0% found this document useful (0 votes)
119 views

Ground Floor Plan: Pedro Runolf Diongzon

This document is a recommendation for approval from the Head Fire Protection Section of the Department of Public Works and Highways Office of the Building Official in the Republic of the Philippines. It includes a diagram of a building layout with labels for various fire protection elements (PFE), a main roof line, lower roof line, fire exit doors, and notes regarding a 100Ø DSP (presumably a fire suppression system component). The recommendation is for approval of this building's fire protection system design.

Uploaded by

zacc
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
119 views

Ground Floor Plan: Pedro Runolf Diongzon

This document is a recommendation for approval from the Head Fire Protection Section of the Department of Public Works and Highways Office of the Building Official in the Republic of the Philippines. It includes a diagram of a building layout with labels for various fire protection elements (PFE), a main roof line, lower roof line, fire exit doors, and notes regarding a 100Ø DSP (presumably a fire suppression system component). The recommendation is for approval of this building's fire protection system design.

Uploaded by

zacc
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

REPUBLIC OF THE PHILIPPINES

DEPARTMENT OF PUBLIC WORKS


AND HIGHWAYS
OFFICE OF THE BUILDING OFFICIAL

RECOMMENDING APPROVAL

HEAD FIRE PROTECTION DATE


SECTION
APPROVED:

BUILDING OFFICIAL DATE

FHC FHC DILI MALATA TOXIC


MALATA
PFE 100Ø DSP PFE PFE

WALKWAY

MAIN ROOF LINE

WALKWAY
D1 PFE
Fire Exit Door 1

PFE D3
COOL ROOM

MAIN ROOF LINE

LOWER ROOF LINE


PFE
PFE PFE
100Ø DSP

RECEPTION AREA
V2

WALKWAY
WALKWAY

VEHICLE PARKING AREA


(8 VEHICLES)
OFFICE STORAGE PFE
FHC

Fire Exit Door 2

storage racks

Pantry LOOSE PIECES SECTION


PFE PFE
WAREHOUSE STAFF AREA
PFE

storage racks

storage racks

storage racks

storage racks
CONFERENCE ROOM
Common
Comfort Room
IN BOUND OUT BOUND
OUT BOUND OUT BOUND
OUT BOUND
W.D.
PFE
filing rack

WALKWAY WALKWAY WALKWAY

Ø65 x Ø65 x Ø100 MAIN WAREHOUSE ROOF


Vehicle for IN BOUND Vehicle for OUT BOUND Vehicle for OUT BOUND
DRY STANDPIPE

V1
6.00M LONG SPAN ROOF CANOPY

DRY STAND PIPE SYSTEM @


GROUND FLOOR PLAN

DESIGNED BY THIS DRAWING IS ISSUED FOR :


REG. NO.: 4083 SEAL PROJECT TITLE APPROVED BY SHEET CONTENT SHEET NO. PAGE NO.
DESIGNER AS BUILT ESTIMATE

DATE : 11/14/05 FAST AS SEEN


DRAFTED BY BIDDING FABRICATION

PEDRO RUNOLF DIONGZON PTR NO. : 0742576


FAST-DISTRIBUTION
WAREHOUSE
DISTRIBUTION-CORP.
CAD_OPTR

CAD LT LICENSE: 341-87515783


BUILDING PERMIT

CONSTRUCTION
OWNER'S APPROVAL

PRESENTATION
FP
PROFESSIONAL MECHANICAL ENGINEER OWNER
DATE : 01/8/2020
FOR APPROVAL
2 2
ADDRESS: LAHUG, CEBU TIN : 153-771-376 LOCATION : KORONADAL-CITY ADDRESS : MANDAUE CITY,CEBU REVISIONS DATE