RIOHIT 600
RIOTRONIC G
XS
TM
Packaged Detonator
Electronic Sensitive
Seismic Detonator
Emulsion
TECHNICAL DATA SHEET DESCRIPTION
RIOTRONIC XS detonators are the most secure electronic
initiation systems for seismic exploration, made by MAXAM
Initiation Systems, reliable and rugged able to meet the most
demanding environments.
The RIOTRONIC XS system provides great time accuracy, safety in
use, and moreover presents higher versatility than other
conventional initiation systems.
The RIOTRONIC XS detonators are easily used without the need to
program them which gives a high level of flexibility and reduces
the time involved for the shot to enlarge the performance.
Its great precision permits to achieve highly satisfactory results,
reducing firing process time, improvement of performance,
enhancement of safety during the handling, and firing.
APPLICATION
RIOTRONIC XS has been designed to fire single or pattern
(multiple) shot points up to 20 at the same time.
RIOTRONIC XS is manufactured in a variety of duplex iron leg
wire to satisfy a wide range of seismic projects,
SHELF LIFE
RIOTRONIC XS up to 5 years under good storage conditions.
SAFETY
USE: It should be used, handled and stored with care, ensuring
the product is kept away from flames and excessive heat
sources.
RECOMMENDATIONS FOR USE
DISPOSAL: The disposal of explosive material can be
dangerous. Ensure that the appropriate safety measures have
To handle RIOTRONIC XS electronic detonator always follow the
been applied as per instructions on the SDS and in accordance
proper operation procedures.
with local regulations.
The RIOTRONIC XS electronic initiation system has been
designed to provide safety, secure and accurate initiation of
ADVANTAGES seismic energy source. The detonator always must be protected
from damage during priming and loading procedure.
• Safe, reliable and user friendly when handling. The RIOTRONIC XS detonators let user comply with security
• Safety against static electricity, stray currents: Only initiate regulation for total product tracking. (Traceability)
through a specific communication protocol.
• Easy to connect: Its Bus Line is non-polar, a Connector could For further information consult the User Recommendations Sheet
be included with the detonator to facilitate the connection included inside the boxes or packaging of the product and the
to the Fire Line. respective Safety Data Sheet (SDS).
• Every detonator is identified by a unique (ID) serial number,
which grants greater reliability, safety and security in its STORAGE
use.
• It also has the capacity of Scanning the line and permits to For safety and to maintain the explosive properties, RIOTRONIC
locate malfunctions and correct them before firing, such XS should be stored in authorized magazines, in a cool dry place,
as: Short-circuits in the lines and/or detonators. with good ventilation and stacked properly as designated on the
• Detection of missing connections. cases, may be stored at temperatures between - 40ºC and +70ºC.
• Check the operability of detonators.
• Designed to work under any environment
SLEEP TIME INSIDE BOREHOLES
• Water resistance. Perform consistently regardless of
hydrostatic pressure.
• Excellent water and abrasion resistant. RIOTRONIC XS can have a several months sleep time in dry
• Ideal for deep hole work and long sleep time. boreholes. If presence of water, the sleep time may be reduced to
• Better performance under static & dynamic pressure few weeks, depending on the depth and time.
www.maxamcorp.com TDS RIOTRONIC XS ENG N
RIOTRONIC XS
Technical Characteristic (Nominal Values)
Base charge: PETN 700 mg Shelf Life: 5 years Length Available: 4 - 40 m.
0 ms.
Resistence to
Primary charge: Lead azide 20 Kg. Delay Time: SUPPORTED
traction (crimp):
BY BOOM BOX 3
-40 ºC to + 71 ºC Resistence to 20 bar/30 days +/- 0.25ms
Operating Tolerance:
Hydrostatic (tested at 200m for
temperature: -40 ºF to 159,8 ºF
Pressure: 2 months)
RIOTRONIC XS
MAXAM Firing Interface: Shooter
25KV/2500 pF Electronic Circuit: RIOTRONIC
Iimmunity to (Pin to case)
Electrostatic Amount of
25 KV/2500 pF Iron 0,6 mm. simultaneous 20 dets.
Discharge (ESD): Line Tx:
(Pin to Pin) Duplex detonators:
Format and Packaging (Nominal Values)
Quantity
Length (*) Ø Line Net weight Gross weight
Coil color
(m) (mm) (Kg) (Kg)
Int. Total
4 0,6 25 250 13 15 Red
7,5 0,6 20 200 18 20 Red
11 0,6 10 100 13 15 Red
14 0,6 10 100 17 19 Red
Coils
17 0,6 8 80 16 18 Red
20 0,6 8 80 19 21 Red
23 0,6 6 60 16 18 Red
26 0,6 5 50 15 17 Red
15 0,6 60 120 19 21 Red
17 0,6 50 100 23 25 Red
20 0,6 40 80 21 23 Red
Reels
26 0,6 30 60 22 24 Red
30 0,6 30 60 23 25 Red
40 0,6 20 40 20 22.5 Red
* Other lenght under special requirement
Transport Classification Classification UN 0456, Class 1.4 S
SAFETY WARNING
Read the Instructions Safety Sheet and the Material Safety Data Sheet carefully before using RIOTRONIC. MAXAM strongly recommends not to use RIOTRONIC
products with detonators and/or initiation systems supplied by other manufacturers in the same blast and declines all liability in these cases.
RIOTRONIC must be stored at moderate temperatures in a dry and well ventilated place.
DISCLAIMER AND LIMITATION OF LIABILITY
The information contained herein (the “Information”) is not exhaustive and subject to periodic review. The data contained herein may vary on account of the
particular operating and maintenance conditions and of external factors, such as humidity, temperature, or pressure. MAXAM Europe, S.A. and/or its affiliates
(“MAXAM”) do not warrant or make any representation regarding the accuracy or completeness of the Information. MAXAM further reserves the right, in its
sole discretion and without prior written notice, to modify the products described herein (the “Products”) and/or their specifications.
The use of the Products is an intrinsically dangerous activity and must, consequently, be restricted to qualified and trained users in possession of any
necessary permits and licenses and comply at all times with appropriate safety and risk prevention measures and with applicable laws. The use, storage, or
handling, of the Products may be subject to local regulations and restrictions, which must be identified and adhered to by the user.
This document and any accompanying information (the “Documentation”) is not intended to constitute, and shall not be construed as, an offer or contractual
commitment on MAXAM’s side. MAXAM expressly disclaims any liability towards third parties with regard to the Documentation. For further information
about the Products, please contact your distributor or sales representative directly.
Distributor
Contact your local MAXAM
representative
for further information and for
obtaining a TDS in the local idiom
www.maxamcorp.com TDS RIOTRONIC XS ENG N