCE
PRECAST
3(100 r:- CONCRETE
WALL
RC COLUMN
PRECAST
CONCRETE
3000 WALL
/3-- RC COLUMN
FIN. GRADE LINE
PLAN ELEVATION
PRECAST CONCRETE FENCE
~-
PLAN
PRECAST PLANT BOX FENCE
----- --'(ABIES
--
ISOMETRIC VIEW ------