FRACTAL KNOWLEDGE TRAINING SERVICES
CPD PROVIDER: Accreditation # 2017-030
Outline for Electrical Design Analysis
DPWH Memorandum Circular No. 02-2015,
DILG Memorandum Circular No. 23-2016,
PEC 2009, Article 1.2, p25, Art. 1.3.2.1(f) p.31
Continuing Development Program
Part Time
I. Introduction
- Welcome 0.5 hrs
- Objectives of the course
- Importance of DPWH Memorandum Circular No. 02-2015
- Importance of DILG Memorandum Circular No. 23-2016
- PEC 2 2009 : Art 1.2 and Art 1.3.2 (f)
II. Codes and Standards
- Discussion of PEC Chapter 2 ,Article 1.2 (Page 27) 0.5 hr
- Discussion of DPWH & DILG Memorandum Circulars
- The needs and reasons for Electrical Design Analysis
- Discussion , Q&A
III Design Analysis 1: Voltage Drop
- Objectives 2.5 hrs
- Importance of Voltage Drop in Design Analysis
- Standard on Acceptable Voltage Drop
- Requirement for Voltage Drop Calculation
- Computation of Wires and Cables Voltage Drop, Manual
- Computation of Wires and Cables Voltage Drop, MS Excel
- Template for presenting Voltage Drop Results : OBO Requirement
- Workshop1 : Residential Computation, Single phase
- Workshop2 : Industrial & Commercial Sample computation, 3 phase
- Skills Reinforcement
- Discussion , Q&A
IV Design Analysis 2: Faults Calculation Study
- Objectives 4.0 hrs
- Understanding the importance of Short Circuit Calculation
- Identifying the sources of Faults
- Use of Short Circuit Calculation Studies
- Preliminaries and requirements of Fault Calculation
- Impedance Computations for Cables, Motors, Transformers, Lump Loads
- Simplification of Impedance Diagram for SC calculation
- Calculation of Short Circuits , I3Ǿsc , IL-L, IL-G, IL-L-G, Manual
- Calculation of Short Circuits , I3Ǿsc , IL-L, IL-G, IL-L-G, MS Excel
FRACTAL KNOWLEDGE TRAINING SERVICES
Tel No. 02 - 904 - 2590 : Email :
[email protected] CPD PROVIDER: Accreditation # 2017-030
- Analysis of Short Circuits and kAIC sizing
- Template for presenting Voltage Drop Results : OBO Requirement
- Workshop1 : Hands-on Residential Computation
- Workshop2 : Hands-on Industrial & Commercial Sample computation
- Discussion , Q&A
V CASE STUDY & ASSESSMENT, SUMMARY & RECAP
Reinforcement of Learning : Creating Design Analysis Document 1.5 hr
- Case Study 1 – Residential & Commercial Application
- Case Study 2 – Industrial Application (VD & SC Calculation)
- Case Study 3 – Industrial Plant Application 2MVA ( SC Calculation)
- Preparation of Design Analysis Documents
- OBO requirement for Design Analysis
- Directory of PEE to Sign and Seal Design Analysis
- Discussion , Q&A
TOTAL 9.0 hrs
VI References
1. Philippine Electrical Code 2009 (PEC 1)
2. National Electrical Code 2011 (NFPA 70)
3. IEEE Std 141 – Red Book – Recommended Practice for Electric Power
Distribution for Industrial Plant
4. IEEE Std 551 – Violet Book – Calculating Short Circuit in Industrial and
Commercial Power System
5. DPWH Memorandum Circular No. 02-2015
6. DILG Memorandum Circular No. 23-2016
Prepared by:
Bernabe T. Salazar Jr, PEE
PRC # 0003874, PTR # 0869088E
Issued at Paranaque City
Date Issued: Jan 4, 2017
[email protected][email protected]CP # 09175605339