0% found this document useful (0 votes)
373 views11 pages

Mullion Calculation

The document contains material properties, geometry parameters, and load information for structural analysis of wall panels in multiple building prototypes. It provides masonry properties, stress limits, wall thickness, storey heights and applied loads for prototypes L2, L3, and L2A. Calculation results are presented for shear checks and bending stress checks of wall panels below and above lintel levels.

Uploaded by

Hunny Verma
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLSX, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
373 views11 pages

Mullion Calculation

The document contains material properties, geometry parameters, and load information for structural analysis of wall panels in multiple building prototypes. It provides masonry properties, stress limits, wall thickness, storey heights and applied loads for prototypes L2, L3, and L2A. Calculation results are presented for shear checks and bending stress checks of wall panels below and above lintel levels.

Uploaded by

Hunny Verma
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLSX, PDF, TXT or read online on Scribd
You are on page 1/ 11

Boundary condition of wall panel Free at top Pinned support at top

H/L α α
0.3 0.040 0.014
0.5 0.056 0.028
0.75 0.071 0.042
1 0.083 0.056
1.25 0.091 0.067
1.5 0.095 0.077
1.75 0.100 0.083

Wall panel type


Type 1
Type 2
Density of masonry unit 9
Ka 1
Kp 1
Ks 0.43
fb 0.5
Permissible vertical bending stress in
compression 0.215
fd (compressive stress due to DL) 0
Grade of Mortar M1
Basic compressive stress for masonry 0.5
Permissible tensile bending stress
for bending in horizontal direction
(MPa) 0.14
Permissible tensile bending stress
for bending in vertical direction
(MPa) 0.07
µ (orthogonality factor) 0.5
Prototype:L2
Storey ID Height Elevation Pd HM
TF 1.2 29.4 1.57 1.05
6F 3.6 25.8 1.52 3.45
5F 3.6 22.2 1.47 3.45
4F 4.5 17.7 1.42 4.35
3F 4.2 13.5 1.35 4.05
2F 4.2 9.3 1.26 4.05
1F 4.2 5.1 1.26 4.05
GF 5.1 0 1.26 4.95

Prototype:L3
Storey ID Height Elevation Pd HM
TF 3 18.90 1.99 2.85
3F 4.2 13.50 1.87 4.05
2F 4.2 9.30 1.75 4.05
1F 4.2 5.10 1.75 4.05
GF 5.1 0.00 1.75 4.95

Prototype:L2A
Storey ID Height Elevation Pd HM
TF 1.2 30 1.58 1.05
6F 3.6 26.4 1.53 3.45
5F 4.2 22.2 1.47 4.05
4F 4.5 17.7 1.42 4.35
3F 4.2 13.5 1.35 4.05
2F 4.2 9.3 1.26 4.05
1F 4.2 5.1 1.26 4.05
GF 5.1 0 1.26 4.95
Prototype:L2
Storey ID Height Elevation Pd Pdx Pdy HM
TF 1.2 7.2 1.19 1.07 1.43 1.05
1F 4.35 6 1.19 1.07 1.43 4.20
GF 6 0 1.19 1.07 1.43 5.55

Prototype:L3
Storey ID Height Elevation Pd Pdx Pdy HM
TF 1.2 7.20 1.19 1.43 1.07 1.05
1F 4.35 6.00 1.19 1.43 1.07 4.20
GF 6 0.00 1.19 1.43 1.07 5.55

Prototype:L2A
Storey ID Height Elevation Pd Pdx Pdy HM
TF 1.2 7.2 1.19 1.07 1.43 1.05
1F 4.35 6 1.19 1.07 1.43 4.20
GF 6 0 1.19 1.07 1.43 5.55
Type of
Height of Wall Type of Lintel Clear spacing
Building Name Storey ID Masonry
Mullion thickness wall level of Mullion (m)
unit

ALL BUILDINGS ALL STOREY 3.5 - 5.6 230 Type 1 Brick wall - 12.5
ALL BUILDINGS ALL STOREY 3.5 - 5.6 250 Type 1 AAC - 14
ALL BUILDINGS ALL STOREY 3.5 - 5.6 150 Type 1 AAC - 7
Connection detail
Mullion details
(Refer Detail A and Detail B of standard
(Refer standard drawing EDRC - C - STD - MU - NR - 0004)
drawing EDRC - STD - MU - NR - 0004))
Diameter of
Diameter of Shear
BM (m) DM (m) a b s1 Mechanical expansion dowel
sleeve anchor (Top
(Bottom connection)
connection)
200 230 Y12 - 2L-Y8 STPS @200 c/c 10 10
200 250 Y12 - 2L-Y8 STPS @200 c/c 10 10
200 150 Y10 - Y8 link @ 200 c/c 10 10
Panel Properties
Mullion Type
Lintel Maximum
Design wind Height of Wall Lintel
mullions HM (Design Continuous length of
S.No. pressure thickness level wall Lw
reference provided
(kN/m2) (m) (mm) (m)
table of (Yes/No) (m)
external wall)
1 1.26 5.55 250 Type 2 Yes 2.4 4
2 1.47 4.35 250 Type 1 No NA 3.2
3 1.47 4.35 250 Type 2 Yes 2.4 4.4
4 1.53 3.45 250 Type 1 No NA 3.2
Check for Shear Check for wall panel for Ty
Permissible Longitudinal Check for
Shear Force
τv shear stress Check for MH (kNm) bending flexure in
per meter V Mv (kNm)
fs (N/mm2) Shear stress longitudinal
(kN)
(N/mm2) direction
5.04 0.01008 0.1 OK NA NA NA NA
4.704 0.009408 0.1 OK 1.396945 0.134106764 OK 0.698473
6.468 0.012936 0.1 OK NA NA NA NA
4.896 0.009792 0.1 OK 1.342691 0.128898327 OK 0.671345
Check for wall panel for Type -1 Check
Check for Check for
Vertical Vertical Height of Longitudina
Self weight at tensile compressive
bending stress bending stress panel MH l bending
mid-height stress in stress in
(Tension) (Compression) above stress
(kN) vertical vertical
(N/mm2) (N/mm2) lintel, H1 (N/mm2)
direction direction
NA NA NA NA NA 3 1.44 -0.13824
4.89375 -0.0474783818 OK 0.08662838182 OK NA NA NA
NA NA NA NA NA 1.8 1.37984 -0.1324646
3.88125 -0.0489241636 OK 0.07997416364 OK NA NA NA
Check for wall panel above lintel level
Check for Check for
Check for Vertical Vertical Height of
Self weight tensile compressive
flexure in bending stress bending stress panel
Mv at mid- stress in stress in
longitudinal (Tension) (Compression) below
height vertical vertical
direction (N/mm2) (N/mm2) lintel, H2
direction direction
OK 0.72 3.375 -0.056 OK 0.0826 OK 2.4
NA NA NA NA NA NA NA NA
OK 0.68992 2.025 -0.058 OK 0.0743 OK 2.4
NA NA NA NA NA NA NA NA
Check for wall panel below lintel level
Longitudinal Check for Self Vertical Vertical
Check for tensile
MH bending flexure in weight at bending stress bending stress
Mv stress in vertical
stress longitudinal mid- (Tension) (Compression)
direction
(N/mm2) direction height (N/mm2) (N/mm2)
0.672 0.064512 OK 0.336 2.7 -0.021456 OK 0.043056
NA NA NA NA NA NA NA NA
0.8624 0.0827904 OK 0.4312 0.3 -0.0401952 OK 0.0425952
NA NA NA NA NA NA NA NA
Check for
compressive
stress in vertical
direction
OK
NA
OK
NA