0% found this document useful (0 votes)
232 views1 page

Cable Structure Design Based On ASCE 19-10 & AASHTO 17th: Project: Client: Design By: Job No.: Date: Review by

This document provides an analysis and design summary for the cable structure of a main bridge span based on ASCE and AASHTO design codes. Key details include a main span of 4500 feet, a maximum cable sag of 450 feet, and a 60 degree angle for the anchor cable. The analysis checks that the sag to span ratio is satisfactory and calculates the parabolic curve of the main cable. It determines the maximum cable tension is less than the allowable tension capacity. Reactions on the tower top are also calculated.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLSX, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
232 views1 page

Cable Structure Design Based On ASCE 19-10 & AASHTO 17th: Project: Client: Design By: Job No.: Date: Review by

This document provides an analysis and design summary for the cable structure of a main bridge span based on ASCE and AASHTO design codes. Key details include a main span of 4500 feet, a maximum cable sag of 450 feet, and a 60 degree angle for the anchor cable. The analysis checks that the sag to span ratio is satisfactory and calculates the parabolic curve of the main cable. It determines the maximum cable tension is less than the allowable tension capacity. Reactions on the tower top are also calculated.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLSX, PDF, TXT or read online on Scribd
You are on page 1/ 1

PROJECT : PAGE :

CLIENT : DESIGN BY :
JOB NO. : DATE : REVIEW BY :
Cable Structure Design Based on ASCE 19-10 & AASHTO 17th

INPUT DATA
MAIN SPAN L= 4500 ft, (1371.60 m)
CABLE MAX SAG S= 450 ft, (137.16 m)

2-CABLE TOTAL LOAD ON STIFFENING DECK/GIRDER


w= 13.5 kips/ft, (197 kN/m), ASD level.
ANGLE OF ANCHOR CABLE
o
a= 60

CABLE TENSILE STRENGTH fsu* = fpu = 270 ksi, (1862 MPa)


SINGLE CABLE EFFECTIVE/NET AREA A= 800 in2 ( 516128 mm2 )

ANALYSIS & DESIGN SUMMARY


Check S/L= 1 / 10.0 < 1/9
> 1 / 12 [Satisfactory]
Parabolic Main Cable y = 4S/L2 x (L - x) = 8.88888888889E-05 x ( 4500 - x ) , control suspender (D - y) to keep parabolic curve.
Main Cable Curve Length = 4617.27 ft, (1407.34 m)

Maximum Main Cable Tension T = [ (0.5 w L)2 + (0.125 w L2/ S )2 ]0.5 = 81787.2 kips, (363789 kN), ASD level.
< 2 A fpu / Wt = 103473.1 kips, (460248 kN) [Satisfactory]
where Wt = 1.67 x 2.5 = 4.175 , AISC 360 & Reference page 907.

Reactions on Tower Top R = 0.5 w L + T Cos a = 71268.6 kips, (317003 kN), ASD level.
H = 0.125 w L2/ S - T Sin a = 5107.7 kips, (22719 kN), ASD level.

Reference: Engineers' Handbook for Bridge Design, China Communications Press, July 2007.